View larger
3RS1000-1CD20 SIEMENS Temperature monitoring relay PT100, Overshoot 1 threshold value, Width 22.5 mm 0 °C to..
3RS1000-1CD20
10001
SIEMENS
1 Pcs.
Automation > Temperature monitoring relay
Function relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Siemens temperature monitoring relay, part number 3RS1000-1CD20, protects vital plant infrastructure by observing thermal levels in motors, transformers, and industrial assemblies. The unit signals a system response whenever measured temperatures breach configured safety thresholds.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Temperature monitoring relay
- design of the product: Overshoot, 1 threshold value
- product type designation: 3RS10
- General technical data power loss [W] maximum: 2 W
- power loss [V∙A] maximum: 4 VA
- reference code according to IEC 81346-2: K
- initial value: 0 °C
- full-scale value: 200 °C
- Substance Prohibitance (Date): 05/01/2012
- error memory: No
- external reset: No
- design of the sensor connectable: PT100 (resistance sensor)
- Control circuit/ Control type of voltage: AC/DC
- at 50 Hz rated value: 24 V
- at 60 Hz rated value: 24 V
- at DC rated value: 24 V
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RS1000-1CD20 | |||||||||||||||||||||||||||||||||||||||
| Product Description | temperature monitoring relay Pt100, overshoot 1 threshold value, width 22.5 mm 0 °C to 200 °C 24 V AC/DC 1 NO + 1 NC, quiescent current principle screw terminal !!!phased-out product!!! the preferred successor is 3RS2500-1AA30 | |||||||||||||||||||||||||||||||||||||||
| Product family | Relays, analogically adjustable for 1 sensor | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | |||||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,137 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 29,00 x 99,00 x 107,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209535268 | |||||||||||||||||||||||||||||||||||||||
| UPC | 754554869827 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364190 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5882 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 | |||||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001446 - Temperature monitoring relay
| Value | Unit | |
|---|---|---|
| Resistance measuring range (EF011955) | - | Ohm |
| Temperature measuring range (EF009788) | - | °C |
| Type of electric connection (EF003961) | Screw connection | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '24'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '24'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['-', '24'] | V |
| Voltage type for actuating (EF008242) | AC/DC | |
| With detachable clamps (EF003340) | true | |
| Number of measuring circuits (EF003425) | 1 | |
| Error registration possible (EF003423) | false | |
| External reset possible (EF003426) | false | |
| Number of contacts as normally closed contact (EF008255) | 1 | |
| Number of contacts as normally open contact (EF008256) | 1 | |
| Number of contacts as change-over contact (EF008257) | 0 | |
| Width (EF000008) | 22.5 | mm |
| Height (EF000040) | 83.0 | mm |
| Depth (EF000049) | 91.0 | mm |



