Request QuoteProduct Overview
Siemens 3RK1395-6KS41-3AD5 motor starter module delivers decentralized drive control for automated conveyor networks and distributed industrial machinery, featuring robust reversing capabilities and high environmental ingress protection. These modules mount directly onto machinery to reduce cabinet wiring complexity. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Motor starters
- design of the product: reversing starter
- product type designation: M200D
- trip class: CLASS 5, 10, 15, 20
- ● on-site operation: Yes
- ● control circuit interface to parallel wiring: No
- insulation voltage rated value: 500 V
- degree of pollution: 3
- surge voltage resistance rated value: 6 000 V
- ● between main and auxiliary circuit: 400 V
- ● between control and auxiliary circuit: 24 V
- protection class IP: IP65
- shock resistance: 12g / 11 ms
- vibration resistance: 7 mm / 2g
- type of assignment: 2
- certificate of suitability: CE
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1395-6KS41-3AD5 | ||||||||||||||||||||||||||||||||||||
| Product Description | SIRIUS motor starter M200D Technology module Reversing starter Mechanical switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC with brake contact 180 V DC 4 DI / 2 DO Han Q4/2 - Han Q8/0 with manual on-site operation and key-operated switch via communication module 3RK1305* can be used on PROFIBUS or PROFINET | ||||||||||||||||||||||||||||||||||||
| Product family | M200D motor starter modules | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 15 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 4,000 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 287,00 x 377,00 x 221,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209824034 | ||||||||||||||||||||||||||||||||||||
| UPC | 662643544541 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 3722 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Supporting protocol for Data-Highway (EF003058) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| With fuse (EF006693) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Number of command positions (EF001372) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Number of indicator lights (EF001965) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| External reset possible (EF003426) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Rail mounting possible (EF003972) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Type of motor starter (EF009598) | Reversing starter | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '-'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '-'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['20.4', '28.8'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 0.75 | kW |
| Rated operation current Ie (EF001443) | 2 | A |
| Rated operation current at AC-3, 400 V (EF009602) | 2 | A |
| Overload release current setting (EF002336) | ['0.15', '2'] | A |
| Release class (EF006668) | Other | |
| Type of electrical connection of main circuit (EF006819) | Other | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Other | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
| Degree of protection (IP) (EF005474) | IP65 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 294.0 | mm |
| Height (EF000040) | 215.0 | mm |
| Depth (EF000049) | 148.0 | mm |