View larger
3RA1130-4FB35-0AF0
11304
SIEMENS
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Value | Unit | |
|---|---|---|
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Rail mounting possible (EF003972) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| Release class (EF006668) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Supporting protocol for Modbus (EF003057) | - | |
| Number of command positions (EF001372) | - | |
| Suitable for emergency stop (EF001433) | - | |
| External reset possible (EF003426) | - | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Type of motor starter (EF009598) | Direct online starter (DOL) | |
| With short-circuit release (EF006691) | true | |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] | V |
| Voltage type for actuating (EF008242) | AC / #NO_DATA# | |
| Rated operation power at AC-3, 400 V (EF001364) | 18.5 | kW |
| Rated operation current Ie (EF001443) | 35 | A |
| Rated operation current at AC-3, 400 V (EF009602) | 35 | A |
| Overload release current setting (EF002336) | ['28', '40'] | A |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 | |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 | |
| Type of electrical connection of main circuit (EF006819) | Screw connection | |
| With transformer (EF000278) | false | |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 | |
| Number of indicator lights (EF001965) | 0 | |
| With fuse (EF006693) | false | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Supporting protocol for ASI (EF003051) | false | |
| Width (EF000008) | 55.0 | mm |
| Height (EF000040) | 295.0 | mm |
| Depth (EF000049) | 173.0 | mm |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |
| Load feeder fuseless direct-on-line starting, 400 V AC 28...40 A, 110 V AC 50 Hz Size S2 Screw terminal on adapter Screw and snap-on mounting Type of coordination 2, Iq = 50 kA (also fulfills type of coordination 1) !!! Phased-out product !!! Successor is SIRIUS 3RA2 | ||||||||||||||||||||||||||
| product brand name | SIRIUS | |||||||||||||||||||||||||
| Product designation | non-fused load feeder | |||||||||||||||||||||||||
| Design of the product | direct starter | |||||||||||||||||||||||||
| Manufacturer's article number | ||||||||||||||||||||||||||
| ● of the supplied contactor | 3RT1035-1AF00 | |||||||||||||||||||||||||
| ● of the supplied circuit-breakers | 3RV1031-4FA10 | |||||||||||||||||||||||||
| ● of the supplied link module | 3RA1931-1AA00 | |||||||||||||||||||||||||
| ● of the supplied standard mounting rail adapter | 3RA1932-1AA00 | |||||||||||||||||||||||||
| General technical data | ||||||||||||||||||||||||||
| Size of load feeder | S2 | |||||||||||||||||||||||||
| Product extension | ||||||||||||||||||||||||||
| ● Auxiliary switch | Yes | |||||||||||||||||||||||||
| ● Insulation voltage rated value | 690 V | |||||||||||||||||||||||||
| Degree of pollution | 3 | |||||||||||||||||||||||||
| Surge voltage resistance rated value | 6 kV | |||||||||||||||||||||||||
| ● protection class IP on the front | IP20 | |||||||||||||||||||||||||
| Shock resistance | 8g | |||||||||||||||||||||||||
| Mechanical service life (switching cycles) | ||||||||||||||||||||||||||
| ● of contactor typical | 10 000 000 | |||||||||||||||||||||||||
| Type of assignment | 2 | |||||||||||||||||||||||||
| ● certificate of suitability | UL / CSA / CCC / GL / LRS / BV / DNV / PRS | |||||||||||||||||||||||||
| Reference code acc. to DIN EN 81346-2 | Q | |||||||||||||||||||||||||
| Ambient conditions | ||||||||||||||||||||||||||
| Installation altitude at height above sea level | ||||||||||||||||||||||||||
