View larger
3RA2317-8XB11-5BB4 SIEMENS reversing contactor assembly, AC-3e/AC-3, 12 A, 5.5 kW / 400 V, 3-pole, 24 V DC, ..
3RA2317-8XB11-5BB4
23178
SIEMENS
1 Pcs.
Automation > Combination of contactors
Contactors for switching motors
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Siemens reversing contactor assembly provides the essential switching architecture required to alternate motor rotation directions in automated industrial infrastructure. These standardized units integrate interlocking features to prevent simultaneous closure of opposing contactors. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Reversing contactor assembly
- product type designation: 3RA23
- ● 1 of the supplied contactor: 3RT2017-1BB42
- ● 2 of the supplied contactor: 3RT2017-1BB42
- ● of the supplied RH assembly kit: 3RA2913-2AA1
- General technical data size of contactor: S00
- product extension auxiliary switch: Yes
- ● at AC: 7,3g / 5 ms, 4,7g / 10 ms
- ● at DC: 7.3g / 5 ms, 4.7g / 10 ms
- ● at AC: 11,4g / 5 ms, 7,3g / 10 ms
- ● at DC: 11,4g / 5 ms, 7,3g / 10 ms
- ● of contactor typical: 10 000 000
- ● of the contactor with added auxiliary switch block typical: 10 000 000
- reference code according to IEC 81346-2: Q
- Substance Prohibitance (Date): 07/01/2006
- ● during operation: -25 ... +60 °C
More info
▲Technical data
| reversing contactor assembly, AC-3e/AC-3, 12 A, 5.5 kW / 400 V, 3-pole, 24 V DC, solder pin connection, mechanical interlock with main current path wiring, without wiring of coil control | ||||||||||||||||||||||||||||||||||||||
| product brand name | SIRIUS | |||||||||||||||||||||||||||||||||||||
| product designation | Reversing contactor assembly | |||||||||||||||||||||||||||||||||||||
| product type designation | 3RA23 | |||||||||||||||||||||||||||||||||||||
| manufacturer's article number | ||||||||||||||||||||||||||||||||||||||
| ● 1 of the supplied contactor | 3RT2017-1BB42 | |||||||||||||||||||||||||||||||||||||
| ● 2 of the supplied contactor | 3RT2017-1BB42 | |||||||||||||||||||||||||||||||||||||
| ● of the supplied RH assembly kit | 3RA2913-2AA1 | |||||||||||||||||||||||||||||||||||||
| General technical data | ||||||||||||||||||||||||||||||||||||||
| size of contactor | S00 | |||||||||||||||||||||||||||||||||||||
| product extension auxiliary switch | Yes | |||||||||||||||||||||||||||||||||||||
| shock resistance at rectangular impulse | ||||||||||||||||||||||||||||||||||||||
| ● at AC | 7,3g / 5 ms, 4,7g / 10 ms | |||||||||||||||||||||||||||||||||||||
| ● at DC | 7.3g / 5 ms, 4.7g / 10 ms | |||||||||||||||||||||||||||||||||||||
| shock resistance with sine pulse | ||||||||||||||||||||||||||||||||||||||
| ● at AC | 11,4g / 5 ms, 7,3g / 10 ms | |||||||||||||||||||||||||||||||||||||
| ● at DC | 11,4g / 5 ms, 7,3g / 10 ms | |||||||||||||||||||||||||||||||||||||
| mechanical service life (operating cycles) | ||||||||||||||||||||||||||||||||||||||
| ● of contactor typical | 10 000 000 | |||||||||||||||||||||||||||||||||||||
| ● of the contactor with added auxiliary switch block typical | 10 000 000 | |||||||||||||||||||||||||||||||||||||
| reference code according to IEC 81346-2 | Q | |||||||||||||||||||||||||||||||||||||
| Substance Prohibitance (Date) | 07/01/2006 | |||||||||||||||||||||||||||||||||||||
| Ambient conditions | ||||||||||||||||||||||||||||||||||||||
| installation altitude at height above sea level maximum | 2 000 m | |||||||||||||||||||||||||||||||||||||
| ambient temperature | ||||||||||||||||||||||||||||||||||||||
| ● during operation | -25 ... +60 °C | |||||||||||||||||||||||||||||||||||||
| ● during storage | -55 ... +80 °C | |||||||||||||||||||||||||||||||||||||
| Main circuit | ||||||||||||||||||||||||||||||||||||||
| number of poles for main current circuit | 3 | |||||||||||||||||||||||||||||||||||||
