View larger
3RR2143-1AA30 SIEMENS Monitoring relay, can be mounted to Contactor 3RT2, Size S2 basic, analog adjustment A..
3RR2143-1AA30
21431
SIEMENS
1 Pcs.
Automation > Current monitoring relay
Thermal relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens part number 3RR2143-1AA30 is a monitoring relay configured for analog current tracking when mounted directly to compatible industrial contactors. Such components form a vital part of safety and diagnostic circuits in modern manufacturing plants, protecting mechanical drives from electrical faults.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- product designation: Monitoring relays
- design of the product: analogically adjustable, 2-phase current monitoring
- product type designation: 3RR2
- operating apparent power rated value: 4 VA
- ● with degree of pollution 3 rated value: 690 V
- surge voltage resistance rated value: 6 kV
- ● on the front: IP20
- ● of the terminal: IP00
- shock resistance: 10g / 11 ms
- vibration resistance: 10 ... 55 Hz / 0.35 mm
- mechanical service life (switching cycles) typical: 10 000 000
- reference code according to IEC 81346-2: K
- relative repeat accuracy: 2 %
- Substance Prohibitance (Date): 03/01/2017
- Supply voltage type of voltage of the supply voltage: AC/DC
- ● at 50 Hz rated value: 24 V
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RR2143-1AA30 | ||||||||||||||||||||||||||||||||||||
| Product Description | Monitoring relay, can be mounted to Contactor 3RT2, Size S2 basic, analog adjustment Apparent current monitoring 8...80 A, 50...60 Hz, 2-phase Supply 24 V AC/DC 1 change-over contact Monitoring for Current overshoot and undershoot Phase failure, Cable break with or without fault buffer ON delay 0-60 s Noise pulse suppression 0-30 s Switching hysteresis 6% Screw connection system | ||||||||||||||||||||||||||||||||||||
| Product family | Current and active current monitoring | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 60 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,200 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 121,00 x 124,00 x 65,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209936225 | ||||||||||||||||||||||||||||||||||||
| UPC | 887621915261 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5343 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Czech Republic | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.03.2017 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001440 - Current monitoring relay
| Value | Unit | |
|---|---|---|
| External current transformer (EF001923) | - | |
| Type of electric connection (EF003961) | Screw connection | |
| With detachable clamps (EF003340) | true | |
| Single-phase under current possible (EF003405) | false | |
| Three-phase under current possible (EF003406) | false | |
| Single-phase over current possible (EF003407) | false | |
| Three-phase over current possible (EF003408) | false | |
| Single-phase hysteresis possible (EF003394) | false | |
| Three-phase hysteresis possible (EF003395) | false | |
| Contains function DC-voltage under current (EF003409) | false | |
| Contains function DC-voltage over current (EF003410) | false | |
| Function DC-current hysteresis (EF003411) | false | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '24'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '24'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['-', '24'] | V |
| Voltage type for actuating (EF008242) | AC/DC | |
| Current measurement range (EF000417) | ['8.0', '80.0'] | A |
| Min. adjustable delay-on energization time (EF008190) | 0 | s |
| Max. permitted delay-on energization time (EF008189) | 60 | s |
| Min. adjustable off-delay time (EF008192) | 0 | s |
| Max. permitted off-delay time (EF008191) | 30 | s |
| Number of contacts as normally closed contact (EF008255) | - | |
| Number of contacts as normally open contact (EF008256) | - | |
| Number of contacts as change-over contact (EF008257) | - | |
| Width (EF000008) | 55.0 | mm |
| Height (EF000040) | 99.0 | mm |
| Depth (EF000049) | 112.0 | mm |