Request QuoteProduct Overview
A Siemens 3RK1908-0AP00-0AP0 base unit acts as a structural mounting and power distribution foundation for modular ET 200SP motor starter assemblies in industrial control architectures. Base units provide the necessary internal bus connections and terminal interfaces to distribute control voltages and main power safely across distributed I/O setups. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product category: Accessories
- product designation: BaseUnit
- design of the product: For AC/DC feed in
- product type designation: ET 200SP
- General technical data insulation voltage rated value: 500 V
- degree of pollution: 2
- surge voltage resistance rated value: 6 kV
- ● between main and auxiliary circuit: 500 V
- shock resistance: 6g / 11 ms
- vibration resistance: 15 mm to 6 Hz; 2g to 500 Hz
- reference code according to IEC 81346-2: Q
- Substance Prohibitance (Date): 04/15/2016
- touch protection on the front according to IEC 60529: finger-safe
- Main circuit number of poles for main current circuit: 3
- type of voltage of the operating voltage: 3
- operating voltage rated value: 500 V
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1908-0AP00-0AP0 | ||||||||||||||||||||||||||||||
| Product Description | Base unit (BU30-MS1) For ET 200SP motor starter With infeed 24 V and 500 V Incl. infeed bus cover | ||||||||||||||||||||||||||||||
| Product family | ET 200SP motor starters | ||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||
| Metal Factor | None | ||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||
| Standard lead time ex-works | 30 Day/Days | ||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,170 Kg | ||||||||||||||||||||||||||||||
| Packaging Dimension | 57,00 x 219,00 x 86,00 | ||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||
| EAN | 4047621021300 | ||||||||||||||||||||||||||||||
| UPC | 804766246944 | ||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | ||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||
| Product Group | 3724 | ||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||
| Country of origin | Czech Republic | ||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 15.04.2016 | ||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Supporting protocol for ASI (EF003051) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Number of indicator lights (EF001965) | - | |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Number of command positions (EF001372) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at DC (EF003980) | - | V |
| With fuse (EF006693) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Rated operation power at AC-3, 400 V (EF001364) | - | kW |
| Overload release current setting (EF002336) | - | A |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| External reset possible (EF003426) | - | |
| Release class (EF006668) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Coordination class according to IEC 60947-4-3 (EF012390) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Rail mounting possible (EF003972) | - | |
| With short-circuit release (EF006691) | - | |
| Type of motor starter (EF009598) | Other | |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation current Ie (EF001443) | 32 | A |
| Type of electrical connection of main circuit (EF006819) | Other | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Other | |
| With transformer (EF000278) | false | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Width (EF000008) | 30.0 | mm |
| Height (EF000040) | 215.0 | mm |
| Depth (EF000049) | 75.0 | mm |