View larger
3RK1301-1DB00-1AA2 SIEMENS RS1-X for ET 200S Standard reversing starter expandable Setting range 2.2....3.2 ..
3RK1301-1DB00-1AA2
13011
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
AS-Interface switchgear, SIMOCODE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens part 3RK1301-1DB00-1AA2 is a reversing starter engineered for deployment within modular distributed I/O systems. Motor starters of this classification safely manage rotational direction and operational protection for industrial electric motors in complex automated environments. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- product designation: Motor starters
- design of the product: reversing starter
- product type designation: ET 200S
- General technical data trip class: CLASS 10
- product function on-site operation: Yes
- insulation voltage rated value: 500 V
- degree of pollution: 3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)
- surge voltage resistance rated value: 6 kV
- shock resistance: 5g / 11 ms
- vibration resistance: 2g
- operating frequency maximum: 750 1/h
- type of assignment: 1
- reference code according to IEC 81346-2: Q
- Substance Prohibitance (Date): 10/26/2016
- ● direct start: No
- ● reverse starting: Yes
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1301-1DB00-1AA2 | ||||||||||||||||||||||||||||||||||||
| Product Description | RS1-X for ET 200S Standard reversing starter expandable Setting range 2.2....3.2 A AC-3, 1.1 kW / 400 V Electromechanical starter for brake control module | ||||||||||||||||||||||||||||||||||||
| Product family | Standard motor starters | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | ||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | ||||||||||||||||||||||||||||||||||||
| Notes | Sucessor:The successor is the ET 200SP system with its compact motor starter modules. | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 50 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,372 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 198,00 x 286,00 x 157,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209498778 | ||||||||||||||||||||||||||||||||||||
| UPC | 662643244717 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85365080 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 4962 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 26.10.2016 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Rail mounting possible (EF003972) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| With fuse (EF006693) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| External reset possible (EF003426) | - | |
| Number of command positions (EF001372) | - | |
| Number of indicator lights (EF001965) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| Type of motor starter (EF009598) | Reversing starter | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['20.4', '28.8'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 1.1 | kW |
| Rated operation current Ie (EF001443) | - | A |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Overload release current setting (EF002336) | ['2.2', '3.2'] | A |
| Release class (EF006668) | CLASS 10 | |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 1 | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 90.0 | mm |
| Height (EF000040) | 265.0 | mm |
| Depth (EF000049) | 120.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |