View larger
3RK1301-0BB13-1AA2 SIEMENS F-RS1E-X for ET 200S Failsafe reversing starter Setting range 2.4...8 A Mechanica..
3RK1301-0BB13-1AA2
13010
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
AS-Interface switchgear, SIMOCODE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for ET 200S modular architectures, the Siemens 3RK1301-0BB13-1AA2 SIEMENS F-RS1E-X for ET 200S Failsafe reversing starter Setting range 2.4...8 A Mechanica.. serves as a failsafe reversing motor starter. Safety-integrated motor starters allow secure directional control and emergency disconnection in automated safety-instrumented systems. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Motor starters
- design of the product: reversing starter
- product type designation: ET 200S
- General technical data trip class: CLASS 10 and 20 adjustable
- product function on-site operation: Yes
- insulation voltage rated value: 500 V
- degree of pollution: 3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)
- surge voltage resistance rated value: 6 kV
- shock resistance: 5g / 11 ms
- vibration resistance: 2g
- operating frequency maximum: 80 1/h
- type of assignment: 2
- reference code according to IEC 81346-2: Q
- Substance Prohibitance (Date): 10/26/2016
- ● direct start: No
- ● reverse starting: Yes
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1301-0BB13-1AA2 | |||||||||||||||||||||||||||||||||
| Product Description | F-RS1E-X for ET 200S Failsafe reversing starter Setting range 2.4...8 A Mechanical switching Electronic protection AC-3, up to 3 kW / 400 V expandable for brake control module for 2DI control module | |||||||||||||||||||||||||||||||||
| Product family | Ordering Data Overview | |||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | |||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | |||||||||||||||||||||||||||||||||
| Notes | Sucessor:The successor is the ET 200SP system with its compact motor starter modules. | |||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | |||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | |||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | |||||||||||||||||||||||||||||||||
| Net Weight (kg) | 2,520 Kg | |||||||||||||||||||||||||||||||||
| Packaging Dimension | 229,00 x 333,00 x 197,00 | |||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||
| EAN | 4011209548633 | |||||||||||||||||||||||||||||||||
| UPC | Not available | |||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||
| Product Group | 4962 | |||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 26.10.2016 | |||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Number of command positions (EF001372) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Rail mounting possible (EF003972) | - | |
| External reset possible (EF003426) | - | |
| Number of indicator lights (EF001965) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| With fuse (EF006693) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Type of motor starter (EF009598) | Reversing starter | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['21.6', '26.4'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 3.0 | kW |
| Rated operation current Ie (EF001443) | - | A |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Overload release current setting (EF002336) | ['2.4', '8'] | A |
| Release class (EF006668) | Other | |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 130.0 | mm |
| Height (EF000040) | 290.0 | mm |
| Depth (EF000049) | 150.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |