SIEMENS 3NP1133-1BC13 3NP1133-1BC13 SIEMENS SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH00, 160 A, for Busbar system 8US 60 .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

3NP1133-1BC13 SIEMENS SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH00, 160 A, for Busbar system 8US 60 ..

3NP1133-1BC13

11331

SIEMENS

1 Pcs.

SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH00, 160 A, for Busbar system 8US 60 mm, flat terminal, Fuse monitoring: electronic EFM20, Cover level 32/70 mm DISCONNECTOR UNDER LOAD WITH FUSES 3 POLES, NH00, 160A FOR 60MM BUSBAR SYSTEMS WITH ELECTRONIC FUSE CONTROL, EFM 20. Manufactured to order. Non-Cancelable Non-Returnable.

Connectors > Fuse switch disconnector
SWITCHES-DISCONNECTORS

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH00, 160 A, for Busbar system 8US 60 mm, flat terminal, Fuse monitoring: electronic EFM20, Cover level 32/70 mm
Model
product brand nameSENTRON
product designation3NP1 fuse switch disconnector
design of the productcover level 32/70 mm
busbar designbusbar thickness 5 or 10 mm
design of the safety monitoringelectronic EFM 20
design of the actuating elementCover handle
design of the load switch / strip formNo
type of the driving mechanism / motor driveNo
General technical data
number of poles3
type of deviceFor 60 mm 8US busbar system
size of disconnecting link00 and 000
size of fuse linkNH000, NH00
let-through current / with closed switch / maximum permissible23 kA
mechanical service life (switching cycles) / typical2 000
power factor
● at AC-22 B0.65
● at AC-23 B0.45
● with capacitive load-0.25
fuse systemLV HRC fuse
degree of pollution2
Voltage
insulation voltage
● rated value690 V
● with degree of pollution 3 / at AC / rated value690 V
● with degree of pollution 2 / at AC / rated value1 000 V
power factor / at AC-21 B0.95
surge voltage resistance / rated value8 kV
operating voltage
● at AC / rated value / minimum230 V
● at AC / rated value / maximum690 V
Protection class
protection class IP
● with closed switch / with cover or cable lug coverIP40
● with closed switch / without cover or cable lug coverIP30
● openIP20
● on the frontIP40
Dissipation
power loss [W]
● with conventional rated thermal current / without fuse / per pole5 W
● with conventional rated thermal current / without fuse / per device15 W
● for rated value of the current / at AC / in hot operating state / per pole17 W
● of the fuse / per fuse / maximum12 W
Current
operational current
● at 35 °C / rated value160 A
● at 40 °C / rated value155 A
● at 45 °C / rated value145 A
● at 50 °C / rated value140 A
● at 55 °C / rated value133 A
● at AC / rated value160 A
● at AC-23 B / at 690 V / rated value35 A
● at AC-23 B / at 500 V / rated value63 A
● at AC-23 B / at 400 V / rated value160 A
● at AC-23 B / at 240 V / rated value160 A
● at AC-22 B / at 690 V / rated value125 A
● at AC-22 B / at 500 V / rated value160 A
● at AC-22 B / at 400 V / rated value160 A
● at AC-22 B / at 240 V / rated value160 A
● at AC-21 B / at 690 V / rated value160 A
● at AC-21 B / at 500 V / rated value160 A
● at AC-21 B / at 400 V / rated value160 A
● at AC-21 B / at 240 V / rated value160 A
let-through current / with high-speed activation / maximum permissible15 kA
Main circuit
operational current
● rated value160 A
● with capacitive load / at 400 V / rated value72 A
● with capacitive load / at 500 V / rated value55 A
Auxiliary circuit
number of CO contacts / for auxiliary contacts0
number of NC contacts / for auxiliary contacts0
number of NO contacts / for auxiliary contacts0
Suitability
suitability for use
● main switchNo
● switch disconnectorYes
● EMERGENCY OFF switchNo
● safety switchYes
● maintenance/repair switchYes
Product details
product feature / interlockYes
● product component / trip indicatorYes
● product function / phase failure monitoringYes
● product component / undervoltage releaseNo
● product component / undervoltage release with leading contactNo
product feature / sealableYes
product extension / auxiliary switchYes
product extension / optional
● locking capabilityYes
● motor driveNo
● voltage triggerNo
Product function
product function
● fuse monitoringYes
● overvoltage protection monitoringYes
Connections
arrangement of electrical connectors / for main current circuitother
connectable conductor cross-section / for main contacts
● solid or stranded / minimum2.5 mm²
● solid or stranded / maximum95 mm²
● stranded / minimum2.5 mm²
● stranded / maximum95 mm²
tightening torque / with screw-type terminals
● minimum10 N·m
● maximum12 N·m
type of connectable conductor cross-sections / of the laminated conductors / maximum24 x 12 mm
type of connection technologyFlat terminal
type of electrical connection / for main current circuitbusbar connection
Mechanical Design
height206.2 mm
width105.8 mm
depth177.2 mm
fastening methodbusbar
fastening method
● floor mountingNo
● 4-hole front mountingNo
● front mounting with central attachmentNo
● rail mountingYes
mounting positionhorizontal/vertical
busbar center-to-center spacing60 mm
net weight1.12 kg
Environmental conditions
ambient temperature / during operation
● minimum-25 °C
● maximum55 °C
ambient temperature / during storage
● minimum-50 °C
● maximum80 °C

