View larger
3RS1030-1DD20 SIEMENS temperature monitoring relay Pt100, undershoot 2 threshold values, width 22.5 mm 0 °C ..
3RS1030-1DD20
10301
SIEMENS
1 Pcs.
Automation > Temperature monitoring relay
Function relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed to prevent thermal anomalies, the Siemens 3RS1030-1DD20 temperature monitoring relay continuously checks resistance sensor signals to protect machinery from overheating or under-temperature conditions. Monitoring relays are standard components in control panels, ensuring system safety by signaling faults when measured values cross critical thresholds.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- product designation: Temperature monitoring relay
- design of the product: Undershoot, 2 threshold values
- product type designation: 3RS10
- General technical data power loss [W] maximum: 2 W
- power loss [V∙A] maximum: 4 VA
- reference code according to IEC 81346-2: K
- ● initial value: 0 °C
- ● full-scale value: 200 °C
- Substance Prohibitance (Date): 05/01/2012
- ● error memory: No
- ● external reset: No
- design of the sensor connectable: PT100 (resistance sensor)
- Control circuit/ Control type of voltage: AC/DC
- ● at 50 Hz rated value: 24 V
- ● at 60 Hz rated value: 24 V
- ● at DC rated value: 24 V
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RS1030-1DD20 | |||||||||||||||||||||||||||||||||||||||
| Product Description | temperature monitoring relay Pt100, undershoot 2 threshold values, width 22.5 mm 0 °C to 200 °C 24 V AC/DC 1 NO + 1 CO, Load and quiescent current screw terminal !!!phased-out product!!! the preferred successor is 3RS2600-1BA30 | |||||||||||||||||||||||||||||||||||||||
| Product family | Relays, analogically adjustable for 1 sensor | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | |||||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,160 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 29,00 x 99,00 x 107,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209535800 | |||||||||||||||||||||||||||||||||||||||
| UPC | 754554870205 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364190 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5882 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 | |||||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001446 - Temperature monitoring relay
| Value | Unit | |
|---|---|---|
| Temperature measuring range (EF009788) | - | °C |
| Resistance measuring range (EF011955) | - | Ohm |
| Type of electric connection (EF003961) | Screw connection | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '24'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '24'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['-', '24'] | V |
| Voltage type for actuating (EF008242) | AC/DC | |
| With detachable clamps (EF003340) | true | |
| Number of measuring circuits (EF003425) | 1 | |
| Error registration possible (EF003423) | false | |
| External reset possible (EF003426) | false | |
| Number of contacts as normally closed contact (EF008255) | 0 | |
| Number of contacts as normally open contact (EF008256) | 1 | |
| Number of contacts as change-over contact (EF008257) | 1 | |
| Width (EF000008) | 22.5 | mm |
| Height (EF000040) | 102.0 | mm |
| Depth (EF000049) | 91.0 | mm |