View larger
3RR2141-2AA30 SIEMENS Monitoring relay, can be mounted to Contactor 3RT2, Size S00 basic, analog adjustment ..
3RR2141-2AA30
21412
SIEMENS
1 Pcs.
Automation > Current monitoring relay
Thermal relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Contactor-mounted monitoring relays are specialized electrical components designed to clip directly onto motor control contactors, delivering immediate feedback on current fluctuations without requiring separate panel space. They are widely utilized in motor management systems for overload protection. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Monitoring relays
- design of the product: analogically adjustable, 2-phase current monitoring
- product type designation: 3RR2
- operating apparent power rated value: 4 VA
- ● with degree of pollution 3 rated value: 690 V
- surge voltage resistance rated value: 6 kV
- ● on the front: IP20
- ● of the terminal: IP20
- shock resistance: 15g / 11 ms
- vibration resistance: 10 ... 55 Hz / 0.35 mm
- mechanical service life (switching cycles): 10 000 000
- reference code according to IEC 81346-2: K
- relative repeat accuracy: 2 %
- Substance Prohibitance (Date): 10/01/2009
- Supply voltage type of voltage of the supply voltage: AC/DC
- ● at 50 Hz rated value: 24 V
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RR2141-2AA30 | |||||||||||||||||||||||||||||||||||||||
| Product Description | Monitoring relay, can be mounted to Contactor 3RT2, Size S00 basic, analog adjustment Apparent current monitoring 1.6-16 A, 20-400 Hz, 2-phase Supply 24 V AC/DC 1 change-over contact Monitoring for Current overshoot and undershoot Phase failure, Cable break with or without fault buffer ON delay 0-60 s Noise pulse suppression 0-30 s Switching hysteresis 6% spring-type connection system | |||||||||||||||||||||||||||||||||||||||
| Product family | Current and active current monitoring | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 60 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,228 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 87,00 x 98,00 x 57,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209787315 | |||||||||||||||||||||||||||||||||||||||
| UPC | 662643908589 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5343 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Czech Republic | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2009 | |||||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001440 - Current monitoring relay
| Value | Unit | |
|---|---|---|
| External current transformer (EF001923) | - | |
| Type of electric connection (EF003961) | Spring clamp connection | |
| With detachable clamps (EF003340) | true | |
| Single-phase under current possible (EF003405) | false | |
| Three-phase under current possible (EF003406) | false | |
| Single-phase over current possible (EF003407) | false | |
| Three-phase over current possible (EF003408) | false | |
| Single-phase hysteresis possible (EF003394) | false | |
| Three-phase hysteresis possible (EF003395) | false | |
| Contains function DC-voltage under current (EF003409) | false | |
| Contains function DC-voltage over current (EF003410) | false | |
| Function DC-current hysteresis (EF003411) | false | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '24'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '24'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['-', '24'] | V |
| Voltage type for actuating (EF008242) | AC/DC | |
| Current measurement range (EF000417) | ['1.6', '16.0'] | A |
| Min. adjustable delay-on energization time (EF008190) | 0 | s |
| Max. permitted delay-on energization time (EF008189) | 60 | s |
| Min. adjustable off-delay time (EF008192) | 0 | s |
| Max. permitted off-delay time (EF008191) | 30 | s |
| Number of contacts as normally closed contact (EF008255) | - | |
| Number of contacts as normally open contact (EF008256) | - | |
| Number of contacts as change-over contact (EF008257) | - | |
| Width (EF000008) | 45.0 | mm |
| Height (EF000040) | 90.0 | mm |
| Depth (EF000049) | 80.0 | mm |