Type 2 surge arrester Universal plug-in surge and lightning current protection device equipped with varistors for 48–60 V DC applications with two conductors and grounding, with remote indication contact

Automation > Surge protection device for power supply systems
Trabtech (TT)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2909630
Packing unit1 pc
NoteMade to Order (non-returnable)
GTIN4055626370538
Weight per Piece (excluding packing)222.220 g
Custom tariff number85363010
Country of originUS (United States)

Dimensions

Height40.6 mm
Width70.6 mm
Depth85.6 mm
Height unit1 U

Ambient conditions

Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

General

IEC test classificationII
T2
EN typeT2
IEC power supply systemTN-S
Mode of protectionL-N
N-PE
Mounting typePanel mount
Colorgray
Housing materialPA 6.6
PBT
Degree of pollution2
Flammability rating according to UL 94V-0
TypeDIN rail module, two-section, divisible
Surge protection fault messageOptical, remote indicator contact

Additional descriptions

NoteFor installation into a touch protected cabinet. For applications with UC> 500 V distances at the side and distances at the connection area must be minimum of 5 mm between different active parts including earthed parts.

Protective circuit

Nominal voltage UN-48 V DC ±10 % (RRH)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC75 V AC
100 V DC
Rated load current IL80 A
Residual current IPE≤ 0.45 mA
Standby power consumption PC≤ 35 mVA
Nominal discharge current In(8/20) µs15 kA
Maximum discharge current Imax(8/20) µs40 kA
Short-circuit current rating ISCCR25 kA
Voltage protection level Up≤ 0.55 kV
Residual voltage Ures≤ 0.55 kV (at In)
≤ 0.425 kV (at 10 kA)
≤ 0.325 kV (at 5 kA)
≤ 0.275 kV (at 3 kA)
TOV behavior at UT100 V AC (5 s / withstand mode)
Response time tA≤ 25 ns
Max. backup fuse with V-type through wiring80 A AC (gG - 16 mm²)
Max. backup fuse with branch wiring160 A AC (gG)

Indicator/remote signaling

Switching functionPDT contact
Operating voltage5 V AC ... 250 V AC
125 V AC (UL)
125 V DC (200 mA DC)
Operating current5 mA AC ... 1.5 A
1 A (UL)
1 A (30 V DC)
Connection methodPush-in spring connection
Stripping length6 mm
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.0.5 mm²
Conductor cross section solid min.0.14 mm²
Conductor cross section solid max.0.5 mm²
Conductor cross section AWG24 ... 20 (UL)

Connection data

Connection methodScrew connection
Screw threadM5
Tightening torque2.5 Nm ... 3 Nm
22 lbf-in. ... 26.5 lbf-in. (UL)
Stripping length16 mm
Conductor cross section flexible min.1.5 mm²
Conductor cross section flexible max.25 mm²
Conductor cross section solid min.1.5 mm²
Conductor cross section solid max.35 mm²
Conductor cross section AWG15 ... 2
10 ... 2 (UL)

UL specifications

SPD Type4CA
Maximum continuous operating voltage MCOV (L-N)75 V AC
100 V DC
Nominal voltage60 V DC
Mode of protectionN-G
L-N
(L+) - (L-)
(L+) - G
(L-) - G

UL indicator/remote signaling

Operating voltage125 V AC
Operating current1 A AC
Conductor cross section AWG30 ... 14

UL connection data

Conductor cross section AWG10 ... 2
Tightening torque22 lbf-in. ... 26.5 lbf-in.

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


ETIM for 2909630 Earthing, lightning and surge protection (EC000941)
Feature Name Feature Value
System configuration DC (EF009926) No
System configuration IT (EF009927) No
System configuration TN (EF009928) No
System configuration TN-C (EF009929) No
System configuration TN-C-S (EF009933) No
System configuration TN-S (EF009930) Yes
System configuration TT (EF009931) No
System configuration other (EF009932) No
Nominal discharge surge current (8/20) (EF004214) 15 kA
Max. discharge surge current (8/20) (EF012274) 40 kA
Max. continuous voltage AC (EF004198) 75 V
Voltage protection level L-N (EF004236) 0.55 kV
Max. overcurrent protection device, parallel connection (fuse) (EF015962) 160 A
Max. overcurrent protection device, series connection (fuse) (EF015963) 80 A
Short-circuit breaking capacity (Isccr) (EF012627) 25 kA
Integrated backup fuse (EF008797) Yes
Leakage-current free (EF016002) No
With remote signalling contact (EF000422) Yes
Signalling at the device (EF004241) Optic
Category type 2 (EF004230) Yes
Degree of protection (IP) (EF005474) IP20