View larger
3RK1308-0DC00-0CP0 SIEMENS Failsafe reversing starter High Feature Electronic switching electronic overload ..
3RK1308-0DC00-0CP0
13080
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
AS-Interface switchgear, SIMOCODE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens failsafe reversing starter 3RK1308-0DC00-0CP0 from the ET 200SP series delivers advanced electronic switching and comprehensive motor protection for automated manufacturing lines. Electronic motor starters provide precise control, integrated diagnostics, and safety functions for complex industrial networks.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- product category: Motor starter
- product designation: Reversing starter
- product type designation: ET 200SP
- General technical data trip class: CLASS OFF / 5 / 10 adjustable
- equipment variant according to IEC 60947-4-2: 3
- product function: Fail-safe reversing starter
- ● on-site operation: Yes
- ● intrinsic device protection: Yes
- ● remote firmware update: Yes
- ● for power supply reverse polarity protection: Yes
- insulation voltage rated value: 500 V
- degree of pollution: 2
- overvoltage category: III
- surge voltage resistance rated value: 6 kV
- ● between main and auxiliary circuit: 500 V
- shock resistance: 6g / 11 ms
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1308-0DC00-0CP0 | |||||||||||||||||||||||||||||||||
| Product Description | Failsafe reversing starter High Feature; Electronic switching; electronic overload protection up to 1.1 kW / 400 V; Adjustment range 0.9 .. 3 A; PROFIenergy; option: 3DI/LC module | |||||||||||||||||||||||||||||||||
| Product family | ET 200SP motor starters | |||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | |||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||
| Metal Factor | None | |||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | |||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 40 Day/Days | |||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,550 Kg | |||||||||||||||||||||||||||||||||
| Packaging Dimension | 103,00 x 183,00 x 170,00 | |||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||
| EAN | 4047621012285 | |||||||||||||||||||||||||||||||||
| UPC | 804766414367 | |||||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | |||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||
| Product Group | 3724 | |||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 15.04.2016 | |||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Suitable for emergency stop (EF001433) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Number of indicator lights (EF001965) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Type of electrical connection of main circuit (EF006819) | - | |
| Number of command positions (EF001372) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| With fuse (EF006693) | - | |
| Type of motor starter (EF009598) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Rail mounting possible (EF003972) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation current Ie (EF001443) | 3 | A |
| Overload release current setting (EF002336) | ['0.9', '3'] | A |
| Release class (EF006668) | Other | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 1 | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 30.0 | mm |
| Height (EF000040) | 142.0 | mm |
| Depth (EF000049) | 150.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |
| Rated operation power at AC-3, 400 V (EF001364) | - | kW |