SIEMENS 3RK1902-1GC10 3RK1902-1GC10 SIEMENS Bus cable for PROFIBUS Pre-assembled at one end 1 x M12 angled, pin 2-core, shielded L.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

3RK1902-1GC10 SIEMENS Bus cable for PROFIBUS Pre-assembled at one end 1 x M12 angled, pin 2-core, shielded L..

3RK1902-1GC10

19021

SIEMENS

1 Pcs.

Bus cable for PROFIBUS Pre-assembled at one end 1 x M12 angled, pin 2-core, shielded Length 10 m BUS CABLE FOR PROFIBUS PREASSEMBLED ONE SIDE 1XM12 ANGLED, MALE 3-CORE, SHIELDED LENGTH 10M.

Cables > Data and communication cable
AS-Interface switchgear, SIMOCODE

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Bus cable for PROFIBUS Pre-assembled at one end 1 x M12 angled, pin 2-core, shielded Length 10 m
General technical data
product descriptionM12 socket, angled B coded
wire lengthm10
cable designationBUS: 1P24-19/2,55 02YS(ST)C11Y
General technical data
ampacity per pin maximumA4
operating voltage
● at DC maximumV60
● at AC maximumV60
surge voltage resistance rated valuekV1.5
impedance
● at 9.6 kHz300
● at 38.4 kHz185
● at 3 MHz … 20 MHz150
symmetrical tolerance of wave impedance
● at 38.4 kHz20
● at 3 MHz … 20 MHz15
attenuation factor per length
● at 9.6 kHz maximumdB/km3
● at 38.4 kHz maximumdB/km5
● at 4 MHz maximumdB/km26
● at 16 MHz maximumdB/km52
Mechanical data
connector typeSocket/open
connector coding of the M12 circular connectorB
number of electrical cores2
type of cable outletangled
number of poles2
color
● of cable sheathViolet
● of the insulation of data wiresRed, green
material
● of cable sheathPolyurethane
● of the wire insulationPolyethylene
● of the enclosureThermoplastic polyurethane
design of the shieldShielding braid of tinned copper wire
type of strain reliefmolded
bending radius
● with single bend minimum permissiblemm58.5
● with multiple bends minimum permissiblemm78
number of bending cycles5 000 000
mechanical service life (mating cycles)100
outer diameter
● of inner conductormm0.64
● of the cablemm7.8
symmetrical tolerance of the outer diameter of the cablemm0.2
conductor cross section rated valuemm²0.25
type of plug interlockM12 x 1 thread
cable end componentsopen on one side
Ambient conditions
chemical resistance
● to mineral oilconditional, must be checked relative to the application
● to waterconditional, must be checked relative to the application
● to greaseconditional, must be checked relative to the application
degree of pollution3
Certificates/ approvals
certificate of suitability
● CSA approvalYes
● RoHS conformityYes
● UL approvalYes
● CCCNo
● IEC approvalYes
● cUL approvalNo

Downloads and manuals

● C-TickNo
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
last modified:12/8/2021
Date
5/4/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RK1902-1GC10
Product DescriptionBus cable for PROFIBUS Pre-assembled at one end 1 x M12 angled, pin 2-core, shielded Length 10 m
Product familyAccessories for all M200D motor starters
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group42D / 42D
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works15 Day/Days
Net Weight (kg)0,726 Kg
Packaging Dimension270,00 x 290,00 x 50,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209854376
UPC662643851304
Commodity Code85444290
LKZ_FDB/ CatalogIDCC-IC10
Product Group3722
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
VersionClassification
eClass627-06-18-01
eClass7.127-06-18-01
eClass827-06-18-01
eClass927-06-18-01
eClass9.127-06-18-01
ETIM5EC000830
ETIM6EC000830
ETIM7EC003249
ETIM8EC003249
IDEA41722
UNSPSC1439-12-15-21
UNSPSC1526-12-16-09

ETIM data

ETIM: EC003249 - Data and communication cable

Value Unit
Halogen free (according to EN 60754-1/2) (EF009769) -
Euro class acidity according to EN 13501-6 (EF011580) -
Conductor surface (EF010804) -
Armouring (EF001024) -
Screen over stranding (EF001624) -
Conductor category (EF001632) -
Stranding (EF003802) -
Oil resistant (according to EN 60811-404) (EF009770) -
Smoke development class according to EN 13501-6 (EF011578) -
Min. permitted bending radius, moving application/free movement (EF011802) -mm
Material core insulation (EF000061) -
Material outer sheath (EF001625) -
Reaction-to-fire class according to EN 13501-6 (EF011577) -
Min. permitted bending radius, moving application with forced guidance (EF011801) -mm
Min. permitted bending radius, stationary application/permanent installation (EF011803) -mm
Flame retardant (EF000471) -
Circuit integrity (EF001613) -
Number of stranding elements (EF001688) -
Nominal cross section conductor (EF000060) -mm²
Colour outer sheath (EF001618) -
Permitted cable outer temperature after assembling without vibration (EF001686) -°C
AWG-size (EF001692) -
Halogen free (according to IEC 60754-2) (EF003792) -
Outer diameter approx. (EF003921) -mm
Low smoke (according to BS EN 61034-2) (EF008027) -
Longitudinal water blocking cable (EF011011) -
Category (EF001619) -
Low smoke (according to IEC 61034-2) (EF003799) -
UV resistant (EF000024) -
Core identification (EF000067) -
Permitted cable outer temperature during assembling/handling (EF001685) -°C
Specification core insulation (EF011805) -
Stranding element (EF001617) -
Screen over stranding element (EF001623) -
Protective sheath (EF001691) -
Insulation integrity according to IEC 60331 (EF003794) -
Radial water blocking cable (EF011012) -
Specification material outer sheath (EF011806) -
Diameter conductor (EF001621) -mm
Number of cores (EF001792) -
Suitable for underground installation (EF003689) -
NVP value (EF008387) -%
Oil resistant (according to IEC 60811-404) (EF009842) -
Euro class flaming droplets/particles according to EN 13501-6 (EF011579) -



Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.