View larger
3RK1301-0BB10-0AB4 SIEMENS DS1E-X for ET200S High Feature DOL starter Setting range 2.4...8 A Mechanical swi..
3RK1301-0BB10-0AB4
13010
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
AS-Interface switchgear, SIMOCODE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Motor starters such as the Siemens 3RK1301-0BB10-0AB4 SIEMENS DS1E-X for ET200S High Feature DOL starter integrate seamlessly into distributed modular I/O systems to control and protect industrial drives. These units execute reliable switching tasks while communicating operational status back to the central control architecture.
Exact pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Motor starters
- design of the product: direct starter
- product type designation: ET 200S
- General technical data trip class: CLASS 5, 10, 15, 20
- product function on-site operation: Yes
- insulation voltage rated value: 500 V
- degree of pollution: 3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)
- surge voltage resistance rated value: 6 kV
- shock resistance: 5g / 11 ms
- vibration resistance: 2g
- type of assignment: 2
- reference code according to IEC 81346-2: Q
- Substance Prohibitance (Date): 10/26/2016
- ● direct start: Yes
- ● reverse starting: No
- product component motor brake output: Yes
More info
▲Technical data
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1301-0BB10-0AB4 | ||||||||||||||||||||||||||||||||||||
| Product Description | DS1E-X for ET200S High Feature DOL starter Setting range 2.4...8 A Mechanical switching Electronic protection AC-3, up to 3 kW / 400 V expandable for Brake control module 2DI module 2DI module Motor starter ES Circuit breaker signaling parameterizable DPV 1-capable PROFIENERGY-capable to PN | ||||||||||||||||||||||||||||||||||||
| Product family | High Feature motor starters | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | ||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 01.10.2020 | ||||||||||||||||||||||||||||||||||||
| Notes | Sucessor:The successor is the ET 200SP system with its compact motor starter modules. | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 10 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,550 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 229,00 x 333,00 x 132,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209890237 | ||||||||||||||||||||||||||||||||||||
| UPC | 040892921816 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 4962 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 26.10.2016 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Number of command positions (EF001372) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Rail mounting possible (EF003972) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Number of indicator lights (EF001965) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| External reset possible (EF003426) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| With fuse (EF006693) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Type of motor starter (EF009598) | Direct online starter (DOL) | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['20.4', '28.8'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 3.0 | kW |
| Rated operation current Ie (EF001443) | - | A |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Overload release current setting (EF002336) | ['2.4', '8'] | A |
| Release class (EF006668) | Other | |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 65.0 | mm |
| Height (EF000040) | 290.0 | mm |
| Depth (EF000049) | 150.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |






