View larger
3RK3122-1AC00 SIEMENS SIRIUS, Central unit 3RK3 ASIsafe Extended for modular Safety system 3RK3 2/4 F-DI, 4 ..
3RK3122-1AC00
31221
SIEMENS
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Programmable safety relays MSS
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Modular Safety System functioning as a Siemens 3RK3122-1AC00 central unit, designed to coordinate functional safety logic and safety-related signals within complex automated machinery. Central control units of this nature are deployed in industrial environments to process signals from emergency stop buttons, light curtains, and safety interlocks, safely interrupting power to hazardous equipment when a fault or breach is detected.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product category: Modular Safety System
- product designation: Central unit
- design of the product: 2/4 F-DI, 4 DI, 1 F-RO, 1 F-DO
- ● EMERGENCY STOP function: Yes
- ● protective door monitoring: Yes
- ● protective door monitoring with tumbler: Yes
- ● muting, 2 sensor-parallel: Yes
- ● muting, 4 sensor-parallel: Yes
- ● muting, 4 sensor-sequential: Yes
- ● monitoring parameterizable: Yes
- ● evaluation: electro-sensitive protective equipment: Yes
- ● evaluation: selector switch: Yes
- ● pressure-sensitive mat monitoring: Yes
- ● evaluation: two-hand operator panel: Yes
- ● evaluation: enabling switch: Yes
- ● monitored start-up: Yes
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK3122-1AC00 | |||||||||||||||||||||||||||||||||||||||
| Product Description | SIRIUS, Central unit 3RK3 ASIsafe Extended for modular Safety system 3RK3 2/4 F-DI, 4 DI, 1 F-RO, 1 F-DO,24 V DC Monitoring of ASI slaves Control of 10 safe outputs on AS-Interface bus parameterizable using software Safety ES 45 mm width screw terminal Up to SIL3 (IEC 61508) Up to Performance Level E (ISO 13849-1) 2 extension modules connectable | |||||||||||||||||||||||||||||||||||||||
| Product family | 3RK31 central units | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | |||||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2021 | |||||||||||||||||||||||||||||||||||||||
| Notes | Sucessor:successor 3SK2, S7-1200F or ET200SP when AS-i is used | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42B / 42B | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | None | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 15 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,360 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 52,50 x 133,00 x 133,00 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209913233 | |||||||||||||||||||||||||||||||||||||||
| UPC | 887621034320 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5358 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 28.05.2009 | |||||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001449 - Device for monitoring of safety-related circuits
| Value | Unit | |
|---|---|---|
| Model (EF000010) | - | |
| Release-delay (EF001129) | - | s |
| Type of safety according to IEC 61496-1 (EF004105) | - | |
| SIL according to IEC 61508 (EF009889) | - | |
| Evaluation inputs (EF008245) | - | |
| Performance level according to EN ISO 13849-1 (EF007399) | - | |
| Suitable for monitoring of position switches (EF007270) | true | |
| Suitable for monitoring of emergency-stop circuits (EF007268) | true | |
| Suitable for monitoring of valves (EF007272) | true | |
| Suitable for monitoring of optoelectronic protection equipment (EF007269) | true | |
| Suitable for monitoring of tactile sensors (EF007271) | - | |
| Suitable for monitoring of magnetic switches (EF007266) | - | |
| Suitable for monitoring of proximity switches (EF007267) | true | |
| Type of electric connection (EF003961) | Screw connection | |
| Rail mounting possible (EF003972) | FALSE | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '-'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '-'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['24', '24'] | V |
| Voltage type for actuating (EF008242) | DC | |
| With detachable clamps (EF003340) | true | |
| With start input (EF003342) | - | |
| With muting function (EF004057) | false | |
| With feedback circuit (EF003343) | - | |
| Number of outputs, safety related, undelayed, with contact (EF003344) | 0 | |
| Number of outputs, safety related, delayed, with contact (EF003345) | - | |
| Number of outputs, safety related, undelayed, semiconductors (EF003346) | 1 | |
| Number of outputs, safety related, delayed, semiconductors (EF003347) | - | |
| Number of outputs, signalling function, undelayed, with contact (EF003348) | - | |
| Number of outputs, signalling function, delayed, with contact (EF003349) | - | |
| Number of outputs, signalling function, undelayed, semiconductors (EF003350) | - | |
| Number of outputs, signalling function, delayed, semiconductors (EF003351) | - | |
| Category according to EN 954-1 (EF006782) | 4 | |
| Stop category according to IEC 60204 (EF007498) | 0 + 1 | |
| With approval for TÜV (EF004144) | true | |
| With approval for BG BIA (EF004145) | - | |
| With approval according to UL (EF001783) | true | |
| Width (EF000008) | 45.0 | mm |
| Height (EF000040) | 111.0 | mm |
| Depth (EF000049) | 124.0 | mm |