View larger
3RF2320-3AA24 SIEMENS Solid-state contactor 1-phase 3RF2 AC 51 / 20 A / 40 °C 48-460 V / 110-230 V AC Ring c..
3RF2320-3AA24
23203
SIEMENS
1 Pcs.
Automation > Power contactor, AC switching
Contactors for switching motors
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The 3RF2320-3AA24 SIEMENS Solid-state contactor utilizes semiconductor technology to execute high-frequency, wear-free switching of electrical loads in automated thermal and motor processes. Unlike mechanical alternatives, these units provide silent, rapid operation for sensitive control environments.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: solid-state contactor
- design of the product: single-phase
- product type designation: 3RF23
- ● _1 of the accessories that can be ordered: 3RF2900-3PA88
- ● _4 of the accessories that can be ordered: 3RF2920-0GA36
- ● _1 of the accessories that can be ordered: terminal cover
- ● _4 of the accessories that can be ordered: load monitoring
- General technical data product function: zero-point switching
- insulation voltage rated value: 600 V
- degree of pollution: 3
- type of voltage of the control supply voltage: AC
- surge voltage resistance of main circuit rated value: 6 kV
- shock resistance according to IEC 60068-2-27: 15g / 11 ms
- vibration resistance according to IEC 60068-2-6: 2g
- reference code according to IEC 81346-2: Q
- Substance Prohibitance (Date): 05/28/2009
More info
▲Technical data
| Solid-state contactor 1-phase 3RF2 AC 51 / 20 A / 40 °C 48-460 V / 110-230 V AC Ring cable connection | ||||||||||||||||||||||||||
| product brand name | SIRIUS | |||||||||||||||||||||||||
| product designation | solid-state contactor | |||||||||||||||||||||||||
| design of the product | single-phase | |||||||||||||||||||||||||
| product type designation | 3RF23 | |||||||||||||||||||||||||
| manufacturer's article number | ||||||||||||||||||||||||||
| ● _1 of the accessories that can be ordered | 3RF2900-3PA88 | |||||||||||||||||||||||||
| ● _4 of the accessories that can be ordered | 3RF2920-0GA36 | |||||||||||||||||||||||||
| product designation | ||||||||||||||||||||||||||
| ● _1 of the accessories that can be ordered | terminal cover | |||||||||||||||||||||||||
| ● _4 of the accessories that can be ordered | load monitoring | |||||||||||||||||||||||||
| General technical data | ||||||||||||||||||||||||||
| product function | zero-point switching | |||||||||||||||||||||||||
| power loss [W] for rated value of the current without load current share typical | 3.5 W | |||||||||||||||||||||||||
| insulation voltage rated value | 600 V | |||||||||||||||||||||||||
| degree of pollution | 3 | |||||||||||||||||||||||||
| type of voltage of the control supply voltage | AC | |||||||||||||||||||||||||
| surge voltage resistance of main circuit rated value | 6 kV | |||||||||||||||||||||||||
| shock resistance according to IEC 60068-2-27 | 15g / 11 ms | |||||||||||||||||||||||||
| vibration resistance according to IEC 60068-2-6 | 2g | |||||||||||||||||||||||||
| reference code according to IEC 81346-2 | Q | |||||||||||||||||||||||||
| Substance Prohibitance (Date) | 05/28/2009 | |||||||||||||||||||||||||
| Main circuit | ||||||||||||||||||||||||||
| number of poles for main current circuit | 1 | |||||||||||||||||||||||||
| number of NO contacts for main contacts | 1 | |||||||||||||||||||||||||
| number of NC contacts for main contacts | 0 | |||||||||||||||||||||||||
| operating voltage at AC | ||||||||||||||||||||||||||
| ● at 50 Hz rated value | 48 ... 460 V | |||||||||||||||||||||||||
| ● at 60 Hz rated value | 48 ... 460 V | |||||||||||||||||||||||||
| operating frequency rated value | 50 ... 60 Hz | |||||||||||||||||||||||||