| number of NO contacts for main contacts | 3 | |||||||||||||||||||||||||||||||||||||
| number of NC contacts for main contacts | 0 | |||||||||||||||||||||||||||||||||||||
| operating voltage | ||||||||||||||||||||||||||||||||||||||
| ● at AC-3 rated value maximum | 690 V | |||||||||||||||||||||||||||||||||||||
| ● at AC-3e rated value maximum | 690 V | |||||||||||||||||||||||||||||||||||||
| operational current | ||||||||||||||||||||||||||||||||||||||
| ● at AC-3 | ||||||||||||||||||||||||||||||||||||||
| — at 400 V rated value | 12 A | |||||||||||||||||||||||||||||||||||||
| — at 500 V rated value | 9.2 A | |||||||||||||||||||||||||||||||||||||
| — at 690 V rated value | 6.7 A | |||||||||||||||||||||||||||||||||||||
| ● at AC-3e | ||||||||||||||||||||||||||||||||||||||
| — at 400 V rated value | 12 A | |||||||||||||||||||||||||||||||||||||
| — at 500 V rated value | 9.2 A | |||||||||||||||||||||||||||||||||||||
| — at 690 V rated value | 6.7 A | |||||||||||||||||||||||||||||||||||||
| operating power | ||||||||||||||||||||||||||||||||||||||
| ● at AC-3 | ||||||||||||||||||||||||||||||||||||||
| — at 400 V rated value | 5.5 kW | |||||||||||||||||||||||||||||||||||||
| — at 500 V rated value | 5.5 kW | |||||||||||||||||||||||||||||||||||||
| — at 690 V rated value | 5.5 kW | |||||||||||||||||||||||||||||||||||||
| ● at AC-3e | ||||||||||||||||||||||||||||||||||||||
| — at 400 V rated value | 5.5 kW | |||||||||||||||||||||||||||||||||||||
| — at 690 V rated value | 5.5 kW | |||||||||||||||||||||||||||||||||||||
| ● at AC-4 at 400 V rated value | 4 kW | |||||||||||||||||||||||||||||||||||||
| operating frequency | ||||||||||||||||||||||||||||||||||||||
| ● at AC-3 maximum | 750 1/h | |||||||||||||||||||||||||||||||||||||
| ● at AC-3e maximum | 750 1/h | |||||||||||||||||||||||||||||||||||||
| Control circuit/ Control | ||||||||||||||||||||||||||||||||||||||
| type of voltage of the control supply voltage | DC | |||||||||||||||||||||||||||||||||||||
| control supply voltage 1 | ||||||||||||||||||||||||||||||||||||||
| ● at DC rated value | 24 V | |||||||||||||||||||||||||||||||||||||
| closing power of magnet coil at DC | 4 W | |||||||||||||||||||||||||||||||||||||
| holding power of magnet coil at DC | 4 W | |||||||||||||||||||||||||||||||||||||
| Auxiliary circuit | ||||||||||||||||||||||||||||||||||||||
| number of NC contacts for auxiliary contacts | ||||||||||||||||||||||||||||||||||||||
| ● per direction of rotation | 0 | |||||||||||||||||||||||||||||||||||||
| ● instantaneous contact | 0 | |||||||||||||||||||||||||||||||||||||
| number of NO contacts for auxiliary contacts | ||||||||||||||||||||||||||||||||||||||
| ● per direction of rotation | 1 | |||||||||||||||||||||||||||||||||||||
| ● instantaneous contact | 2 | |||||||||||||||||||||||||||||||||||||
| contact reliability of auxiliary contacts | < 1 error per 100 million operating cycles | |||||||||||||||||||||||||||||||||||||
| UL/CSA ratings | ||||||||||||||||||||||||||||||||||||||
| full-load current (FLA) for 3-phase AC motor | ||||||||||||||||||||||||||||||||||||||
| ● at 480 V rated value | 11 A | |||||||||||||||||||||||||||||||||||||
| ● at 600 V rated value | 11 A | |||||||||||||||||||||||||||||||||||||
| yielded mechanical performance [hp] for 3-phase AC motor | ||||||||||||||||||||||||||||||||||||||
| ● at 200/208 V rated value | 1.5 hp | |||||||||||||||||||||||||||||||||||||
| ● at 220/230 V rated value | 3 hp | |||||||||||||||||||||||||||||||||||||
| ● at 460/480 V rated value | 7.5 hp | |||||||||||||||||||||||||||||||||||||
| ● at 575/600 V rated value | 10 hp | |||||||||||||||||||||||||||||||||||||
| contact rating of auxiliary contacts according to UL | A600 / Q600 | |||||||||||||||||||||||||||||||||||||
| Short-circuit protection | ||||||||||||||||||||||||||||||||||||||
