View larger
3RS1042-2GW70 SIEMENS temperature monitoring relay Pt100/1000 KTY83/84, NTC 2 threshold values digitally adj..
3RS1042-2GW70
10422
SIEMENS
1 Pcs.
Automation > Temperature monitoring relay
Function relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed to safeguard industrial equipment from overheating, the Siemens 3RS1042-2GW70 temperature monitoring relay tracks thermal values received from connected resistance sensors. These relays are regularly installed in electrical switchboards to protect motors, transformers, and bearings from exceeding critical thermal limits. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Temperature monitoring relay
- design of the product: 2 threshold values, digitally adjustable
- product type designation: 3RS10
- General technical data power loss [W] maximum: 4 W
- power loss [V∙A] maximum: 7 VA
- reference code according to IEC 81346-2: K
- ● initial value: -50 °C
- ● full-scale value: 750 °C
- Substance Prohibitance (Date): 05/01/2012
- ● error memory: Yes
- ● external reset: Yes
- design of the sensor connectable: PT100/1000, KTY83/84, NTC (resistance sensors)
- measurable temperature with KTY-sensor maximum: 200 °C
- sensor current with KTY-sensor: 0.3 mA
- Control circuit/ Control type of voltage: AC/DC
- ● at 50 Hz: 24 ... 240 V
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RS1042-2GW70 | ||||||||||||||||||||||||||||||||||||
| Product Description | temperature monitoring relay Pt100/1000 KTY83/84, NTC 2 threshold values digitally adjustable -50 °C to 750 °C (sensor-dependent) 24-240 V AC/DC 2 x 1 CO + 1 NO, width 45 mm spring-loaded connection system !!!phased-out product!!! the preferred successor is 3RS2600-2BW30 | ||||||||||||||||||||||||||||||||||||
| Product family | Relays, digitally adjustable for 1 sensor | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | ||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,285 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 53,00 x 111,50 x 105,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209589810 | ||||||||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364190 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5882 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001446 - Temperature monitoring relay
| Value | Unit | |
|---|---|---|
| Resistance measuring range (EF011955) | - | Ohm |
| Temperature measuring range (EF009788) | - | °C |
| Type of electric connection (EF003961) | Spring clamp connection | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['24', '240'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['24', '240'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['24', '240'] | V |
| Voltage type for actuating (EF008242) | AC/DC | |
| With detachable clamps (EF003340) | true | |
| Number of measuring circuits (EF003425) | 1 | |
| Error registration possible (EF003423) | true | |
| External reset possible (EF003426) | true | |
| Number of contacts as normally closed contact (EF008255) | 0 | |
| Number of contacts as normally open contact (EF008256) | 1 | |
| Number of contacts as change-over contact (EF008257) | 2 | |
| Width (EF000008) | 45.0 | mm |
| Height (EF000040) | 108.0 | mm |
| Depth (EF000049) | 91.0 | mm |