View larger
3RK1301-0HB00-1AA2 SIEMENS RS1-X for ET 200S Standard reversing starter expandable Setting range 0.55...0.8 ..
3RK1301-0HB00-1AA2
13010
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
AS-Interface switchgear, SIMOCODE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Siemens 3RK1301-0HB00-1AA2 RS1-X for ET 200S Standard reversing starter expandable Setting range 0.55...0.8 .. functions as a motor starter designed to safely control and reverse industrial electric motors within automated architectures. Motor starters provide reliable switching, overload protection, and operational sequencing for machinery in manufacturing facilities. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- product designation: Motor starters
- design of the product: reversing starter
- product type designation: ET 200S
- General technical data trip class: CLASS 10
- product function on-site operation: Yes
- insulation voltage rated value: 500 V
- degree of pollution: 3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)
- surge voltage resistance rated value: 6 kV
- shock resistance: 5g / 11 ms
- vibration resistance: 2g
- operating frequency maximum: 750 1/h
- type of assignment: 2
- reference code according to IEC 81346-2: Q
- Substance Prohibitance (Date): 10/26/2016
- ● direct start: No
- ● reverse starting: Yes
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1301-0HB00-1AA2 | ||||||||||||||||||||||||||||||||||||
| Product Description | RS1-X for ET 200S Standard reversing starter expandable Setting range 0.55...0.8 A, AC-3, 0.21 kW / 400 V Electromechanical starter for brake control module | ||||||||||||||||||||||||||||||||||||
| Product family | Standard motor starters | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | ||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | ||||||||||||||||||||||||||||||||||||
| Notes | Sucessor:The successor is the ET 200SP system with its compact motor starter modules. | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 50 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,340 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 198,00 x 286,00 x 157,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209498716 | ||||||||||||||||||||||||||||||||||||
| UPC | 662643249330 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85365080 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 4962 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 26.10.2016 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Supporting protocol for SERCOS (EF006657) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Number of indicator lights (EF001965) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| With fuse (EF006693) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Rail mounting possible (EF003972) | - | |
| Number of command positions (EF001372) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Temperature compensated overload protection (EF009604) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Type of motor starter (EF009598) | Reversing starter | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['20.4', '28.8'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 0.21 | kW |
| Rated operation current Ie (EF001443) | - | A |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Overload release current setting (EF002336) | ['0.55', '0.8'] | A |
| Release class (EF006668) | CLASS 10 | |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 90.0 | mm |
| Height (EF000040) | 265.0 | mm |
| Depth (EF000049) | 120.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |