View larger
3RA2210-0JS15-2BB4 SIEMENS Load feeder fuseless, Reversing duty 400 V AC, Size S00 0.70...1.00 A 24 V DC Spr..
3RA2210-0JS15-2BB4
22100
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
Contactors for switching motors
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens part number 3RA2210-0JS15-2BB4 is a fuseless load feeder built for reversing motor duties in industrial power distribution panels. Load feeders of this variety combine circuit breakers and contactors into unified assemblies to safely start, switch, and protect downstream electrical motors.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Article Number (Market Facing Number): 3RA2210-0JS15-2BB4
- Product family: SIRIUS 3RA2 load feeders
- Product Lifecycle (PLM): PM300:Active Product
- Metal Factor: LCO-----
- Delivery information Export Control Regulations: AL : N / ECCN : EAR99
- Standard lead time ex-works: On request
- Net Weight (kg): 1,930 Kg
- Packaging Dimension: 246,00 x 326,00 x 222,00
- Package size unit of measure: MM
- Quantity Unit: 1 Piece
- Packaging Quantity: 1
- Additional Product Information EAN: 4011209937529
- UPC: Not available
- Commodity Code: 85364900
- LKZ_FDB/ CatalogID: CC-IC10
- Product Group: 5348
More info
▲Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RA2210-0JS15-2BB4 | ||||||||||||||||||||||||||||||||||||
| Product Description | Load feeder fuseless, Reversing duty 400 V AC, Size S00 0.70...1.00 A 24 V DC Spring-type terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NC (contactor) Adapter length 200 mm | ||||||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RA2 load feeders | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41D / 41D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LCO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : EAR99 | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | On request | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,930 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 246,00 x 326,00 x 222,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209937529 | ||||||||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5348 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2009 | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Supporting protocol for LON (EF003017) | - | |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for ASI (EF003051) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Rail mounting possible (EF003972) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Number of command positions (EF001372) | - | |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Type of motor starter (EF009598) | Other | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
| Voltage type for actuating (EF008242) | DC / DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 0.25 | kW |
| Rated operation current Ie (EF001443) | 0.85 | A |
| Rated operation current at AC-3, 400 V (EF009602) | 0.85 | A |
| Overload release current setting (EF002336) | ['0.7', '1'] | A |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Release class (EF006668) | CLASS 10 | |
| Type of electrical connection of main circuit (EF006819) | Spring clamp connection | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
| Number of indicator lights (EF001965) | 0 | |
| With fuse (EF006693) | false | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Width (EF000008) | 90.0 | mm |
| Height (EF000040) | 212.0 | mm |
| Depth (EF000049) | 155.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |