View larger
3RA2120-4BD27-0FB4 SIEMENS Load feeder fuseless, Direct-on-line starting 400 V AC, Size S0 13...20 A 24 V DC..
3RA2120-4BD27-0FB4
21204
SIEMENS
1 Pcs.
Automation > Motor starter/Motor starter combination
Contactors for switching motors
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens 3RA2120-4BD27-0FB4 is a fuseless direct-on-line load feeder configured for installation on busbar systems within electrical control cabinets. Load feeders combine circuit breakers and contactors to protect and switch motor circuits efficiently.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- product designation: Direct (on-line) starter
- design of the product: for 60 mm busbars
- product type designation: 3RA21
- ● of the supplied contactor: 3RT2027-1FB40
- ● of the supplied circuit-breakers: 3RV2021-4BA10
- ● of the supplied busbar adapter: 8US1251-5NT10
- ● of the supplied link module: 3RA2921-1BA00
- General technical data size of the circuit-breaker: S0
- size of load feeder: S0
- surge voltage resistance rated value: 6 kV
- shock resistance according to IEC 60068-2-27: 6g / 11 ms
- type of assignment: 2
- type of protection according to ATEX directive 2014/34/EU: Ex II (2) GD
- ● during operation: -20 ... +60 °C
- ● during storage: -50 ... +80 °C
- ● during transport: -50 ... +80 °C
More info
▲Technical data
| Load feeder fuseless, Direct-on-line starting 400 V AC, Size S0 13...20 A 24 V DC screw terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NO+1 NC (contactor) with diode combination plugged in at the front | ||||||||||||||||||||||||||||||||||||||||||||||||||
| product brand name | SIRIUS | |||||||||||||||||||||||||||||||||||||||||||||||||
| product designation | Direct (on-line) starter | |||||||||||||||||||||||||||||||||||||||||||||||||
| design of the product | for 60 mm busbars | |||||||||||||||||||||||||||||||||||||||||||||||||
| product type designation | 3RA21 | |||||||||||||||||||||||||||||||||||||||||||||||||
| manufacturer's article number | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ● of the supplied contactor | 3RT2027-1FB40 | |||||||||||||||||||||||||||||||||||||||||||||||||
| ● of the supplied circuit-breakers | 3RV2021-4BA10 | |||||||||||||||||||||||||||||||||||||||||||||||||
| ● of the supplied busbar adapter | 8US1251-5NT10 | |||||||||||||||||||||||||||||||||||||||||||||||||
| ● of the supplied link module | 3RA2921-1BA00 | |||||||||||||||||||||||||||||||||||||||||||||||||
| General technical data | ||||||||||||||||||||||||||||||||||||||||||||||||||
| size of the circuit-breaker | S0 | |||||||||||||||||||||||||||||||||||||||||||||||||
| size of load feeder | S0 | |||||||||||||||||||||||||||||||||||||||||||||||||
| insulation voltage with degree of pollution 3 at AC rated value | 690 V | |||||||||||||||||||||||||||||||||||||||||||||||||
| surge voltage resistance rated value | 6 kV | |||||||||||||||||||||||||||||||||||||||||||||||||
| degree of protection NEMA rating | other | |||||||||||||||||||||||||||||||||||||||||||||||||
| shock resistance according to IEC 60068-2-27 | 6g / 11 ms | |||||||||||||||||||||||||||||||||||||||||||||||||
| mechanical service life (switching cycles) of contactor typical | 10 000 000 | |||||||||||||||||||||||||||||||||||||||||||||||||
| type of assignment | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||
| type of protection according to ATEX directive 2014/34/EU | Ex II (2) GD | |||||||||||||||||||||||||||||||||||||||||||||||||
| certificate of suitability according to ATEX directive 2014/34/EU | DMT 02 ATEX F 001 | |||||||||||||||||||||||||||||||||||||||||||||||||
| Ambient conditions | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ambient temperature | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ● during operation | -20 ... +60 °C | |||||||||||||||||||||||||||||||||||||||||||||||||
| ● during storage | -50 ... +80 °C | |||||||||||||||||||||||||||||||||||||||||||||||||
| ● during transport | -50 ... +80 °C | |||||||||||||||||||||||||||||||||||||||||||||||||
| temperature compensation | -20 ... +60 °C | |||||||||||||||||||||||||||||||||||||||||||||||||
| relative humidity during operation | 10 ... 95 % | |||||||||||||||||||||||||||||||||||||||||||||||||
| Main circuit | ||||||||||||||||||||||||||||||||||||||||||||||||||
| number of poles for main current circuit | 3 | |||||||||||||||||||||||||||||||||||||||||||||||||
