View larger
3RK1315-6LS41-1AA5 SIEMENS SIRIUS motor starter M200D AS-i Communication: AS-Interface Reversing starter Bas..
3RK1315-6LS41-1AA5
13156
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
AS-Interface switchgear, SIMOCODE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The 3RK1315-6LS41-1AA5 SIEMENS SIRIUS motor starter M200D AS-i Communication: AS-Interface Reversing starter Bas.. functions as a distributed reversing motor starter equipped with AS-Interface communication for decentralized machine control architectures. Decentralized M200D starters streamline cabinet-free system concepts by mounting directly on industrial machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Motor starters
- design of the product: reversing starter
- product type designation: M200D
- trip class: CLASS 10
- ● on-site operation: No
- ● control circuit interface to parallel wiring: No
- insulation voltage rated value: 500 V
- degree of pollution: 3
- surge voltage resistance rated value: 6 000 V
- ● between main and auxiliary circuit: 400 V
- ● between control and auxiliary circuit: 24 V
- protection class IP: IP65
- shock resistance: 12g / 11 ms
- vibration resistance: 7 mm / 2g
- type of assignment: 1
- certificate of suitability: CE
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1315-6LS41-1AA5 | ||||||||||||||||||||||||||||||||||||
| Product Description | SIRIUS motor starter M200D AS-i Communication: AS-Interface Reversing starter Basic Mechanical switching AC-3, 5.5 kW / 400 V 1.5 A...12.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC with brake contact 180 V DC 2DI AS-i + 2DI / 1DO on device Han Q4/2 - Han Q8/0 | ||||||||||||||||||||||||||||||||||||
| Product family | M200D Basic motor starters | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 100 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 3,908 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 287,00 x 377,00 x 221,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209823266 | ||||||||||||||||||||||||||||||||||||
| UPC | 662643544138 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 3722 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Number of command positions (EF001372) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Rail mounting possible (EF003972) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Number of indicator lights (EF001965) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| With fuse (EF006693) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Type of motor starter (EF009598) | Reversing starter | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '-'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '-'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['20.4', '28.8'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 5.5 | kW |
| Rated operation current Ie (EF001443) | 12 | A |
| Rated operation current at AC-3, 400 V (EF009602) | 12 | A |
| Overload release current setting (EF002336) | ['1.5', '12'] | A |
| Release class (EF006668) | CLASS 10 | |
| Type of electrical connection of main circuit (EF006819) | Other | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Other | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 1 | |
| Degree of protection (IP) (EF005474) | IP65 | |
| Supporting protocol for ASI (EF003051) | true | |
| Width (EF000008) | 294.0 | mm |
| Height (EF000040) | 215.0 | mm |
| Depth (EF000049) | 159.0 | mm |