| operating range relative to the operating voltage at AC | ||||||||||||||||||||||||||
| ● at 50 Hz | 40 ... 506 V | |||||||||||||||||||||||||
| ● at 60 Hz | 40 ... 506 V | |||||||||||||||||||||||||
| operational current | ||||||||||||||||||||||||||
| ● at AC-51 rated value | 20 A | |||||||||||||||||||||||||
| ● at AC-51 according to IEC 60947-4-3 | 13.2 A | |||||||||||||||||||||||||
| ● according to UL 508 rated value | 17.6 A | |||||||||||||||||||||||||
| operational current minimum | 500 mA | |||||||||||||||||||||||||
| rate of voltage rise at the thyristor for main contacts maximum permissible | 1 000 V/µs | |||||||||||||||||||||||||
| blocking voltage at the thyristor for main contacts maximum permissible | 1 200 V | |||||||||||||||||||||||||
| reverse current of the thyristor | 10 mA | |||||||||||||||||||||||||
| derating temperature | 40 °C | |||||||||||||||||||||||||
| surge current resistance rated value | 600 A | |||||||||||||||||||||||||
| I2t value maximum | 1 800 A²·s | |||||||||||||||||||||||||
| Control circuit/ Control | ||||||||||||||||||||||||||
| type of voltage of the control supply voltage | AC | |||||||||||||||||||||||||
| control supply voltage 1 at AC | ||||||||||||||||||||||||||
| ● at 50 Hz | 110 ... 230 V | |||||||||||||||||||||||||
| ● at 60 Hz | 110 ... 230 V | |||||||||||||||||||||||||
| control supply voltage frequency | ||||||||||||||||||||||||||
| ● 1 rated value | 50 Hz | |||||||||||||||||||||||||
| ● 2 rated value | 60 Hz | |||||||||||||||||||||||||
| control supply voltage at AC | ||||||||||||||||||||||||||
| ● at 50 Hz full-scale value for signal<0> recognition | 40 V | |||||||||||||||||||||||||
| ● at 60 Hz full-scale value for signal<0> recognition | 40 V | |||||||||||||||||||||||||
| control supply voltage | ||||||||||||||||||||||||||
| ● at AC initial value for signal <1> detection | 90 V | |||||||||||||||||||||||||
| symmetrical line frequency tolerance | 5 Hz | |||||||||||||||||||||||||
| control current at minimum control supply voltage | ||||||||||||||||||||||||||
| ● at AC | 2 mA | |||||||||||||||||||||||||
| control current at AC rated value | 15 mA | |||||||||||||||||||||||||
| ON-delay time | 40 ms; additionally max. one half-wave | |||||||||||||||||||||||||
| OFF-delay time | 40 ms; additionally max. one half-wave | |||||||||||||||||||||||||
| Auxiliary circuit | ||||||||||||||||||||||||||
| number of NC contacts for auxiliary contacts | 0 | |||||||||||||||||||||||||
| number of NO contacts for auxiliary contacts | 0 | |||||||||||||||||||||||||
| number of CO contacts for auxiliary contacts | 0 | |||||||||||||||||||||||||
| Installation/ mounting/ dimensions | ||||||||||||||||||||||||||
| fastening method | screw fixing and snap-on mounting on standard mounting rail 35 mm according to IEC 60715 | |||||||||||||||||||||||||
| ● side-by-side mounting | Yes | |||||||||||||||||||||||||
| height | 95 mm | |||||||||||||||||||||||||
| width | 22.5 mm | |||||||||||||||||||||||||
| depth | 120 mm | |||||||||||||||||||||||||
| Connections/ Terminals | ||||||||||||||||||||||||||
| type of electrical connection | ||||||||||||||||||||||||||
| ● for main current circuit | Ring cable lug connection | |||||||||||||||||||||||||
| ● for auxiliary and control circuit | ring terminal lug connection | |||||||||||||||||||||||||
| type of connectable conductor cross-sections | ||||||||||||||||||||||||||
| ● for main contacts for JIS cable lug | JIS C 2805 R 2-5, 5,5-5, 8-5, 14-5 | |||||||||||||||||||||||||
| ● for DIN cable lug for main contacts | DIN 46234 -5-2,5, -5-6, -5-10, -5-16, -5-25 | |||||||||||||||||||||||||
| type of connectable conductor cross-sections | ||||||||||||||||||||||||||
