PHOENIX CONTACT VIP-CAB-FLK40/FS/NA/HF/ 2,0M VIP-CAB-FLK40/FS/NA/HF/ 2,0M 1116410 PHOENIX CONTACT Assembled, halogen-free round cable connection 1: IDC/F.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

VIP-CAB-FLK40/FS/NA/HF/ 2,0M 1116410 PHOENIX CONTACT Assembled, halogen-free round cable connection 1: IDC/F..

VIP-CAB-FLK40/FS/NA/HF/ 2,0M

1116410

PHOENIX CONTACT

2 Pcs.

Assembled, halogen-free round cable; connection 1: IDC/FLK socket strip (1x 40-position, 180 °-Out put); connection 2: Single wires (40-position); cable length: 5 m Ready-made, shielded and halogen-free round cable; Connection 1: Female IDC/FLK connection (1x 40-poles, 180°-output); connection 2: Single conductors (40-poles); Cable length: 2 m

Cables > PLC connection cable
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1116410
Packing unit1
GTIN4063151042165
Custom tariff number85444290

Drawings



Diagram

Diagram
Maximum permissible current per path in uncoiled state

Back to top

Ambient conditions

Ambient temperature (operation)-40 °C ... 70 °C (fixed installation)
-10 °C ... 70 °C (flexible installation)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum altitude≤ 2000 m
Degree of protectionIP00
≥ IP54 (Installation location)
Back to top

General

Max. permissible operating voltage25 V AC
60 V DC
Max. current carrying capacity per path1 A (50 °C)
0.6 A (70°C)
Length of cable5 m
External cable diameter9.9 mm ±0,3 mm
Single wire, cross section0.14 mm²
Single wire, cross section [AWG]26
Single wire, number of litz wires7
Single wire, materialCu tin-plated
Wire diameter incl. insulation1 mm ±0.03 mm
Smallest bending radius, fixed installation82 mm
Smallest bending radius, movable installation153 mm
Bending cycles5000 (at a radius of ≥ 15x outside diameter)
Cable, preassemblyInsulation displacement, IEC 60352-4/DIN EN 60352-4
Shieldingno
Cable insulation resistance≥ 20 MΩ/km (20 °C)
Cable resistance≤ 145 Ω/km (20 °C)
Outer sheath, materialFR-PE, halogen-free
External sheath, colorgray RAL 7035
Nominal operating mode100% operating factor
Back to top

Connection data

Connection nameField level
Connection methodSingle wires
Number of positions40
Back to top

Connection data 2

Connection nameController level
Connection in acc. with standardIEC 60603-13
Connection methodIDC/FLK socket strip
Number of connections1
Number of positions40
Exit angle180 °
Insertion/withdrawal cycles> 50
Pitch2.54 mm
Back to top

Standards and Regulations

Flame resistanceIEC 60332-1-2
VDE 0842, Part 332-1-2
IEC 60332-3-22
Resistance to oilagainst occasional splashes
Gasoline resistanceagainst occasional splashes
DesignationAir clearances and creepage distances
Standards/regulationsDIN EN 50178
Rated insulation voltage63 V
Rated surge voltage0.6 kV
InsulationFunctional insulation
Pollution degree2
Overvoltage categoryII
Back to top

Supported controller

Controlleruniversal
Back to top

Color code

Connector 1 = connector 2 (optional) = wire colorIDC/FLK50 (1) = IDC/FLK50 (1) = black
IDC/FLK50 (2) = IDC/FLK50 (2) = brown
IDC/FLK50 (3) = IDC/FLK50 (3) = red
IDC/FLK50 (4) = IDC/FLK50 (4) = orange
IDC/FLK50 (5) = IDC/FLK50 (5) = yellow
IDC/FLK50 (6) = IDC/FLK50 (6) = green
IDC/FLK50 (7) = IDC/FLK50 (7) = blue
IDC/FLK50 (8) = IDC/FLK50 (8) = violet
IDC/FLK50 (9) = IDC/FLK50 (9) = gray
IDC/FLK50 (10) = IDC/FLK50 (10) = white
IDC/FLK50 (11) = IDC/FLK50 (11) = white-black
IDC/FLK50 (12) = IDC/FLK50 (12) = white-brown
IDC/FLK50 (13) = IDC/FLK50 (13) = white-red
IDC/FLK50 (14) = IDC/FLK50 (14) = white-orange
IDC/FLK50 (15) = IDC/FLK50 (15) = white-yellow
IDC/FLK50 (16) = IDC/FLK50 (16) = white-green
IDC/FLK50 (17) = IDC/FLK50 (17) = white-blue
IDC/FLK50 (18) = IDC/FLK50 (18) = white-violet
IDC/FLK50 (19) = IDC/FLK50 (19) = white-gray
IDC/FLK50 (20) = IDC/FLK50 (20) = brown-black
IDC/FLK50 (21) = IDC/FLK50 (21) = brown-red
IDC/FLK50 (22) = IDC/FLK50 (22) = brown-orange
IDC/FLK50 (23) = IDC/FLK50 (23) = brown-yellow
IDC/FLK50 (24) = IDC/FLK50 (24) = brown-green
IDC/FLK50 (25) = IDC/FLK50 (25) = brown-blue
IDC/FLK50 (26) = IDC/FLK50 (26) = brown-violet
IDC/FLK50 (27) = IDC/FLK50 (27) = brown-gray
IDC/FLK50 (28) = IDC/FLK50 (28) = brown-white
IDC/FLK50 (29) = IDC/FLK50 (29) = green-black
IDC/FLK50 (30) = IDC/FLK50 (30) = green-brown
IDC/FLK50 (31) = IDC/FLK50 (31) = green-red
IDC/FLK50 (32) = IDC/FLK50 (32) = green-orange
IDC/FLK50 (33) = IDC/FLK50 (33) = green-blue
IDC/FLK50 (34) = IDC/FLK50 (34) = green-violet
IDC/FLK50 (35) = IDC/FLK50 (35) = green-gray
IDC/FLK50 (36) = IDC/FLK50 (36) = green-white
IDC/FLK50 (37) = IDC/FLK50 (37) = yellow-black
IDC/FLK50 (38) = IDC/FLK50 (38) = yellow-brown
IDC/FLK50 (39) = IDC/FLK50 (39) = yellow-red
IDC/FLK50 (40) = IDC/FLK50 (40) = yellow-orange
Back to top

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 8.027249205
eCl@ss 9.027242220
Back to top

ETIM

ETIM 5.0EC000237
Back to top

ETIM for 1116410 PLC's (EC000237)
Feature Name Feature Value
Function (EF000030) PLC - other devices
Length (EF001438) 2 m
Suitable for input board PLC (EF008271) No
Suitable for output card PLC (EF008272) No
Suitable for digital signals (EF008273) No
Suitable for analogue signals (EF008274) No
Type of electrical connection, field-sided (EF005525) Other
Type of electrical connection, box-sided (EF005524) Other
Number of poles (EF001391) 40