Siemens part number 3RS1441-1HB50 functions as a temperature monitoring relay used to track threshold values across sensitive industrial equipment and trigger protective switching actions.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Temperature monitoring relay
- design of the product: 2 threshold values, digitally adjustable
- product type designation: 3RS14
- General technical data power loss [W] maximum: 4 W
- power loss [V∙A] maximum: 7 VA
- reference code according to IEC 81346-2: K
- ● initial value: -50 °C
- ● full-scale value: 750 °C
- Substance Prohibitance (Date): 05/01/2012
- ● error memory: Yes
- ● external reset: Yes
- design of the sensor connectable: PT100/1000, KTY83/84, NTC (resistance sensors)
- measurable temperature with KTY-sensor maximum: 200 °C
- sensor current with KTY-sensor: 0.3 mA
- Control circuit/ Control type of voltage: DC
- ● at DC rated value: 24 V
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RS1441-1HB50 | |||||||||||||||||||||||||||||||||||||||
| Product Description | temperature monitoring relay for IO-Link Pt100/1000 KTY83/84, NTC 1 to 3 sensors, 2 limit values -50 °C to 750 °C 3 x 1 CO, width 45 mm screw terminal !!!phased-out product!!! the preferred successor is 3RS2800-1BA40+3RS2900-1AA30 | |||||||||||||||||||||||||||||||||||||||
| Product family | Relays, digitally adjustable for up to 3 sensors | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | |||||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 22.02.2021 | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 2 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,333 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 50,00 x 110,00 x 105,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209895942 | |||||||||||||||||||||||||||||||||||||||
| UPC | 040892915594 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5882 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Czech Republic | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 | |||||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001446 - Temperature monitoring relay
| Value | Unit | |
|---|---|---|
| Temperature measuring range (EF009788) | - | °C |
| With detachable clamps (EF003340) | - | |
| Resistance measuring range (EF011955) | - | Ohm |
| Type of electric connection (EF003961) | Screw connection | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '-'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '-'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['18', '30'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Number of measuring circuits (EF003425) | 3 | |
| Error registration possible (EF003423) | true | |
| External reset possible (EF003426) | true | |
| Number of contacts as normally closed contact (EF008255) | 0 | |
| Number of contacts as normally open contact (EF008256) | 0 | |
| Number of contacts as change-over contact (EF008257) | 3 | |
| Width (EF000008) | 45.0 | mm |
| Height (EF000040) | 106.0 | mm |
| Depth (EF000049) | 91.0 | mm |