| ● for auxiliary and control contacts | ||||||||||||||||||||||||||
| — solid | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²) | |||||||||||||||||||||||||
| — finely stranded with core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²) | |||||||||||||||||||||||||
| — finely stranded without core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²) | |||||||||||||||||||||||||
| ● at AWG cables for auxiliary and control contacts | 1x (AWG 20 ... 12) | |||||||||||||||||||||||||
| tightening torque | ||||||||||||||||||||||||||
| ● for main contacts with screw-type terminals | 2 ... 2.5 N·m | |||||||||||||||||||||||||
| ● for auxiliary and control contacts with screw-type terminals | 0.5 ... 0.6 N·m | |||||||||||||||||||||||||
| tightening torque [lbf·in] | ||||||||||||||||||||||||||
| ● for auxiliary and control contacts with screw-type terminals | 4.5 ... 5.3 lbf·in | |||||||||||||||||||||||||
| design of the thread of the connection screw | ||||||||||||||||||||||||||
| ● for main contacts | M5 | |||||||||||||||||||||||||
| ● of the auxiliary and control contacts | M3 | |||||||||||||||||||||||||
| stripped length of the cable | ||||||||||||||||||||||||||
| ● for main contacts | 10 mm | |||||||||||||||||||||||||
| ● for auxiliary and control contacts | 10 mm | |||||||||||||||||||||||||
| Safety related data | ||||||||||||||||||||||||||
| protection class IP on the front according to IEC 60529 | IP00; IP20 with cover | |||||||||||||||||||||||||
| touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front with cover | |||||||||||||||||||||||||
| Ambient conditions | ||||||||||||||||||||||||||
| installation altitude at height above sea level maximum | 1 000 m | |||||||||||||||||||||||||
| ambient temperature | ||||||||||||||||||||||||||
| ● during operation | -25 ... +60 °C | |||||||||||||||||||||||||
| ● during storage | -55 ... +80 °C | |||||||||||||||||||||||||
| Electromagnetic compatibility | ||||||||||||||||||||||||||
| conducted interference | ||||||||||||||||||||||||||
| ● due to burst according to IEC 61000-4-4 | 2 kV / 5 kHz behavior criterion 2 | |||||||||||||||||||||||||
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV behavior criterion 2 | |||||||||||||||||||||||||
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV behavior criterion 2 | |||||||||||||||||||||||||
| ● due to high-frequency radiation according to IEC 61000-4-6 | 140 dBuV in the frequency range 0.15 ... 80 MHz, behavior criterion 1 | |||||||||||||||||||||||||
| field-based interference according to IEC 61000-4-3 | 80 MHz ... 1 GHz 10 V/m, behavior criterion 1 | |||||||||||||||||||||||||
| electrostatic discharge according to IEC 61000-4-2 | 4 kV contact discharging / 8 kV air discharging, behavior criterion 2 | |||||||||||||||||||||||||
| conducted HF interference emissions according to CISPR11 | Class A for industrial environment | |||||||||||||||||||||||||
| field-bound HF interference emission according to CISPR11 | Class B for the domestic, business and commercial environments | |||||||||||||||||||||||||
| Short-circuit protection, design of the fuse link | ||||||||||||||||||||||||||
| manufacturer's article number | ||||||||||||||||||||||||||
| ● of gS fuse for semiconductor protection at NH design usable | 3NE1814-0 | |||||||||||||||||||||||||
| ● of full range R fuse link for semiconductor protection at cylindrical design usable | 5SE1325 | |||||||||||||||||||||||||
| ● of back-up R fuse link for semiconductor protection at NH design usable | 3NE8015-1 | |||||||||||||||||||||||||
| ● of back-up R fuse link for semiconductor protection at cylindrical design 10 x 38 mm usable | 3NC1032 | |||||||||||||||||||||||||
