View larger
3RM1001-1AA04 SIEMENS Direct starter, 3RM1, 500 V, 0 0.12 kW, 0.1 0.5 A, 24 V DC, screw terminals
3RM1001-1AA04
10011
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
Contactors for switching motors
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Direct starter 3RM11001-1AA04 by Siemens functions as a direct-on-line motor starter equipped with integrated electronic overload protection for industrial automation switchgear panels. Motor starters safely manage electrical power distribution, start and stop industrial motors, and protect connected machinery against phase loss and thermal overload conditions during continuous operation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product category: Motor starter
- product designation: Direct-on-line starter
- design of the product: with electronic overload protection
- product type designation: 3RM1
- General technical data trip class: CLASS 10A
- equipment variant according to IEC 60947-4-2: 3
- product function: Direct-on-line starter
- intrinsic device protection: Yes
- for power supply reverse polarity protection: No
- suitability for operation device connector 3ZY12: Yes
- insulation voltage rated value: 500 V
- overvoltage category: III
- surge voltage resistance rated value: 6 kV
- between main and auxiliary circuit: 500 V
- between control and auxiliary circuit: 250 V
- shock resistance: 6g / 11 ms
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RM1001-1AA04 | ||||||||||||||||||||||||||||||||||||
| Product Description | Direct starter, 3RM1, 500 V, 0 - 0.12 kW, 0.1 - 0.5 A, 24 V DC, screw terminals | ||||||||||||||||||||||||||||||||||||
| Product family | Ordering Data Overview | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41D / 41D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | None | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 120 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,315 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 36,00 x 109,00 x 167,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209914681 | ||||||||||||||||||||||||||||||||||||
| UPC | 887621167899 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 3762 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.03.2017 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Coordination class according to IEC 60947-4-3 (EF012390) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Type of motor starter (EF009598) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for ASI (EF003051) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Rail mounting possible (EF003972) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Number of indicator lights (EF001965) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| With short-circuit release (EF006691) | false | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '-'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '-'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['24', '24'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 0.12 | kW |
| Rated operation current Ie (EF001443) | 0.5 | A |
| Overload release current setting (EF002336) | ['0.5', '0.5'] | A |
| Release class (EF006668) | CLASS 10 A | |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Screw connection | |
| With transformer (EF000278) | false | |
| Number of command positions (EF001372) | 0 | |
| With fuse (EF006693) | false | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Width (EF000008) | 22.5 | mm |
| Height (EF000040) | 100.0 | mm |
| Depth (EF000049) | 141.6 | mm |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |