View larger
3KL5030-1GG01 SIEMENS Switch disconnector with fuse in new design Iu 63 A, Ue 690 V, 3-pole for BS88 fuse fo..
3KL5030-1GG01
50301
SIEMENS
1 Pcs.
Connectors > Switch disconnector
SWITCHES-DISCONNECTORS
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Siemens 3KL5030-1GG01 Switch disconnector with fuse in new design Iu 63 A, Ue 690 V, 3-pole for BS88 fuse fo.. is a heavy-duty industrial switching device designed to safely isolate electrical circuits under load while offering integrated short-circuit protection via fuses. Such disconnectors are commonly installed in main distribution panels to protect downstream wiring and equipment.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Version as main switch (EF006981): true
- Version as maintenance-/service switch (EF006986): true
- Version as safety switch (EF006985): true
- Version as emergency stop installation (EF006959): false
- Max. rated operation voltage Ue AC (EF007355): 690
- Rated permanent current Iu (EF001389): 63.0
- Rated permanent current at AC-23, 400 V (EF011777): 63
- Rated operation power at AC-23, 400 V (EF007027): 30.0
- Number of poles (EF001391): 3
- Motor drive optional (EF007386): false
- Motor drive integrated (EF006697): false
- Voltage release optional (EF007491): false
- Device construction (EF008240): Built-in device fixed built-in technique
- Suitable for floor mounting (EF007243): FALSE
- Suitable for front mounting 4-hole (EF007247): false
- Suitable for front mounting centre (EF007248): false
More info
▲ETIM: EC000216 - Switch disconnector
| Value | Unit | |
|---|---|---|
| Rated permanent current at AC-21, 400 V (EF009165) | - | A |
| Number of switches (EF005586) | - | |
| Colour control element (EF007167) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Rated short-time withstand current lcw (EF007050) | - | kA |
| Rated operating voltage (EF001435) | - | V |
| Switching power at 400 V (EF009166) | - | kW |
| Version as reversing switch (EF009408) | - | |
| Version as main switch (EF006981) | true | |
| Version as maintenance-/service switch (EF006986) | true | |
| Version as safety switch (EF006985) | true | |
| Version as emergency stop installation (EF006959) | false | |
| Max. rated operation voltage Ue AC (EF007355) | 690 | V |
| Rated permanent current Iu (EF001389) | 63.0 | A |
| Rated permanent current at AC-23, 400 V (EF011777) | 63 | A |
| Rated operation power at AC-23, 400 V (EF007027) | 30.0 | kW |
| Number of poles (EF001391) | 3 | |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 | |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 | |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 | |
| Motor drive optional (EF007386) | false | |
| Motor drive integrated (EF006697) | false | |
| Voltage release optional (EF007491) | false | |
| Device construction (EF008240) | Built-in device fixed built-in technique | |
| Suitable for floor mounting (EF007243) | FALSE | |
| Suitable for front mounting 4-hole (EF007247) | false | |
| Suitable for front mounting centre (EF007248) | false | |
| Suitable for distribution board installation (EF007262) | false | |
| Suitable for intermediate mounting (EF007264) | false | |
| Type of control element (EF006976) | Other | |
| Interlockable (EF006281) | true | |
| Type of electrical connection of main circuit (EF006819) | Other | |
| Degree of protection (IP), front side (EF003118) | IP00 | |
| Conditioned rated short-circuit current Iq (EF001444) | - | kA |
| Rated operation power at AC-3, 400 V (EF001364) | - | kW |
| Product | |||||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3KL5030-1GG01 | ||||||||||||||||||||||||||||||||||||
| Product Description | Switch disconnector with fuse in new design Iu=63 A, Ue = 690 V, 3-pole for BS88 fuse form A2/A3 with door operating mechanism 8UC7 Handle dark blue/blue-green Basic masking frame light gray | ||||||||||||||||||||||||||||||||||||
| Product family | Not available | ||||||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM400:Phase Out Started | ||||||||||||||||||||||||||||||||||||
| PLM Effective Date | Product phase-out since: 31.08.2018 | ||||||||||||||||||||||||||||||||||||
| Notes | Sucessor:3KF1306-0MB11, different dimensions, some deviating technical values. | ||||||||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||||||||
| Price Group | 12S | ||||||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||||||||
| Metal Factor | LAO----- | ||||||||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 15 Day/Days | ||||||||||||||||||||||||||||||||||||
| Net Weight (kg) | 1,391 Kg | ||||||||||||||||||||||||||||||||||||
| Product Dimensions (W x L x H) | Not available | ||||||||||||||||||||||||||||||||||||
| Packaging Dimension | 258,00 x 276,00 x 132,00 | ||||||||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||||||||
| EAN | 4011209739154 | ||||||||||||||||||||||||||||||||||||
| UPC | Not available | ||||||||||||||||||||||||||||||||||||
| Commodity Code | 85362010 | ||||||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | LV10.1 | ||||||||||||||||||||||||||||||||||||
| Product Group | 5853 | ||||||||||||||||||||||||||||||||||||
| Group Code | P360 | ||||||||||||||||||||||||||||||||||||
| Country of origin | Germany | ||||||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.06.2007 | ||||||||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||