View larger
3RK1308-0CC00-0CP0 SIEMENS Fail-safe direct-on-line starter High Feature Electronic switching Electronic ove..
3RK1308-0CC00-0CP0
13080
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
AS-Interface switchgear, SIMOCODE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Fail-safe direct-on-line starter 3RK1308-0CC00-0CP0 from Siemens provides secure electronic switching and overload protection within distributed ET 200SP modular automation architectures. Safety-integrated motor starters combine standard drive control with functional safety protocols to safely disconnect power to machinery in emergency stop scenarios.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product category: Motor starter
- product designation: Direct-on-line starter
- product type designation: ET 200SP
- General technical data trip class: CLASS OFF / 5 / 10 adjustable
- equipment variant according to IEC 60947-4-2: 3
- product function: Fail-safe direct-on-line starter
- on-site operation: Yes
- intrinsic device protection: Yes
- remote firmware update: Yes
- for power supply reverse polarity protection: Yes
- insulation voltage rated value: 500 V
- degree of pollution: 2
- overvoltage category: III
- surge voltage resistance rated value: 6 kV
- between main and auxiliary circuit: 500 V
- shock resistance: 6g / 11 ms
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1308-0CC00-0CP0 | |||||||||||||||||||||||||||||||||
| Product Description | Fail-safe direct-on-line starter High Feature; Electronic switching; Electronic overload protection up to 1.1 kW / 400 V; Adjustment range 0.9 .. 3 A; PROFIenergy; Option: 3DI/LC module | |||||||||||||||||||||||||||||||||
| Product family | ET 200SP motor starters | |||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | |||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||
| Metal Factor | None | |||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | |||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 20 Day/Days | |||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,547 Kg | |||||||||||||||||||||||||||||||||
| Packaging Dimension | 184,00 x 171,00 x 76,00 | |||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||
| EAN | 4047621012261 | |||||||||||||||||||||||||||||||||
| UPC | 804766464324 | |||||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | |||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||
| Product Group | 3724 | |||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 15.04.2016 | |||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Type of motor starter (EF009598) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Rail mounting possible (EF003972) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Number of command positions (EF001372) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Type of electrical connection of main circuit (EF006819) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Degree of protection (NEMA) (EF011959) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Number of indicator lights (EF001965) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| With fuse (EF006693) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Temperature compensated overload protection (EF009604) | - | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation current Ie (EF001443) | 3 | A |
| Overload release current setting (EF002336) | ['0.9', '3'] | A |
| Release class (EF006668) | Other | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 1 | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 30.0 | mm |
| Height (EF000040) | 142.0 | mm |
| Depth (EF000049) | 150.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |
| Rated operation power at AC-3, 400 V (EF001364) | - | kW |