| design of the switching contact | electromechanical | |||||||||||||||||||||||||||||||||||||||||||||||||
| adjustable current response value current of the current-dependent overload release | 13 ... 20 A | |||||||||||||||||||||||||||||||||||||||||||||||||
| operating voltage | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ● rated value | 690 V | |||||||||||||||||||||||||||||||||||||||||||||||||
| ● at AC-3 rated value maximum | 690 V | |||||||||||||||||||||||||||||||||||||||||||||||||
| operating frequency rated value | 50 ... 60 Hz | |||||||||||||||||||||||||||||||||||||||||||||||||
| operational current at AC-3 at 400 V rated value | 15.5 A | |||||||||||||||||||||||||||||||||||||||||||||||||
| operating power at AC-3 | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ● at 400 V rated value | 7 500 W | |||||||||||||||||||||||||||||||||||||||||||||||||
| Control circuit/ Control | ||||||||||||||||||||||||||||||||||||||||||||||||||
| type of voltage of the control supply voltage | DC | |||||||||||||||||||||||||||||||||||||||||||||||||
| control supply voltage at DC | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ● rated value | 24 V | |||||||||||||||||||||||||||||||||||||||||||||||||
| ● rated value | 24 ... 24 V | |||||||||||||||||||||||||||||||||||||||||||||||||
| holding power of magnet coil at DC | 5.9 W | |||||||||||||||||||||||||||||||||||||||||||||||||
| Auxiliary circuit | ||||||||||||||||||||||||||||||||||||||||||||||||||
| product extension auxiliary switch | Yes | |||||||||||||||||||||||||||||||||||||||||||||||||
| Protective and monitoring functions | ||||||||||||||||||||||||||||||||||||||||||||||||||
| trip class | CLASS 10 | |||||||||||||||||||||||||||||||||||||||||||||||||
| design of the overload release | thermal (bimetallic) | |||||||||||||||||||||||||||||||||||||||||||||||||
| Short-circuit protection | ||||||||||||||||||||||||||||||||||||||||||||||||||
| product function short circuit protection | Yes | |||||||||||||||||||||||||||||||||||||||||||||||||
| design of the short-circuit trip | magnetic | |||||||||||||||||||||||||||||||||||||||||||||||||
| conditional short-circuit current (Iq) | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ● at 400 V according to IEC 60947-4-1 rated value | 150 000 A | |||||||||||||||||||||||||||||||||||||||||||||||||
| Installation/ mounting/ dimensions | ||||||||||||||||||||||||||||||||||||||||||||||||||
| mounting position | vertical | |||||||||||||||||||||||||||||||||||||||||||||||||
| fastening method | for snapping onto 60 mm busbar systems | |||||||||||||||||||||||||||||||||||||||||||||||||
| height | 260 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
| width | 45 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
| depth | 165 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
| required spacing | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ● for grounded parts | ||||||||||||||||||||||||||||||||||||||||||||||||||
| — forwards | 20 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
| — backwards | 0 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
| — upwards | 50 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
| — at the side | 20 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
| — downwards | 10 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
| ● for live parts | ||||||||||||||||||||||||||||||||||||||||||||||||||
| — forwards | 20 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
| — backwards | 0 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
| — upwards | 50 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
| — downwards | 10 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
| — at the side | 20 mm | |||||||||||||||||||||||||||||||||||||||||||||||||
| Connections/ Terminals | ||||||||||||||||||||||||||||||||||||||||||||||||||
| type of electrical connection | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ● for main current circuit | screw-type terminals | |||||||||||||||||||||||||||||||||||||||||||||||||
| ● for auxiliary and control circuit | screw-type terminals | |||||||||||||||||||||||||||||||||||||||||||||||||
| Safety related data | ||||||||||||||||||||||||||||||||||||||||||||||||||
| B10 value with high demand rate according to SN 31920 | 1 000 000 | |||||||||||||||||||||||||||||||||||||||||||||||||
| proportion of dangerous failures | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ● with high demand rate according to SN 31920 | 73 % | |||||||||||||||||||||||||||||||||||||||||||||||||
| touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front | |||||||||||||||||||||||||||||||||||||||||||||||||
| Communication/ Protocol | ||||||||||||||||||||||||||||||||||||||||||||||||||
| protocol is supported | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ● PROFINET IO protocol | No | |||||||||||||||||||||||||||||||||||||||||||||||||
| ● PROFIsafe protocol | No | |||||||||||||||||||||||||||||||||||||||||||||||||
| protocol is supported AS-Interface protocol | No | |||||||||||||||||||||||||||||||||||||||||||||||||
| Certificates/ approvals | ||||||||||||||||||||||||||||||||||||||||||||||||||
Downloads and manuals | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||
| Further information | ||||||||||||||||||||||||||||||||||||||||||||||||||
Information- and Downloadcenter (Catalogs, Brochures,…) | ||||||||||||||||||||||||||||||||||||||||||||||||||
Industry Mall (Online ordering system) | ||||||||||||||||||||||||||||||||||||||||||||||||||
Cax online generator | ||||||||||||||||||||||||||||||||||||||||||||||||||
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) | ||||||||||||||||||||||||||||||||||||||||||||||||||
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) | ||||||||||||||||||||||||||||||||||||||||||||||||||
Characteristic: Tripping characteristics, I²t, Let-through current | ||||||||||||||||||||||||||||||||||||||||||||||||||
Further characteristics (e.g. electrical endurance, switching frequency) | ||||||||||||||||||||||||||||||||||||||||||||||||||
| last modified: | 2/16/2022 | |||||||||||||||||||||||||||||||||||||||||||||||||
| Date 5/5/2022 | Subject to change without notice © Copyright Siemens 2022 | |||||||||||||||||||||||||||||||||||||||||||||||||
Additional data
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RA2120-4BD27-0FB4 | ||||||||||||||||||||||||||||||||||||
| Product Description | Load feeder fuseless, Direct-on-line starting 400 V AC, Size S0 13...20 A 24 V DC screw terminal for 60 mm busbar systems (also fulfills type of coordination 1) Type of coordination 2, Iq = 150 kA 1 NO+1 NC (contactor) with diode combination plugged in at the front | ||||||||||||||||||||||||||||||||||||
| Product family | SIRIUS 3RA2 load feeders | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 41D / 41D | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LCO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 200 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,451 Kg | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 221,00 x 306,00 x 87,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209933897 | ||||||||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85364900 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5348 | ||||||||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | not available | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||
ETIM data
ETIM: EC001037 - Motor starter/Motor starter combination
| Value | Unit | |
|---|---|---|
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Number of command positions (EF001372) | - | |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for ASI (EF003051) | - | |
| Supporting protocol for Modbus (EF003057) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Rail mounting possible (EF003972) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| External reset possible (EF003426) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Degree of protection (NEMA) (EF011959) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Type of motor starter (EF009598) | Other | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
| Voltage type for actuating (EF008242) | DC / DC | |
| Rated operation power at AC-3, 400 V (EF001364) | 7.5 | kW |
| Rated operation current Ie (EF001443) | 15.5 | A |
| Rated operation current at AC-3, 400 V (EF009602) | 15.5 | A |
| Overload release current setting (EF002336) | ['13', '20'] | A |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Release class (EF006668) | CLASS 10 | |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
| Number of indicator lights (EF001965) | 0 | |
| With fuse (EF006693) | false | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Width (EF000008) | 45.0 | mm |
| Height (EF000040) | 260.0 | mm |
| Depth (EF000049) | 165.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |











