PHOENIX CONTACT VS-M12FSBP-OE-94C-LI/2,0X VS-M12FSBP-OE-94C-LI/2,0X 1260718 PHOENIX CONTACT Conect. plug. to be apar. wall poster., protection index: .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

VS-M12FSBP-OE-94C-LI/2,0X 1260718 PHOENIX CONTACT Conect. plug. to be apar. wall poster., protection index: ..

VS-M12FSBP-OE-94C-LI/2,0X

1260718

PHOENIX CONTACT

1 Pcs.

Conect. plug. to be apar. wall poster., protection index: IP65/IP67, cable length: 2 m, number of poles: 8, connection type: Cable connection, Ethernet, The item does not contain lead according to the RoHS II directive without exception 6c (Pb&lt.; 0.1%) Connect. plug. for apar. poster wall, Ethernet, 8-pole, PUR, aqua blue RAL5021, Female mount Straight M12, encoding: A SPEEDCON / IP67, A free cable end, cable length: 2 m, The article does not contain lead according to the RoHS II directive without the exception 6c (Pb< 0.1%) Device connector, rear mounting, Ethernet, 8-position, PUR, water blue RAL 5021, Flush-type female connector straight M12 SPEEDCON, coding: A / IP67, on free cable end, cable length: 2 m, Item is lead-free in accordance with RoHS II without Exemption 6c (Pb <0.1%)

Cables > Circular connector, mounting (with cable)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
GeneralThe electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.

Product properties
Product typeData cable preassembled
Sensor typeEthernet
Number of positions8
No. of cable outlets1
Shieldedyes
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Interfaces
Signal type/categoryEthernet

Electrical properties
Rated surge voltage0.8 kV
Contact resistance≤ 3 mΩ
Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
Nominal current IN2 A
Transmission mediumCopper
Wave impedance100 Ω

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Material specifications
Flammability rating according to UL 94V2
Seal materialFKM
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Outer sheath, materialPUR
Conductor materialBare Cu litz wires

Connector
Connection 1
TypeFlush-type female connector straight M12 SPEEDCON / IP67
Number of positions8
Locking typeSPEEDCON
Coding typeA (Standard)
Degree of protectionIP67
Connection 2
Typefree cable end

Cable/line
Cable length2 m
Ethernet drag chain CAT5, 4-pair [94C]
Dimensional drawingolnmofyrwi.jpg
Cable weight57 kg/km
UL AWM Style20963 (80°C/30 V)
Number of positions8
Shieldedyes
Cable typeEthernet drag chain CAT5, 4-pair [94C]
Conductor structure4x2xAWG26/19, S/UTP
Signal runtime5.3 ns/m
Conductor structure signal line19x 0.10 mm
AWG signal line26
Conductor cross section4x 2x 0.14 mm²
Wire diameter incl. insulation1 mm
External cable diameter6.9 mm +0.1 mm ... 0.2 mm
Outer sheath, materialPUR
External sheath, colorwater blue RAL 5021
Conductor materialBare Cu litz wires
Material wire insulationPP
Single wire, colorwhite/blue-blue, white/orange-orange, white/green-green, white/brown-brown
Thickness, outer sheath0.85 mm
Twisted pairs2 cores to the pair
Overall twistFour pairs and four fillers to the core
Optical shield covering90 %
Insulation resistance≥ 500 MΩ*km
Coupling resistance≤ 100.00 mΩ/m (at 10 MHz)
Loop resistance≤ 290.00 Ω/km
Wave impedance100 Ω ±5 Ω (at 100 MHz)
Cable capacityapprox. 50 nF/km (at 1 kHz)
Nominal voltage, cable≤ 100 V
Test voltage Core/Core700 V (50 Hz, 1 min.)
Test voltage Core/Shield700 V (50 Hz, 1 min.)
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation8 x D
Smallest bending radius, fixed installation28 mm
Smallest bending radius, movable installation56 mm
Max. bending cycles5000000
Tensile strength≤ 100 N
Near end crosstalk attenuation (NEXT)65.3 dB (with 1 MHz)
56.3 dB (at 4 МHz)
50.3 dB (at 10 MHz)
47.2 dB (at 16 MHz)
45.8 dB (at 20 МHz)
42.9 dB (at 31.25 МHz)
38.4 dB (at 62.5 МHz)
35.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)62.3 dB (with 1 MHz)
53.3 dB (at 4 МHz)
47.3 dB (at 10 MHz)
44.2 dB (at 16 MHz)
42.8 dB (at 20 МHz)
39.9 dB (at 31.25 МHz)
35.4 dB (at 62.5 МHz)
32.3 dB (at 100 MHz)
Return attenuation (RL)23 dB (at 4 МHz)
24.1 dB (at 8 МHz)
25 dB (at 10 MHz)
25 dB (at 16 MHz)
25 dB (at 20 МHz)
23.6 dB (at 31.25 МHz)
21.5 dB (at 62.5 МHz)
20.1 dB (at 100 MHz)
Shield attenuation3.2 dB (with 1 MHz)
6 dB (at 4 МHz)
9.5 dB (at 10 MHz)
12.1 dB (at 16 MHz)
13.6 dB (at 20 МHz)
17.1 dB (at 31.25 МHz)
24.8 dB (at 62.5 МHz)
32 dB (at 100 MHz)
Halogen-freeaccording to IEC 60754-1
Flame resistanceaccording to IEC 60332-1-2
Resistance to oilin accordance with EN 60811-2-1
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (Cable, flexible installation)
Ambient temperature (installation)-20 °C ... 80 °C

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP67 (When plugged in)
IP65 (When plugged in)
IP65/IP67
Ambient temperature (operation)-25 °C ... 85 °C (Plug / socket)
-40 °C ... 85 °C (without mechanical actuation)
-25 °C ... 85 °C (Cable, flexible installation)

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.