View larger
3RK1301-0HB00-0AA2 SIEMENS DS1-X for ET 200S Standard DOL starter expandable Setting range 0.55...0.8 A, AC-..
3RK1301-0HB00-0AA2
13010
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
AS-Interface switchgear, SIMOCODE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Siemens 3RK1301-0HB00-0AA2 standard direct-on-line starter is designed for seamless integration within the ET 200S distributed I/O system. Modular motor starters are widely utilized in modern automation setups to manage and protect industrial drives while minimizing wiring complexity inside control enclosures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Motor starters
- design of the product: direct starter
- product type designation: ET 200S
- General technical data trip class: CLASS 10
- product function on-site operation: Yes
- insulation voltage rated value: 500 V
- degree of pollution: 3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)
- surge voltage resistance rated value: 6 kV
- shock resistance: 5g / 11 ms
- vibration resistance: 2g
- operating frequency maximum: 750 1/h
- type of assignment: 2
- reference code according to IEC 81346-2: Q
- Substance Prohibitance (Date): 10/26/2016
- ● direct start: Yes
- ● reverse starting: No
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1301-0HB00-0AA2 | ||||||||||||||||||||||||||||||||||||
| Product Description | DS1-X for ET 200S Standard DOL starter expandable Setting range 0.55...0.8 A, AC-3, 0.21 kW / 400 V Electromechanical starter for brake control module | ||||||||||||||||||||||||||||||||||||
| Product family | Standard motor starters | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | ||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | ||||||||||||||||||||||||||||||||||||
| Notes | Sucessor:The successor is the ET 200SP system with its compact motor starter modules. | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 50 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,900 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 198,00 x 286,00 x 112,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209512900 | ||||||||||||||||||||||||||||||||||||
| UPC | 662643248326 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 4962 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 26.10.2016 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Number of command positions (EF001372) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Number of indicator lights (EF001965) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Rail mounting possible (EF003972) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Degree of protection (NEMA) (EF011959) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Supporting protocol for TCP/IP (EF003050) | - | |
| With fuse (EF006693) | - | |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Type of motor starter (EF009598) | Direct online starter (DOL) | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['20.4', '28.8'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 0.21 | kW |
| Rated operation current Ie (EF001443) | - | A |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Overload release current setting (EF002336) | ['0.55', '0.8'] | A |
| Release class (EF006668) | CLASS 10 | |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 45.0 | mm |
| Height (EF000040) | 265.0 | mm |
| Depth (EF000049) | 120.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |






