PHOENIX CONTACT VAL-SEC-T2-GDT-400DC-P VAL-SEC-T2-GDT-400DC-P 1052632 PHOENIX CONTACT Type 2 surge protection plug View larger
Images are for illustrative purposes only. Please refer to data sheet for details

VAL-SEC-T2-GDT-400DC-P 1052632 PHOENIX CONTACT Type 2 surge protection plug

VAL-SEC-T2-GDT-400DC-P

1052632

PHOENIX CONTACT

1 Pcs.

Type 2 surge protection plug Replacement connector for surge protection device from the VALVETRAB SEC product line for DC power sources. Ground the path for 48 and 120 V DC. Replacement connectors for VALVETRAB SEC series surge arresters for DC power sources. Protection of the range to earth for 48 and 120 V DC.

Automation > Accessories/spare parts for surge protection power supply systems
Trabtech (TT)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1052632
Packing unit1 pc
NoteMade to Order (non-returnable)
GTIN4055626676548
Weight per Piece (excluding packing)36.000 g
Custom tariff number85363030
Country of originDE (Germany)

Dimensions

Height46.4 mm
Width11.7 mm
Depth59.4 mm
Horizontal pitch0.6 Div.

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 6000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

General

IEC test classificationII
T2
EN typeT2
Mode of protection(DC+/DC-) - PE
Mounting typeon base element
Colorlight grey RAL 7035
Housing materialPA 6.6-FR 20% GF
PBT-FR
Degree of pollution2
Flammability rating according to UL 94V-0
TypeMale
Number of positions1
Surge protection fault messageoptical

Additional descriptions

NoteThe VAL-SEC-T2-GDT-400DC-P protective plug (order No.: 1052632) is only to be used in series connection with a VAL-SEC-T2-48DC-P (order No.: 2907877) or VAL-SEC-T2- 120DC-P (order No.: 2907878). It is not designed for direct use on mains voltage.
Uagn ≥ 300 V

Protective circuit

Residual current IPE≤ 5 µA
Nominal discharge current In(8/20) µs20 kA
Maximum discharge current Imax(8/20) µs40 kA
Voltage protection level Up≤ 0.95 kV
Residual voltage Ures≤ 0.4 kV (at In)
≤ 0.4 kV (at 10 kA)
≤ 0.4 kV (at 5 kA)
≤ 0.4 kV (at 4 kA)
≤ 0.4 kV (at 2 kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs≤ 0.95 kV
Response time tA≤ 100 ns

Connection data

Connection methodpluggable

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values