| ● maximum | 2 000 m | |||||||||||||||||||||||||
| Ambient temperature | ||||||||||||||||||||||||||
| ● during operation | -20 ... +70 °C | |||||||||||||||||||||||||
| ● during storage | -55 ... +80 °C | |||||||||||||||||||||||||
| Main circuit | ||||||||||||||||||||||||||
| Number of poles for main current circuit | 3 | |||||||||||||||||||||||||
| design of the switching contact | electromechanical | |||||||||||||||||||||||||
| adjustable pick-up value current of the current-dependent overload release | 28 ... 40 A | |||||||||||||||||||||||||
| Type of the motor protection | bimetal | |||||||||||||||||||||||||
| Operating voltage | ||||||||||||||||||||||||||
| ● at AC-3 rated value maximum | 400 V | |||||||||||||||||||||||||
| Operating current | ||||||||||||||||||||||||||
| ● at AC-3 | ||||||||||||||||||||||||||
| — at 400 V rated value | 35 A | |||||||||||||||||||||||||
| Operating power | ||||||||||||||||||||||||||
| ● at AC-3 | ||||||||||||||||||||||||||
| — at 400 V rated value | 18.5 kW | |||||||||||||||||||||||||
| No-load switching frequency | 15 1/s | |||||||||||||||||||||||||
| Control circuit/ Control | ||||||||||||||||||||||||||
| Type of voltage of the control supply voltage | AC | |||||||||||||||||||||||||
| Control supply voltage 1 at AC | ||||||||||||||||||||||||||
| ● at 50 Hz rated value | 110 V | |||||||||||||||||||||||||
| control supply voltage frequency | ||||||||||||||||||||||||||
| ● 1 rated value | 50 Hz | |||||||||||||||||||||||||
| Auxiliary circuit | ||||||||||||||||||||||||||
| Number of NC contacts for auxiliary contacts | 0 | |||||||||||||||||||||||||
| Number of NO contacts for auxiliary contacts | 0 | |||||||||||||||||||||||||
| Number of CO contacts | ||||||||||||||||||||||||||
| ● for auxiliary contacts | 0 | |||||||||||||||||||||||||
| Protective and monitoring functions | ||||||||||||||||||||||||||
| Maximum short-circuit current breaking capacity (Icu) | ||||||||||||||||||||||||||
| ● at 400 V rated value | 50 kA | |||||||||||||||||||||||||
| Short-circuit protection | ||||||||||||||||||||||||||
| product function short circuit protection | Yes | |||||||||||||||||||||||||
| Design of short-circuit protection | circuit-breakers | |||||||||||||||||||||||||
| Installation/ mounting/ dimensions | ||||||||||||||||||||||||||
| ● mounting position | with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back | |||||||||||||||||||||||||
| Mounting type | snap-on fastening on 35 mm standard rail | |||||||||||||||||||||||||
| Height | 295 mm | |||||||||||||||||||||||||
| Width | 55 mm | |||||||||||||||||||||||||
| Depth | 173 mm | |||||||||||||||||||||||||
| Required spacing | ||||||||||||||||||||||||||
| ● with side-by-side mounting | ||||||||||||||||||||||||||
| — at the side | 0 mm | |||||||||||||||||||||||||
| ● for grounded parts | ||||||||||||||||||||||||||
| — forwards | 10 mm | |||||||||||||||||||||||||
| — Backwards | 0 mm | |||||||||||||||||||||||||
| — upwards | 50 mm | |||||||||||||||||||||||||
| — at the side | 10 mm | |||||||||||||||||||||||||
| ● for live parts | ||||||||||||||||||||||||||
| — forwards | 10 mm | |||||||||||||||||||||||||
| — Backwards | 10 mm | |||||||||||||||||||||||||
| — downwards | 0 mm | |||||||||||||||||||||||||
| — at the side | 50 mm | |||||||||||||||||||||||||
| Connections/ Terminals | ||||||||||||||||||||||||||
| ● Type of electrical connection for main current circuit | screw-type terminals | |||||||||||||||||||||||||
| Type of connectable conductor cross-sections | ||||||||||||||||||||||||||
| ● for main contacts | ||||||||||||||||||||||||||
