An auxiliary contactor relay provides low-capacity electrical switching in control circuits, enabling automation systems to sequence operations, interlock safety functions, and route control signals. This Siemens component uses ring cable lug connections and is designed for direct current control applications.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Auxiliary contactor
- product type designation: 3RH2
- General technical data size of contactor: S00
- product extension auxiliary switch: Yes
- degree of pollution: 3
- surge voltage resistance rated value: 6 kV
- ● at DC: 10g / 5 ms, 5g / 10 ms
- ● at DC: 15g / 5 ms, 8g / 10 ms
- ● of contactor typical: 30 000 000
- ● of the contactor with added auxiliary switch block typical: 10 000 000
- reference code according to IEC 81346-2: K
- Substance Prohibitance (Date): 10/01/2009
- ● during operation: -25 ... +60 °C
- ● during storage: -55 ... +80 °C
- relative humidity minimum: 10 %
- ● at AC: 10 000 1/h
More info
▲Technical data
Additional data
| Product | ||||||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RH2140-4BG40 | |||||||||||||||||||||||||||||||||||||||
| Product Description | Contactor relay, 4 NO, 125 V DC, Size S00, ring cable lug connection | |||||||||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RH2 contactor relays, 4- and 8-pole | |||||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41A / 41A | |||||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||||||||
| Metal Factor | LBP----- | |||||||||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 60 Day/Days | |||||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,284 Kg | |||||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 50,00 x 61,50 x 77,50 | |||||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||||||||
| EAN | 4011209897298 | |||||||||||||||||||||||||||||||||||||||
| UPC | 662643907254 | |||||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||||||||
| Product Group | 5331 | |||||||||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2009 | |||||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |||||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000196 - Contactor relay
| Value | Unit | |
|---|---|---|
| Mounting method (EF000003) | - | |
| Manual operation possible (EF005881) | - | |
| Interface (EF000594) | - | |
| With LED indication (EF005950) | - | |
| Rated control supply voltage Us at DC (EF003980) | ['-', '125'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation current Ie, 400 V (EF001378) | 3 | A |
| Connection type auxiliary circuit (EF006820) | Other | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | 4 | |
| Number of auxiliary contacts as normally closed contact, delayed switching (EF007281) | - | |
| Number of auxiliary contacts as normally open contact, leading (EF007282) | - | |
| Number of auxiliary contacts as change-over contact (EF003531) | - | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |