This Siemens 3RK1301-1EB00-0AA2 motor starter module for the ET 200S system provides standardized direct-on-line motor control within distributed I/O architectures. Distributed motor starters are widely used in modular plant engineering to streamline electrical installation and reduce control cabinet wiring.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Motor starters
- design of the product: direct starter
- product type designation: ET 200S
- General technical data trip class: CLASS 10
- product function on-site operation: Yes
- insulation voltage rated value: 500 V
- degree of pollution: 3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)
- surge voltage resistance rated value: 6 kV
- shock resistance: 5g / 11 ms
- vibration resistance: 2g
- operating frequency maximum: 750 1/h
- type of assignment: 1
- reference code according to IEC 81346-2: Q
- Substance Prohibitance (Date): 10/26/2016
- ● direct start: Yes
- ● reverse starting: No
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1301-1EB00-0AA2 | ||||||||||||||||||||||||||||||||||||
| Product Description | DS1-X for ET 200S Standard DOL starter expandable Setting range 2.8...4 A AC-3, 1.5 kW / 400 V Electromechanical starter for brake control module | ||||||||||||||||||||||||||||||||||||
| Product family | Standard motor starters | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | ||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | ||||||||||||||||||||||||||||||||||||
| Notes | Sucessor:The successor is the ET 200SP system with its compact motor starter modules. | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 50 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,883 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 198,00 x 286,00 x 112,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209512979 | ||||||||||||||||||||||||||||||||||||
| UPC | 040892691726 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 4962 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 26.10.2016 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Number of indicator lights (EF001965) | - | |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Rail mounting possible (EF003972) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Supporting protocol for CAN (EF003053) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Number of command positions (EF001372) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Supporting protocol for Modbus (EF003057) | - | |
| With fuse (EF006693) | - | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Type of motor starter (EF009598) | Direct online starter (DOL) | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['20.4', '28.8'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 1.5 | kW |
| Rated operation current Ie (EF001443) | - | A |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Overload release current setting (EF002336) | ['2.8', '4'] | A |
| Release class (EF006668) | CLASS 10 | |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 1 | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 45.0 | mm |
| Height (EF000040) | 265.0 | mm |
| Depth (EF000049) | 120.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |