PHOENIX CONTACT

50 Pcs.

Feed-through terminal block Feed-through terminal, nominal voltage: 800 V, nominal current: 24 A, 1st floor, right-hand connection, connection type: Screw connection, Sizing cross-section: 2.5 mm², cross-section: 0.2 mm² - 4 mm², connection type: Flat plug connection, mounting: NS 35/7.5, NS 35/15, color: gray

Automation > Feed-through terminal block
Enclosures connectivity

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey0852067
Packing unit50 pc
GTIN4017918197599
Weight per Piece (excluding packing)9.770 g
Custom tariff number85369010
Country of originPL (Poland)

General

Number of levels1
Number of connections4
Nominal cross section2.5 mm²
Colorgray
Insulating materialPA
Flammability rating according to UL 94V2
Rated surge voltage8 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupI
Maximum power dissipation for nominal condition0.77 W
Connection methodScrew connection
Maximum load current32 A (with 4 mm² conductor cross section)
Nominal current IN24 A
Nominal voltage UN800 V
Connection methodSlip-on connection
Open side panelYes
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width6.2 mm
Length72 mm
Height NS 35/7,539.5 mm
Height NS 35/1547 mm
End cover width2.2 mm

Connection data

Connection methodScrew connection
Screw threadM3
Tightening torque, min0.6 Nm
Tightening torque max0.8 Nm
Stripping length8 mm
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Min. AWG conductor cross section, flexible24
Max. AWG conductor cross section, flexible14
Conductor cross section flexible, with ferrule without plastic sleeve min.0.25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.4 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.0.25 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.2.5 mm²
Cross section with insertion bridge, solid max.2.5 mm²
Cross section with insertion bridge, stranded max.2.5 mm²
2 conductors with same cross section, solid min.0.2 mm²
2 conductors with same cross section, solid max.1.5 mm²
2 conductors with same cross section, stranded min.0.2 mm²
2 conductors with same cross section, stranded max.1.5 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min.0.25 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max.1 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min.0.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max.1.5 mm²
Connection methodSlip-on connection

Standards and Regulations

Connection in acc. with standardCSA
Flammability rating according to UL 94V2
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.