| ● of back-up R fuse link for semiconductor protection at cylindrical design 14 x 51 mm usable | 3NC1450 | |||||||||||||||||||||||||
| ● of back-up R fuse link for semiconductor protection at cylindrical design 22 x 58 mm usable | 3NC2263 | |||||||||||||||||||||||||
| manufacturer's article number of the gG fuse | ||||||||||||||||||||||||||
| ● at NH design usable | 3NA6807 | |||||||||||||||||||||||||
| ● at cylindrical design 10 x 38 mm usable | 3NW6005-1; These fuses have a smaller rated current than the semiconductor relays | |||||||||||||||||||||||||
| ● at cylindrical design 14 x 51 mm usable | 3NW6105-1; These fuses have a smaller rated current than the semiconductor relays | |||||||||||||||||||||||||
| ● at cylindrical design 22 x 58 mm usable | 3NW6205-1; These fuses have a smaller rated current than the semiconductor relays | |||||||||||||||||||||||||
| manufacturer's article number | ||||||||||||||||||||||||||
| ● of DIAZED fuse usable | 5SB2711 | |||||||||||||||||||||||||
| ● of NEOZED fuse usable | 5SE2320 | |||||||||||||||||||||||||
| Certificates/ approvals | ||||||||||||||||||||||||||
Downloads and manuals | ||||||||||||||||||||||||||
| ||||||||||||||||||||||||||
| Further information | ||||||||||||||||||||||||||
Information- and Downloadcenter (Catalogs, Brochures,…) | ||||||||||||||||||||||||||
Industry Mall (Online ordering system) | ||||||||||||||||||||||||||
Cax online generator | ||||||||||||||||||||||||||
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) | ||||||||||||||||||||||||||
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) | ||||||||||||||||||||||||||
| last modified: | 1/26/2022 | |||||||||||||||||||||||||
| Date 5/9/2022 | Subject to change without notice © Copyright Siemens 2022 | |||||||||||||||||||||||||
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RF2320-3AA24 | ||||||||||||||||||||||||||||||||||||
| Product Description | Solid-state contactor 1-phase 3RF2 AC 51 / 20 A / 40 °C 48-460 V / 110-230 V AC Ring cable connection | ||||||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RF2 solid-state relays and solid-state contactors | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41C / 41C | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | None | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 40 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,240 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 28,00 x 108,50 x 147,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209572775 | ||||||||||||||||||||||||||||||||||||
| UPC | 754554861739 | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 3725 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 28.05.2009 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000066 - Power contactor, AC switching
| Value | Unit | |
|---|---|---|
| Rated operation power NEMA (EF011960) | - | kW |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['110', '230'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['110', '230'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
| Voltage type for actuating (EF008242) | AC | |
| Rated operation current Ie at AC-1, 400 V (EF001393) | 20 | A |
| Rated operation current Ie at AC-3, 400 V (EF001392) | - | A |
| Rated operation current Ie at AC-4, 400 V (EF008495) | - | A |
| Modular version (EF001126) | true | |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 | |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 | |
| Type of electrical connection of main circuit (EF006819) | Other | |
| Number of normally closed contacts as main contact (EF001375) | 0 | |
| Number of main contacts as normally open contact (EF001374) | 1 | |
| Rated operation power at AC-4, 400 V (EF008496) | - | kW |
| Rated operation power at AC-3, 400 V (EF001364) | - | kW |