| design of the fuse link | ||||||||||||||||||||||||||||||||||||||
| ● for short-circuit protection of the main circuit | ||||||||||||||||||||||||||||||||||||||
| — with type of coordination 1 required | gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 50 A | |||||||||||||||||||||||||||||||||||||
| — with type of assignment 2 required | gG NH 3NA, DIAZED 5SB, NEOZED 5SE: 25 A | |||||||||||||||||||||||||||||||||||||
| ● for short-circuit protection of the auxiliary switch required | fuse gG: 10 A | |||||||||||||||||||||||||||||||||||||
| Installation/ mounting/ dimensions | ||||||||||||||||||||||||||||||||||||||
| mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface | |||||||||||||||||||||||||||||||||||||
| fastening method | screw and snap-on mounting onto 35 mm DIN rail | |||||||||||||||||||||||||||||||||||||
| height | 68 mm | |||||||||||||||||||||||||||||||||||||
| width | 90 mm | |||||||||||||||||||||||||||||||||||||
| depth | 73 mm | |||||||||||||||||||||||||||||||||||||
| required spacing | ||||||||||||||||||||||||||||||||||||||
| ● with side-by-side mounting | ||||||||||||||||||||||||||||||||||||||
| — forwards | 6 mm | |||||||||||||||||||||||||||||||||||||
| — backwards | 0 mm | |||||||||||||||||||||||||||||||||||||
| — upwards | 6 mm | |||||||||||||||||||||||||||||||||||||
| — downwards | 6 mm | |||||||||||||||||||||||||||||||||||||
| — at the side | 6 mm | |||||||||||||||||||||||||||||||||||||
| ● for grounded parts | ||||||||||||||||||||||||||||||||||||||
| — forwards | 6 mm | |||||||||||||||||||||||||||||||||||||
| — backwards | 0 mm | |||||||||||||||||||||||||||||||||||||
| — upwards | 6 mm | |||||||||||||||||||||||||||||||||||||
| — at the side | 6 mm | |||||||||||||||||||||||||||||||||||||
| — downwards | 6 mm | |||||||||||||||||||||||||||||||||||||
| ● for live parts | ||||||||||||||||||||||||||||||||||||||
| — forwards | 6 mm | |||||||||||||||||||||||||||||||||||||
| — backwards | 0 mm | |||||||||||||||||||||||||||||||||||||
| — upwards | 6 mm | |||||||||||||||||||||||||||||||||||||
| — downwards | 6 mm | |||||||||||||||||||||||||||||||||||||
| — at the side | 6 mm | |||||||||||||||||||||||||||||||||||||
| Connections/ Terminals | ||||||||||||||||||||||||||||||||||||||
| type of electrical connection | ||||||||||||||||||||||||||||||||||||||
| ● for main current circuit | solder pin connectors | |||||||||||||||||||||||||||||||||||||
| ● for auxiliary and control circuit | solder pin connectors | |||||||||||||||||||||||||||||||||||||
| ● at contactor for auxiliary contacts | solder pin connection | |||||||||||||||||||||||||||||||||||||
| ● of magnet coil | solder pin connection | |||||||||||||||||||||||||||||||||||||
| Safety related data | ||||||||||||||||||||||||||||||||||||||
| B10 value with high demand rate according to SN 31920 | 1 000 000 | |||||||||||||||||||||||||||||||||||||
| proportion of dangerous failures | ||||||||||||||||||||||||||||||||||||||
| ● with low demand rate according to SN 31920 | 40 % | |||||||||||||||||||||||||||||||||||||
| ● with high demand rate according to SN 31920 | 75 % | |||||||||||||||||||||||||||||||||||||
| failure rate [FIT] with low demand rate according to SN 31920 | 100 FIT | |||||||||||||||||||||||||||||||||||||
| T1 value for proof test interval or service life according to IEC 61508 | 20 a | |||||||||||||||||||||||||||||||||||||
| protection class IP on the front according to IEC 60529 | IP20 | |||||||||||||||||||||||||||||||||||||
| touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front | |||||||||||||||||||||||||||||||||||||
| Communication/ Protocol | ||||||||||||||||||||||||||||||||||||||
| product function bus communication | Yes | |||||||||||||||||||||||||||||||||||||
| protocol is supported AS-Interface protocol | No | |||||||||||||||||||||||||||||||||||||
