SIEMENS 3RA2325-8XD30-1DG4 3RA2325-8XD30-1DG4 SIEMENS reversing contactor assembly, AC-3e/AC-3, 17 A, 7.5 kW / 400 V, 3-pole, 125 V DC,.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

3RA2325-8XD30-1DG4 SIEMENS reversing contactor assembly, AC-3e/AC-3, 17 A, 7.5 kW / 400 V, 3-pole, 125 V DC,..

3RA2325-8XD30-1DG4

23258

SIEMENS

1 Pcs.

reversing contactor assembly, AC-3e/AC-3, 17 A, 7.5 kW / 400 V, 3-pole, 125 V DC, with plugged-in varistor, screw terminal, electrical and mechanical interlock, 2 x auxiliary switch plugged on, auxiliary contacts: 2 x 3 NO + 2 NC COMB. CONTACTORS P / INVERSION AC-3, 7.5KW / 400V, TAM. S0, DC 125V, WITH VARISTOR. Manufactured to order. Non-Cancelable Non-Returnable.

Automation > Combination of contactors
Contactors for switching motors

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

reversing contactor assembly, AC-3e/AC-3, 17 A, 7.5 kW / 400 V, 3-pole, 125 V DC, with plugged-in varistor, screw terminal, electrical and mechanical interlock, 2 x auxiliary switch plugged on, auxiliary contacts: 2 x 3 NO + 2 NC
product brand nameSIRIUS
product designationReversing contactor assembly
product type designation3RA23
manufacturer's article number
● 1 of the supplied contactor3RT2025-1BG40
● 2 of the supplied contactor3RT2025-1BG40
● of the supplied RH assembly kit3RA2923-2AA1
General technical data
size of contactorS0
product extension auxiliary switchYes
shock resistance at rectangular impulse
● at AC7,5g / 5 ms, 4,7g / 10 ms
● at DC10g / 5 ms, 7,5g / 10 ms
shock resistance with sine pulse
● at AC11,8g / 5 ms, 7,4g / 10 ms
● at DC15g / 5 ms, 10g / 10 ms
mechanical service life (operating cycles)
● of contactor typical10 000 000
● of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (Date)07/01/2006
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
● during operation-25 ... +60 °C
● during storage-55 ... +80 °C
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
operating voltage
● at AC-3 rated value maximum690 V
● at AC-3e rated value maximum690 V
operational current
● at AC-3
— at 400 V rated value17 A
— at 500 V rated value17 A
— at 690 V rated value13 A
● at AC-3e
— at 400 V rated value17 A
— at 500 V rated value17 A
— at 690 V rated value13 A
operating power
● at AC-3
— at 400 V rated value7.5 kW
— at 500 V rated value7.5 kW
— at 690 V rated value11 kW
● at AC-3e
— at 400 V rated value7.5 kW
— at 690 V rated value11 kW
● at AC-4 at 400 V rated value7.5 kW
operating frequency
● at AC-3 maximum1 000 1/h
● at AC-3e maximum1 000 1/h
Control circuit/ Control
type of voltage of the control supply voltageDC
control supply voltage 1
● at DC rated value125 V
design of the surge suppressorwith varistor
closing power of magnet coil at DC5.9 W
holding power of magnet coil at DC5.9 W
Auxiliary circuit
number of NO contacts for auxiliary contacts
● per direction of rotation1
● instantaneous contact2
contact reliability of auxiliary contacts< 1 error per 100 million operating cycles
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor
● at 480 V rated value14 A
● at 600 V rated value17 A
yielded mechanical performance [hp] for 3-phase AC motor
● at 220/230 V rated value5 hp
● at 460/480 V rated value10 hp
● at 575/600 V rated value15 hp
contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
design of the fuse link
● for short-circuit protection of the main circuit
— with type of coordination 1 requiredgG NH 3NA, DIAZED 5SB, NEOZED 5SE: 63 A
— with type of assignment 2 requiredgG NH 3NA, DIAZED 5SB, NEOZED 5SE: 25 A
● for short-circuit protection of the auxiliary switch requiredfuse gG: 10 A
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening methodscrew and snap-on mounting onto 35 mm DIN rail
height101 mm
width90 mm
depth107 mm
required spacing
● with side-by-side mounting
— forwards6 mm
— backwards0 mm
— upwards6 mm
— downwards6 mm
— at the side6 mm
● for grounded parts
— forwards6 mm
— backwards0 mm
— upwards6 mm
— at the side6 mm
— downwards6 mm
● for live parts
— forwards6 mm
— backwards0 mm
— upwards6 mm
— downwards6 mm
— at the side6 mm
Connections/ Terminals
type of electrical connection
● for main current circuitscrew-type terminals
● for auxiliary and control circuitscrew-type terminals
● at contactor for auxiliary contactsScrew-type terminals
● of magnet coilScrew-type terminals
type of connectable conductor cross-sections for main contacts
● solid2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
● solid or stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
● finely stranded with core end processing2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
type of connectable conductor cross-sections
● for auxiliary contacts
— solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
Safety related data
B10 value with high demand rate according to SN 319201 000 000
proportion of dangerous failures
● with low demand rate according to SN 3192040 %
● with high demand rate according to SN 3192075 %
failure rate [FIT] with low demand rate according to SN 31920100 FIT
T1 value for proof test interval or service life according to IEC 6150820 a
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Communication/ Protocol
product function bus communicationYes
protocol is supported AS-Interface protocolNo
product function control circuit interface with IO linkNo
Certificates/ approvals

Downloads and manuals

General Product ApprovalDeclaration of ConformityTest CertificatesMarine / Shipping

Confirmation

EAC

UK Declaration of Conformity

EC/EU-Declaration of Conformity

Special Test Certificate

ABS (American Bureau of Shipping)

Marine / Shippingother

BV / Bureau Veritas

DNV / Det Norske Veritas

LR (Lloyds Register)

RINA / Registro Italiano Navale

RMRS / Russian Maritime Register

Confirmation

Further information
Siemens has decided to exit the Russian market (see here).
Siemens is working on the renewal of the current EAC certificates.
Please contact your local Siemens office on the status of validity of the EAC certification if you intend to import or offer to supply these products to an EAC relevant market (other than the sanctioned EAEU member states Russia or Belarus).
Information on the packaging
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Tripping characteristics, I²t, Let-through current
Further characteristics (e.g. electrical endurance, switching frequency)
last modified:11/21/2022
Date
6/29/2023
Subject to change without notice
© Copyright Siemens 2023


Additional data

Product
Article Number (Market Facing Number)3RA2325-8XD30-1DG4
Product Descriptionreversing contactor assembly, AC-3e/AC-3, 17 A, 7.5 kW / 400 V, 3-pole, 125 V DC, with plugged-in varistor, screw terminal, electrical and mechanical interlock, 2 x auxiliary switch plugged on, auxiliary contacts: 2 x 3 NO + 2 NC
Product familyOrdering Data Overview
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group41B / 41B
Surcharge for Raw MaterialsNone
Metal FactorLCO-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-worksOn request
Net Weight (kg)1,410 Kg
Packaging Dimension123,00 x 175,00 x 114,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4047621046891
UPCNot available
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group5337
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.07.2006
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass1227-37-10-09
eClass627-37-10-09
eClass7.127-37-10-09
eClass827-37-10-09
eClass927-37-10-09
eClass9.127-37-10-09
ETIM7EC000010
ETIM8EC000010
IDEA44755
UNSPSC1539-12-15-29

ETIM data

ETIM: EC000010 - Combination of contactors

Value Unit
Rated operation current Ie at AC-3, 400 V (EF001392) -A
Rated control supply voltage Us at DC (EF003980) -V
Type of electrical connection of main circuit (EF006819) -
Degree of protection (IP) (EF005474) -
Function (EF000030) -
Rated control supply voltage Us at AC 60HZ (EF003979) -V
Voltage type for actuating (EF008242) -
Degree of protection (NEMA) (EF011959) -
Rated operation power at AC-3, 400 V (EF001364) -kW
Rated control supply voltage Us at AC 50HZ (EF003978) -V
Rated operation power NEMA (EF011960) -kW



Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.