View larger
3RM1202-3AA14 SIEMENS Reversing starter, 3RM1, 500 V, 0.09 0.75 kW, 0.4 2 A, 110-230 V AC, screw/spring-type..
3RM1202-3AA14
12023
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
Contactors for switching motors
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Siemens 3RM1202-3AA14 Reversing starter, 3RM1, 500 V, 0.09 0.75 kW, 0.4 2 A, 110-230 V AC, screw/spring-type.. is a modular solid-state switching device designed for reversing three-phase loads. Reversing starters are standard components in industrial automation used to invert motor rotation for material handling and processing equipment. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product category: Motor starter
- product designation: Reversing starter
- design of the product: with electronic overload protection
- product type designation: 3RM1
- General technical data trip class: CLASS 10A
- equipment variant according to IEC 60947-4-2: 3
- product function: Reversing starter
- ● intrinsic device protection: Yes
- ● for power supply reverse polarity protection: No
- suitability for operation device connector 3ZY12: No
- insulation voltage rated value: 500 V
- overvoltage category: III
- surge voltage resistance rated value: 6 kV
- ● between main and auxiliary circuit: 500 V
- ● between control and auxiliary circuit: 250 V
- shock resistance: 6g / 11 ms
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RM1202-3AA14 | |||||||||||||||||||||||||||||||||
| Product Description | Reversing starter, 3RM1, 500 V, 0.09 - 0.75 kW, 0.4 - 2 A, 110-230 V AC, screw/spring-type terminals | |||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RM1 motor starters | |||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41D / 41D | |||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||
| Metal Factor | None | |||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||
| Standard lead time ex-works | On request | |||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,325 Kg | |||||||||||||||||||||||||||||||||
| Packaging Dimension | 36,00 x 109,00 x 167,00 | |||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||
| EAN | 4011209935914 | |||||||||||||||||||||||||||||||||
| UPC | 887621293864 | |||||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | |||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||
| Product Group | 3762 | |||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.03.2017 | |||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Type of motor starter (EF009598) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Number of indicator lights (EF001965) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Coordination class according to IEC 60947-4-3 (EF012390) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Supporting protocol for Modbus (EF003057) | - | |
| Rail mounting possible (EF003972) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Supporting protocol for ASI (EF003051) | - | |
| With short-circuit release (EF006691) | false | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['110', '230'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['110', '230'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['110', '110'] | V |
| Voltage type for actuating (EF008242) | AC/DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 0.75 | kW |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | 0.551624063 | kW |
| Rated operation current Ie (EF001443) | 2 | A |
| Overload release current setting (EF002336) | ['2', '2'] | A |
| Release class (EF006668) | CLASS 10 A | |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Other | |
| With transformer (EF000278) | false | |
| Number of command positions (EF001372) | 0 | |
| With fuse (EF006693) | false | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Width (EF000008) | 22.5 | mm |
| Height (EF000040) | 100.0 | mm |
| Depth (EF000049) | 141.6 | mm |