| — solid | 0.7 ... 35 mm², 2x (0.75 ... 25 mm²) | |||||||||||||||||||||||||
| — stranded | 0.7 ... 35 mm², 2x (0.75 ... 25 mm²) | |||||||||||||||||||||||||
| — finely stranded with core end processing | 0.75 ... 25 mm², 2x (0.75 ... 16 mm²) | |||||||||||||||||||||||||
| ● at AWG conductors for main contacts | 2x (30 ... 2) | |||||||||||||||||||||||||
| Connectable conductor cross-section for main contacts | ||||||||||||||||||||||||||
| ● single or multi-stranded | 0.7 ... 35 mm² | |||||||||||||||||||||||||
| ● stranded | 0.7 ... 35 mm² | |||||||||||||||||||||||||
| ● finely stranded with core end processing | 0.75 ... 25 mm² | |||||||||||||||||||||||||
| AWG number as coded connectable conductor cross section | ||||||||||||||||||||||||||
| ● for main contacts | 30 ... 2 | |||||||||||||||||||||||||
| Communication/ Protocol | ||||||||||||||||||||||||||
| ● protocol is supported PROFIBUS DP protocol | No | |||||||||||||||||||||||||
| ● protocol is supported PROFINET protocol | No | |||||||||||||||||||||||||
| product function bus communication | No | |||||||||||||||||||||||||
| Protocol is supported | ||||||||||||||||||||||||||
| ● AS-Interface protocol | No | |||||||||||||||||||||||||
| Inputs/ Outputs | ||||||||||||||||||||||||||
| ● number of digital inputs | 0 | |||||||||||||||||||||||||
| Certificates/ approvals | ||||||||||||||||||||||||||
| ||||||||||||||||||||||||||
| Further information | ||||||||||||||||||||||||||
Information- and Downloadcenter (Catalogs, Brochures,…) | ||||||||||||||||||||||||||
Industry Mall (Online ordering system) | ||||||||||||||||||||||||||
Cax online generator | ||||||||||||||||||||||||||
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) | ||||||||||||||||||||||||||
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) | ||||||||||||||||||||||||||
Characteristic: Tripping characteristics, I²t, Let-through current | ||||||||||||||||||||||||||
Further characteristics (e.g. electrical endurance, switching frequency) | ||||||||||||||||||||||||||
| last modified: | 08/13/2020 | |||||||||||||||||||||||||
| Product | ||
| Article Number (Market Facing Number) | 3RA1130-4FB35-0AF0 | |
| Product Description | Load feeder fuseless direct-on-line starting, 400 V AC 28...40 A, 110 V AC 50 Hz Size S2 Screw terminal on adapter Screw and snap-on mounting Type of coordination 2, Iq = 50 kA (also fulfills type of coordination 1) !!! Phased-out product !!! Successor is SIRIUS 3RA2 | |
| Product family | Not available | |
| Product Lifecycle (PLM) | PM490:Start of final year of support | |
| PLM Effective Date | Product discontinued since: 01.04.2020 | |
| Notes | Product is no longer available Sucessor:SIRIUS Innovation 3RA2 If you need assistance please contact our local Siemens office | |
| Price data | ||
| Price Group | 41D | |
| Surcharge for Raw Materials | None | |
| Metal Factor | LCO----- | |
| Delivery information | ||
| Export Control Regulations | ECCN : N / AL : N | |
| Standard lead time ex-works | 20 Day/Days | |
| Net Weight (kg) | 2,109 Kg | |
| Product Dimensions (W x L x H) | Not available | |
| Packaging Dimension | 65,00 x 302,00 x 192,00 | |
| Package size unit of measure | MM | |
| Quantity Unit | 1 Piece | |
| Packaging Quantity | 1 | |
| Additional Product Information | ||
| EAN | 4011209465459 | |
| UPC | Not available | |
| Commodity Code | 85364900 | |
| LKZ_FDB/ CatalogID | CC-IC10 | |
| Product Group | 3709 | |
| Group Code | R711 | |
| Country of origin | Germany | |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 | |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |
| Classifications | ||
| Not available | ||