View larger
3RN2012-2BA30 SIEMENS Thermistor motor protection relay Standard evaluation unit 22.5 mm enclosure Spring-ty..
3RN2012-2BA30
20122
SIEMENS
1 Pcs.
Automation > Relay for thermistor protection (PTC)
Function relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Protecting critical rotating equipment from thermal overload, the Siemens 3RN2012-2BA30 Thermistor motor protection relay Standard evaluation unit 22.5 mm enclosure Spring-ty. continuously evaluates embedded PTC temperature sensors inside motor windings. Such monitoring devices are widely deployed in manufacturing plants and automated production lines to prevent catastrophic motor failure caused by overheating or blocked ventilation. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product category: SIRIUS 3RN2 thermistor motor protection
- product designation: Thermistor motor protection relay
- product type designation: 3RN2
- General technical data product function: thermistor motor protection
- display version LED: Yes
- degree of pollution: 3
- surge voltage resistance rated value: 4 kV
- protection class IP: IP20
- shock resistance according to IEC 60068-2-27: 11g / 15 ms
- vibration resistance according to IEC 60068-2-6: 10 ... 55 Hz: 0.35 mm
- mechanical service life (switching cycles) typical: 10 000 000
- reference code according to IEC 81346-2: K
- Substance Prohibitance (Date): 05/28/2009
- ● error memory: Yes
- ● dynamic open-circuit detection: Yes
- ● external reset: Yes
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RN2012-2BA30 | ||||||||||||||||||||||||||||||||||||
| Product Description | Thermistor motor protection relay Standard evaluation unit 22.5 mm enclosure Spring-type terminal 2 change-over contacts US = 24 V AC/DC Manual/Auto/Remote reset with ATEX approval 2 LEDs (READY/TRIPPED) galvanic isolation Test/reset button Wire break monitoring Short circuit monitoring non-volatile | ||||||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RN2 thermistor motor protection | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,178 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 37,00 x 111,00 x 129,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4047621006659 | ||||||||||||||||||||||||||||||||||||
| UPC | 804766415609 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 4953 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 28.05.2009 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC002568 - Relay for thermistor protection (PTC)
| Value | Unit | |
|---|---|---|
| Rated control supply voltage Us (EF002412) | - | V |
| Connection type auxiliary circuit (EF006820) | - | |
| With detachable clamps (EF003340) | - | |
| Voltage type for actuating (EF008242) | - | |
| Number of measuring circuits (EF003425) | 1 | |
| Number of contacts as normally closed contact (EF008255) | 0 | |
| Number of contacts as normally open contact (EF008256) | 0 | |
| Number of contacts as change-over contact (EF008257) | 2 | |
| External reset possible (EF003426) | true | |
| Error registration possible (EF003423) | true | |
| Height (EF000040) | 100.0 | mm |
| Width (EF000008) | 22.5 | mm |
| Depth (EF000049) | 90.0 | mm |