View larger
3RK1308-0BC00-0CP0 SIEMENS Reversing starter High Feature Electronic switching Electronic overload protectio..
3RK1308-0BC00-0CP0
13080
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
AS-Interface switchgear, SIMOCODE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Siemens 3RK1308-0BC00-0CP0 reversing starter is a modular electronic switching device built for integration into distributed control systems to govern motor direction and protection. These units are commonly deployed in conveyor systems, automated handling equipment, and process machinery where bi-directional motor control is required. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product category: Motor starter
- product designation: Reversing starter
- product type designation: ET 200SP
- General technical data trip class: CLASS OFF / 5 / 10 adjustable
- equipment variant according to IEC 60947-4-2: 3
- product function: Reversing starter
- ● on-site operation: Yes
- ● intrinsic device protection: Yes
- ● remote firmware update: Yes
- ● for power supply reverse polarity protection: Yes
- insulation voltage rated value: 500 V
- degree of pollution: 2
- overvoltage category: III
- surge voltage resistance rated value: 6 kV
- ● between main and auxiliary circuit: 500 V
- shock resistance: 6g / 11 ms
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1308-0BC00-0CP0 | |||||||||||||||||||||||||||||||||
| Product Description | Reversing starter High Feature; Electronic switching; Electronic overload protection up to 1.1 kW / 400 V; Adjustment range 0.9 .. 3 A; PROFIenergy; Option: 3DI/LC module | |||||||||||||||||||||||||||||||||
| Product family | ET 200SP motor starters | |||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | |||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||
| Metal Factor | None | |||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | |||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 20 Day/Days | |||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,570 Kg | |||||||||||||||||||||||||||||||||
| Packaging Dimension | 70,00 x 161,00 x 185,00 | |||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||
| EAN | 4047621012278 | |||||||||||||||||||||||||||||||||
| UPC | 804766246920 | |||||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | |||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||
| Product Group | 3724 | |||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 15.04.2016 | |||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Number of indicator lights (EF001965) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Type of electrical connection of main circuit (EF006819) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Rail mounting possible (EF003972) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Number of command positions (EF001372) | - | |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| With fuse (EF006693) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Type of motor starter (EF009598) | - | |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Degree of protection (NEMA) (EF011959) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation current Ie (EF001443) | 3 | A |
| Overload release current setting (EF002336) | ['0.9', '3'] | A |
| Release class (EF006668) | Other | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 1 | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 30.0 | mm |
| Height (EF000040) | 142.0 | mm |
| Depth (EF000049) | 150.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |
| Rated operation power at AC-3, 400 V (EF001364) | - | kW |










