View larger
3RK1308-0AE00-0CP0 SIEMENS Direct-on-line starter High Feature Incl. fan (3RW4928-8VB00) Electronic switchin..
3RK1308-0AE00-0CP0
13080
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
AS-Interface switchgear, SIMOCODE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Siemens 3RK1308-0AE00-0CP0 unit is an electronic direct-on-line starter complete with an integrated fan, built for modular motor control systems. Direct-on-line starters are standard industrial components used to connect electric motors directly to the power supply for straightforward, immediate starting in production lines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product category: Motor starter
- product designation: Direct-on-line starter
- product type designation: ET 200SP
- General technical data trip class: CLASS OFF / 5 / 10 adjustable
- equipment variant according to IEC 60947-4-2: 3
- product function: Direct-on-line starter
- ● on-site operation: Yes
- ● intrinsic device protection: Yes
- ● remote firmware update: Yes
- ● for power supply reverse polarity protection: Yes
- insulation voltage rated value: 500 V
- degree of pollution: 2
- overvoltage category: III
- surge voltage resistance rated value: 6 kV
- ● between main and auxiliary circuit: 500 V
- shock resistance: 6g / 11 ms
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1308-0AE00-0CP0 | ||||||||||||||||||||||||||||||
| Product Description | Direct-on-line starter High Feature; Incl. fan (3RW4928-8VB00); Electronic switching; Electronic overload protection up to 5.5 kW / 400 V; Adjustment range 4.0 .. 12 A; PROFIenergy; Option: 3DI/LC module | ||||||||||||||||||||||||||||||
| Product family | ET 200SP motor starters | ||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||
| Metal Factor | None | ||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||
| Standard lead time ex-works | 60 Day/Days | ||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,560 Kg | ||||||||||||||||||||||||||||||
| Packaging Dimension | 170,00 x 180,00 x 70,00 | ||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||
| EAN | 4047621031521 | ||||||||||||||||||||||||||||||
| UPC | 804766405693 | ||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | ||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||
| Product Group | 3724 | ||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 15.04.2016 | ||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Type of motor starter (EF009598) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Number of command positions (EF001372) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Rail mounting possible (EF003972) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Supporting protocol for CAN (EF003053) | - | |
| Type of electrical connection of main circuit (EF006819) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Number of indicator lights (EF001965) | - | |
| With fuse (EF006693) | - | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation current Ie (EF001443) | 12 | A |
| Overload release current setting (EF002336) | ['4', '12'] | A |
| Release class (EF006668) | Other | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 1 | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 30.0 | mm |
| Height (EF000040) | 142.0 | mm |
| Depth (EF000049) | 150.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |
| Rated operation power at AC-3, 400 V (EF001364) | - | kW |










