View larger
3RS1120-1DW20 SIEMENS temperature monitoring relay thermocouple type J, overshoot 2 threshold values, width ..
3RS1120-1DW20
11201
SIEMENS
1 Pcs.
Automation > Temperature monitoring relay
Function relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens temperature monitoring relay thermocouple type J, overshoot 2 threshold values, width .. part number 3RS1120-1DW20 is a protective switching device engineered to supervise thermal limits within electrical panels and industrial machinery. Such relays safeguard sensitive equipment by detecting critical temperature rises via thermocouple sensors and interrupting control circuits before damage occurs. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Temperature monitoring relay
- design of the product: Overshoot, 2 threshold values
- product type designation: 3RS11
- ● initial value: 0 °C
- ● full-scale value: 200 °C
- Substance Prohibitance (Date): 05/01/2012
- ● error memory: No
- ● external reset: No
- design of the sensor connectable: type J (thermocouple)
- Control circuit/ Control type of voltage: AC/DC
- ● at 50 Hz: 24 ... 240 V
- ● at 60 Hz: 24 ... 240 V
- ● at DC: 24 ... 240 V
- supply voltage frequency for auxiliary and control circuit: 50 ... 60 Hz
- number of measuring circuits: 1
- number of NO contacts for auxiliary contacts: 1
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RS1120-1DW20 | |||||||||||||||||||||||||||||||||||||||
| Product Description | temperature monitoring relay thermocouple type J, overshoot 2 threshold values, width 22.5 mm 0 °C to 200 °C 24 - 240 V AC/DC 1 NO + 1 CO, Load and quiescent current screw terminal !!!phased-out product!!! the preferred successor is 3RS2600-1BW30 | |||||||||||||||||||||||||||||||||||||||
| Product family | Relays, analogically adjustable for 1 sensor | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | |||||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,170 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 29,00 x 99,00 x 107,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209536012 | |||||||||||||||||||||||||||||||||||||||
| UPC | 754554870762 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5882 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 | |||||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001446 - Temperature monitoring relay
| Value | Unit | |
|---|---|---|
| Temperature measuring range (EF009788) | - | °C |
| Resistance measuring range (EF011955) | - | Ohm |
| Type of electric connection (EF003961) | Screw connection | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['24', '240'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['24', '240'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['24', '240'] | V |
| Voltage type for actuating (EF008242) | AC/DC | |
| With detachable clamps (EF003340) | true | |
| Number of measuring circuits (EF003425) | 1 | |
| Error registration possible (EF003423) | false | |
| External reset possible (EF003426) | false | |
| Number of contacts as normally closed contact (EF008255) | 0 | |
| Number of contacts as normally open contact (EF008256) | 1 | |
| Number of contacts as change-over contact (EF008257) | 1 | |
| Width (EF000008) | 22.5 | mm |
| Height (EF000040) | 102.0 | mm |
| Depth (EF000049) | 91.0 | mm |