View larger
3KL5740-1GB01 SIEMENS Switch disconnector with fuse in new design Iu 400 A, Ue 690 V, 4-pole for LV HRC fuse..
3KL5740-1GB01
57401
SIEMENS
1 Pcs.
Connectors > Switch disconnector
SWITCHES-DISCONNECTORS
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Industrial power control boards utilize high-capacity devices such as the Siemens 3KL5740-1GB01 switch disconnector with fuse to provide reliable circuit isolation and overcurrent protection simultaneously. Built for demanding electrical environments, these fused disconnects protect heavy machinery and distribution boards by breaking load currents and clearing short-circuit faults efficiently.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Version as main switch (EF006981): true
- Version as maintenance-/service switch (EF006986): true
- Version as safety switch (EF006985): true
- Version as emergency stop installation (EF006959): false
- Max. rated operation voltage Ue AC (EF007355): 690
- Rated permanent current Iu (EF001389): 400.0
- Rated permanent current at AC-23, 400 V (EF011777): 400
- Rated operation power at AC-23, 400 V (EF007027): 200.0
- Number of poles (EF001391): 4
- Motor drive optional (EF007386): false
- Motor drive integrated (EF006697): false
- Voltage release optional (EF007491): false
- Device construction (EF008240): Built-in device fixed built-in technique
- Suitable for floor mounting (EF007243): FALSE
- Suitable for front mounting 4-hole (EF007247): false
- Suitable for front mounting centre (EF007248): false
More info
▲ETIM: EC000216 - Switch disconnector
| Value | Unit | |
|---|---|---|
| Colour control element (EF007167) | - | |
| Rated operating voltage (EF001435) | - | V |
| Degree of protection (NEMA) (EF011959) | - | |
| Rated permanent current at AC-21, 400 V (EF009165) | - | A |
| Version as reversing switch (EF009408) | - | |
| Rated short-time withstand current lcw (EF007050) | - | kA |
| Switching power at 400 V (EF009166) | - | kW |
| Number of switches (EF005586) | - | |
| Version as main switch (EF006981) | true | |
| Version as maintenance-/service switch (EF006986) | true | |
| Version as safety switch (EF006985) | true | |
| Version as emergency stop installation (EF006959) | false | |
| Max. rated operation voltage Ue AC (EF007355) | 690 | V |
| Rated permanent current Iu (EF001389) | 400.0 | A |
| Rated permanent current at AC-23, 400 V (EF011777) | 400 | A |
| Rated operation power at AC-23, 400 V (EF007027) | 200.0 | kW |
| Number of poles (EF001391) | 4 | |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 | |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 | |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 | |
| Motor drive optional (EF007386) | false | |
| Motor drive integrated (EF006697) | false | |
| Voltage release optional (EF007491) | false | |
| Device construction (EF008240) | Built-in device fixed built-in technique | |
| Suitable for floor mounting (EF007243) | FALSE | |
| Suitable for front mounting 4-hole (EF007247) | false | |
| Suitable for front mounting centre (EF007248) | false | |
| Suitable for distribution board installation (EF007262) | false | |
| Suitable for intermediate mounting (EF007264) | false | |
| Type of control element (EF006976) | Other | |
| Interlockable (EF006281) | true | |
| Type of electrical connection of main circuit (EF006819) | Other | |
| Degree of protection (IP), front side (EF003118) | IP00 | |
| Conditioned rated short-circuit current Iq (EF001444) | - | kA |
| Rated operation power at AC-3, 400 V (EF001364) | - | kW |
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3KL5740-1GB01 | ||||||||||||||||||||||||||||||||||||
| Product Description | Switch disconnector with fuse in new design Iu=400 A, Ue = 690 V, 4-pole for LV HRC fuse Sz. 1 and 2 4th pole selectable, without Fuse with door operating mechanism 8UC7 Handle dark blue/blue-green Basic masking frame light gray | ||||||||||||||||||||||||||||||||||||
| Product family | Not available | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | ||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 31.08.2018 | ||||||||||||||||||||||||||||||||||||
| Notes | Sucessor:3KF4440-0MF11, different dimensions, some deviating technical values. | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Price Group | 12S | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 15 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 6,836 Kg | ||||||||||||||||||||||||||||||||||||
| Product Dimensions (W x L x H) | Not available | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 209,00 x 309,00 x 252,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209739239 | ||||||||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362090 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | LV10.1 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5853 | ||||||||||||||||||||||||||||||||||||
| Group Code | P360 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.06.2007 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||