Engineered for modular automation architectures, this Siemens 3RK1301-1BB00-1AA2 motor starter enables efficient bi-directional control of industrial loads. Reversing starters are widely integrated into production lines, material handling equipment, and automated assembly cells where precise forward and backward motor operation is required. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- product designation: Motor starters
- design of the product: reversing starter
- product type designation: ET 200S
- General technical data trip class: CLASS 10
- product function on-site operation: Yes
- insulation voltage rated value: 500 V
- degree of pollution: 3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)
- surge voltage resistance rated value: 6 kV
- shock resistance: 5g / 11 ms
- vibration resistance: 2g
- operating frequency maximum: 750 1/h
- type of assignment: 2
- reference code according to IEC 81346-2: Q
- Substance Prohibitance (Date): 10/26/2016
- ● direct start: No
- ● reverse starting: Yes
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1301-1BB00-1AA2 | ||||||||||||||||||||||||||||||||||||
| Product Description | RS1-X for ET 200S Standard reversing starter expandable Setting range 1.4...2 A AC-3, 0.75 kW / 400 V Electromechanical starter for brake control module | ||||||||||||||||||||||||||||||||||||
| Product family | Standard motor starters | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | ||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | ||||||||||||||||||||||||||||||||||||
| Notes | Sucessor:The successor is the ET 200SP system with its compact motor starter modules. | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 50 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,320 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 198,00 x 286,00 x 157,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209498754 | ||||||||||||||||||||||||||||||||||||
| UPC | 662643248319 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 4962 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 26.10.2016 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Supporting protocol for SUCONET (EF003060) | - | |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| With fuse (EF006693) | - | |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Number of indicator lights (EF001965) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| External reset possible (EF003426) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Rail mounting possible (EF003972) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Number of command positions (EF001372) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Type of motor starter (EF009598) | Reversing starter | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['20.4', '28.8'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 0.75 | kW |
| Rated operation current Ie (EF001443) | - | A |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Overload release current setting (EF002336) | ['1.4', '2'] | A |
| Release class (EF006668) | CLASS 10 | |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 90.0 | mm |
| Height (EF000040) | 265.0 | mm |
| Depth (EF000049) | 120.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |