View larger
3KL5730-1AG01 SIEMENS Switch disconnector with fuse in new design Iu 400 A, Ue 690 V, 3-pole for BS88 fuse f..
3KL5730-1AG01
57301
SIEMENS
1 Pcs.
Connectors > Switch disconnector
SWITCHES-DISCONNECTORS
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Siemens 3KL5730-1AG01 Switch disconnector with fuse in new design Iu 400 A, Ue 690 V, 3-pole for BS88 fuse f.. is utilized in industrial power distribution setups to safely isolate circuits and protect against overcurrent conditions during maintenance operations. These disconnectors provide manual switching capability alongside integrated fuse protection to ensure safe de-energization of heavy machinery and switchboards.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Version as main switch (EF006981): true
- Version as maintenance-/service switch (EF006986): true
- Version as safety switch (EF006985): true
- Version as emergency stop installation (EF006959): true
- Max. rated operation voltage Ue AC (EF007355): 690
- Rated permanent current Iu (EF001389): 400.0
- Rated permanent current at AC-23, 400 V (EF011777): 400
- Rated operation power at AC-23, 400 V (EF007027): 200.0
- Number of poles (EF001391): 3
- Motor drive optional (EF007386): false
- Motor drive integrated (EF006697): false
- Voltage release optional (EF007491): false
- Device construction (EF008240): Built-in device fixed built-in technique
- Suitable for floor mounting (EF007243): FALSE
- Suitable for front mounting 4-hole (EF007247): false
- Suitable for front mounting centre (EF007248): false
More info
▲ETIM: EC000216 - Switch disconnector
| Value | Unit | |
|---|---|---|
| Switching power at 400 V (EF009166) | - | kW |
| Rated operating voltage (EF001435) | - | V |
| Rated short-time withstand current lcw (EF007050) | - | kA |
| Version as reversing switch (EF009408) | - | |
| Number of switches (EF005586) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Colour control element (EF007167) | - | |
| Rated permanent current at AC-21, 400 V (EF009165) | - | A |
| Version as main switch (EF006981) | true | |
| Version as maintenance-/service switch (EF006986) | true | |
| Version as safety switch (EF006985) | true | |
| Version as emergency stop installation (EF006959) | true | |
| Max. rated operation voltage Ue AC (EF007355) | 690 | V |
| Rated permanent current Iu (EF001389) | 400.0 | A |
| Rated permanent current at AC-23, 400 V (EF011777) | 400 | A |
| Rated operation power at AC-23, 400 V (EF007027) | 200.0 | kW |
| Number of poles (EF001391) | 3 | |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 | |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 | |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 | |
| Motor drive optional (EF007386) | false | |
| Motor drive integrated (EF006697) | false | |
| Voltage release optional (EF007491) | false | |
| Device construction (EF008240) | Built-in device fixed built-in technique | |
| Suitable for floor mounting (EF007243) | FALSE | |
| Suitable for front mounting 4-hole (EF007247) | false | |
| Suitable for front mounting centre (EF007248) | false | |
| Suitable for distribution board installation (EF007262) | false | |
| Suitable for intermediate mounting (EF007264) | false | |
| Type of control element (EF006976) | Other | |
| Interlockable (EF006281) | true | |
| Type of electrical connection of main circuit (EF006819) | Other | |
| Degree of protection (IP), front side (EF003118) | IP00 | |
| Conditioned rated short-circuit current Iq (EF001444) | - | kA |
| Rated operation power at AC-3, 400 V (EF001364) | - | kW |
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3KL5730-1AG01 | ||||||||||||||||||||||||||||||||||||
| Product Description | Switch disconnector with fuse in new design Iu=400 A, Ue = 690 V, 3-pole for BS88 fuse form B1/B3 basic version without 8UC6 handle and shaft | ||||||||||||||||||||||||||||||||||||
| Product family | Not available | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | ||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 31.08.2018 | ||||||||||||||||||||||||||||||||||||
| Notes | Sucessor:3KF4340-0MF11, different dimensions, some deviating technical values. | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Price Group | 12S | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 15 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 5,666 Kg | ||||||||||||||||||||||||||||||||||||
| Product Dimensions (W x L x H) | Not available | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 209,00 x 309,00 x 252,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209464209 | ||||||||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362090 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | LV10.1 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5853 | ||||||||||||||||||||||||||||||||||||
| Group Code | P360 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Given | ||||||||||||||||||||||||||||||||||||
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||