| product function control circuit interface with IO link | No | |||||||||||||||||||||||||||||||||||||
| Certificates/ approvals | ||||||||||||||||||||||||||||||||||||||
Downloads and manuals | ||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||
| Further information | ||||||||||||||||||||||||||||||||||||||
Siemens has decided to exit the Russian market (see here). | ||||||||||||||||||||||||||||||||||||||
Siemens is working on the renewal of the current EAC certificates. Please contact your local Siemens office on the status of validity of the EAC certification if you intend to import or offer to supply these products to an EAC relevant market (other than the sanctioned EAEU member states Russia or Belarus). | ||||||||||||||||||||||||||||||||||||||
Information on the packaging | ||||||||||||||||||||||||||||||||||||||
Information- and Downloadcenter (Catalogs, Brochures,…) | ||||||||||||||||||||||||||||||||||||||
Industry Mall (Online ordering system) | ||||||||||||||||||||||||||||||||||||||
Cax online generator | ||||||||||||||||||||||||||||||||||||||
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) | ||||||||||||||||||||||||||||||||||||||
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) | ||||||||||||||||||||||||||||||||||||||
Characteristic: Tripping characteristics, I²t, Let-through current | ||||||||||||||||||||||||||||||||||||||
Further characteristics (e.g. electrical endurance, switching frequency) | ||||||||||||||||||||||||||||||||||||||
| last modified: | 11/21/2022 | |||||||||||||||||||||||||||||||||||||
| Date 6/29/2023 | Subject to change without notice © Copyright Siemens 2023 | |||||||||||||||||||||||||||||||||||||
Additional data
| Product | ||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RA2317-8XB11-5BB4 | |||||||||||||||||||||||||||||||||
| Product Description | reversing contactor assembly, AC-3e/AC-3, 12 A, 5.5 kW / 400 V, 3-pole, 24 V DC, solder pin connection, mechanical interlock with main current path wiring, without wiring of coil control | |||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RA23 reversing contactor assemblies, up to 55 kW | |||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41B / 41B | |||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||
| Metal Factor | LCO----- | |||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 30 Day/Days | |||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,660 Kg | |||||||||||||||||||||||||||||||||
| Packaging Dimension | 77,00 x 93,00 x 130,00 | |||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | |||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||
| EAN | 4011209920170 | |||||||||||||||||||||||||||||||||
| UPC | 887621011567 | |||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | |||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | |||||||||||||||||||||||||||||||||
| Product Group | 5337 | |||||||||||||||||||||||||||||||||
| Group Code | R711 | |||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | |||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC000010 - Combination of contactors
| Value | Unit | |
|---|---|---|
| Degree of protection (NEMA) (EF011959) | - | |
| Function (EF000030) | Reversing contactor | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '-'] | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '-'] | V |
| Rated control supply voltage Us at DC (EF003980) | ['-', '24'] | V |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation current Ie at AC-3, 400 V (EF001392) | 12 | A |
| Rated operation power at AC-3, 400 V (EF001364) | 5.5 | kW |
| Rated operation power NEMA (EF011960) | 5.516240625 | kW |
| Type of electrical connection of main circuit (EF006819) | Other | |
| Degree of protection (IP) (EF005474) | Other |