Direct soft starter units like the Siemens 3RK1301-0BB20-0AB4 DSS1E-X combine efficient motor control with the advanced capabilities of the ET 200S High Feature platform. Such components ensure smooth ramp-up characteristics and reliable protection parameters for industrial automation tasks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Motor starters
- design of the product: direct starter
- product type designation: ET 200S
- General technical data trip class: CLASS 10 and 10A adjustable
- product function on-site operation: Yes
- insulation voltage rated value: 500 V
- degree of pollution: 3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)
- surge voltage resistance rated value: 6 kV
- shock resistance: 5g / 11 ms
- vibration resistance: 2g
- type of assignment: 1
- reference code according to IEC 81346-2: Q
- Substance Prohibitance (Date): 10/26/2016
- ● direct start: Yes
- ● reverse starting: No
- product component motor brake output: Yes
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1301-0BB20-0AB4 | ||||||||||||||||||||||||||||||||||||
| Product Description | DSS1E-X for ET200S High Feature direct soft starter Setting range 2.4...8 A Electronic switching Electronic protection AC-3, up to 3 kW / 400 V expandable for Brake control module 2DI module Motor starter ES Circuit breaker signaling parameterizable DPV 1-capable PROFIENERGY-capable to PN | ||||||||||||||||||||||||||||||||||||
| Product family | High Feature motor starters | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | ||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | ||||||||||||||||||||||||||||||||||||
| Notes | Sucessor:The successor is the ET 200SP system with its compact motor starter modules. | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,236 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 229,00 x 333,00 x 132,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209890299 | ||||||||||||||||||||||||||||||||||||
| UPC | 040892921830 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 4962 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 26.10.2016 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Rail mounting possible (EF003972) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Number of indicator lights (EF001965) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| With fuse (EF006693) | - | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Supporting protocol for Modbus (EF003057) | - | |
| Number of command positions (EF001372) | - | |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Type of motor starter (EF009598) | Direct online starter (DOL) | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['20.4', '28.8'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 3.0 | kW |
| Rated operation current Ie (EF001443) | - | A |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Overload release current setting (EF002336) | ['2.4', '8'] | A |
| Release class (EF006668) | Other | |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 1 | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 65.0 | mm |
| Height (EF000040) | 290.0 | mm |
| Depth (EF000049) | 150.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |