View larger
3RK1308-0DE00-0CP0 SIEMENS Failsafe reversing starter High Feature Incl. fan (3RW4928-8VB00) Electronic swit..
3RK1308-0DE00-0CP0
13080
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
AS-Interface switchgear, SIMOCODE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens 3RK1308-0DE00-0CP0 is a failsafe reversing starter from the ET 200SP series, offering advanced electronic switching for decentralized automation. Motor starters of this classification handle complex operational logic and safety routines.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product category: Motor starter
- product designation: Reversing starter
- product type designation: ET 200SP
- General technical data trip class: CLASS OFF / 5 / 10 adjustable
- equipment variant according to IEC 60947-4-2: 3
- product function: Fail-safe reversing starter
- ● on-site operation: Yes
- ● intrinsic device protection: Yes
- ● remote firmware update: Yes
- ● for power supply reverse polarity protection: Yes
- insulation voltage rated value: 500 V
- degree of pollution: 2
- overvoltage category: III
- surge voltage resistance rated value: 6 kV
- ● between main and auxiliary circuit: 500 V
- shock resistance: 6g / 11 ms
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1308-0DE00-0CP0 | ||||||||||||||||||||||||||||||
| Product Description | Failsafe reversing starter High Feature; Incl. fan (3RW4928-8VB00); Electronic switching; Electronic overload protection up to 5.5 kW / 400 V; Adjustment range 4.0 .. 12 A; PROFIenergy; Option: 3DI/LC module | ||||||||||||||||||||||||||||||
| Product family | ET 200SP motor starters | ||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||
| Metal Factor | None | ||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||
| Standard lead time ex-works | 60 Day/Days | ||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,603 Kg | ||||||||||||||||||||||||||||||
| Packaging Dimension | 103,00 x 187,00 x 172,00 | ||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||
| EAN | 4047621031552 | ||||||||||||||||||||||||||||||
| UPC | 804766464379 | ||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | ||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||
| Product Group | 3724 | ||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 15.04.2016 | ||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Supporting protocol for DeviceNet (EF003059) | - | |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Type of electrical connection of main circuit (EF006819) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Type of motor starter (EF009598) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Rail mounting possible (EF003972) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Number of indicator lights (EF001965) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Number of command positions (EF001372) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| External reset possible (EF003426) | - | |
| With fuse (EF006693) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Supporting protocol for LON (EF003017) | - | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation current Ie (EF001443) | 12 | A |
| Overload release current setting (EF002336) | ['4', '12'] | A |
| Release class (EF006668) | Other | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 1 | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 30.0 | mm |
| Height (EF000040) | 142.0 | mm |
| Depth (EF000049) | 150.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |
| Rated operation power at AC-3, 400 V (EF001364) | - | kW |