Downloads and manuals

General Product Approval

Confirmation

CCC

UR

VDE

Miscellaneous

EAC

Declaration of ConformityTest CertificatesMarine / Shippingother

EC/EU-Declaration of Conformity

UK Declaration of Conformity

Type Test Certificates/Test Report

LR (Lloyds Register)

DNV-GL

Miscellaneous

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications
Date
5/8/2022


Additional data

Product
Article Number (Market Facing Number)3NP1133-1BC13
Product DescriptionSENTRON, Fuse switch disconnector 3NP1, 3-pole, NH00, 160 A, for Busbar system 8US 60 mm, flat terminal, Fuse monitoring: electronic EFM20, Cover level 32/70 mm
Product familyBasic Devices
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group14M / 1DL
Surcharge for Raw MaterialsNone
Metal FactorLCP-----
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works30 Day/Days
Net Weight (kg)1,397 Kg
Packaging Dimension245,00 x 257,00 x 134,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209700468
UPCNot available
Commodity Code85362090
LKZ_FDB/ CatalogIDLV10.1
Product Group5863
Group CodeP360
Country of originCzech Republic
Compliance with the substance restrictions according to RoHS directiveSince: 23.10.2008
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-14-01
eClass7.127-37-14-01
eClass827-37-14-01
eClass927-37-14-01
eClass9.127-37-14-01
ETIM5EC001040
ETIM6EC001040
ETIM7EC001040
ETIM8EC001040
UNSPSC1439-12-16-01
UNSPSC1539-12-22-33

ETIM data

ETIM: EC001040 - Fuse switch disconnector

Value Unit
Cable entry (EF000537) -
Version as main switch (EF006981) false
Version as safety switch (EF006985) true
Max. rated operation voltage Ue AC (EF007355) 690V
Rated permanent current Iu (EF001389) 160.0A
Conditioned rated short-circuit current Iq (EF001444) 80.0kA
Suitable for fuses (EF006692) NH000, NH00
Number of poles (EF001391) 3
With error protection (EF007384) true
Type of electrical connection of main circuit (EF006819) Rail connection
Equipped with connectors (EF011696) false
Suitable for floor mounting (EF007243) false
Suitable for front mounting (EF007246) false
Suitable for busbar mounting (EF007259) true
Type of control element (EF006976) Cover grip
Position control element (EF009410) Front side
Motor drive optional (EF007386) false
Motor drive integrated (EF006697) false
Version as emergency stop installation (EF006959) false
Degree of protection (IP), front side (EF003118) IP40
Rated operation power at AC-23, 400 V (EF007027) -kW
Rated short-time withstand current lcw (EF007050) -kA



Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.