View larger
3RS1100-1CK30 SIEMENS temperature monitoring relay thermocouple type J, overshoot 1 threshold value, width 2..
3RS1100-1CK30
11001
SIEMENS
1 Pcs.
Automation > Temperature monitoring relay
Function relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens 3RS1100-1CK30 is a temperature monitoring relay engineered to process thermocouple inputs and detect thermal threshold overshoots in industrial environments. Such monitoring devices safeguard valuable plant infrastructure by tripping control circuits when operating temperatures surpass safety limits.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Temperature monitoring relay
- design of the product: Overshoot, 1 threshold value
- product type designation: 3RS11
- ● initial value: 0 °C
- ● full-scale value: 600 °C
- Substance Prohibitance (Date): 05/01/2012
- ● error memory: No
- ● external reset: No
- design of the sensor connectable: type J (thermocouple)
- Control circuit/ Control type of voltage: AC
- ● at 50 Hz rated value: 110 V
- ● at 60 Hz rated value: 110 V
- ● at 50 Hz rated value: 230 V
- ● at 60 Hz rated value: 230 V
- supply voltage frequency for auxiliary and control circuit: 50 ... 60 Hz
- number of measuring circuits: 1
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RS1100-1CK30 | |||||||||||||||||||||||||||||||||||||||
| Product Description | temperature monitoring relay thermocouple type J, overshoot 1 threshold value, width 22.5 mm 0 °C to 600 °C 110-120/220-240 V AC 1 NO + 1 NC, quiescent current principle screw terminal !!!phased-out product!!! the preferred successor is 3RS2500-1AW30 | |||||||||||||||||||||||||||||||||||||||
| Product family | Relays, analogically adjustable for 1 sensor | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | |||||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,180 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 29,00 x 99,00 x 107,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209535558 | |||||||||||||||||||||||||||||||||||||||
| UPC | 754554858258 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5882 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 | |||||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001446 - Temperature monitoring relay
| Value | Unit | |
|---|---|---|
| Temperature measuring range (EF009788) | - | °C |
| Resistance measuring range (EF011955) | - | Ohm |
| Type of electric connection (EF003961) | Screw connection | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['110', '230'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['110', '230'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
| Voltage type for actuating (EF008242) | AC | |
| With detachable clamps (EF003340) | true | |
| Number of measuring circuits (EF003425) | 1 | |
| Error registration possible (EF003423) | false | |
| External reset possible (EF003426) | false | |
| Number of contacts as normally closed contact (EF008255) | 1 | |
| Number of contacts as normally open contact (EF008256) | 1 | |
| Number of contacts as change-over contact (EF008257) | 0 | |
| Width (EF000008) | 22.5 | mm |
| Height (EF000040) | 102.0 | mm |
| Depth (EF000049) | 91.0 | mm |



