PHOENIX CONTACT VAL-SEC-T2-350VF-P VAL-SEC-T2-350VF-P 2909596 PHOENIX CONTACT Type 2 surge protection plug View larger
Images are for illustrative purposes only. Please refer to data sheet for details

VAL-SEC-T2-350VF-P 2909596 PHOENIX CONTACT Type 2 surge protection plug

VAL-SEC-T2-350VF-P

2909596

PHOENIX CONTACT

1 Pcs.

Type 2 surge protection plug Leak-proof replacement connector for surge protection devices from the VALVETRAB SEC product line for L-N and L-PEN paths.

Automation > Accessories/spare parts for surge protection power supply systems
Trabtech (TT)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Replacement plug free of leakage current for surge protective devices from the VALVETRAB SEC product range for L-N and L-PEN paths.

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %

General

IEC test classificationII
T2
EN typeT2
IEC power supply systemTN
TT
Mode of protectionL-N
L-PEN
Mounting typeon base element
Colorlight grey RAL 7035
Housing materialPA 6.6-FR 20% GF
PBT-FR
Degree of pollution2
Flammability rating according to UL 94V-0
TypeMale
Number of positions1
Surge protection fault messageoptical

Protective circuit

Nominal voltage UN240 V AC (TN)
240 V AC (TT)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC350 V AC
Nominal discharge current In(8/20) µs10 kA
Maximum discharge current Imax(8/20) µs20 kA
Short-circuit current rating ISCCR50 kA
Voltage protection level Up≤ 1.5 kV
Residual voltage Ures≤ 1.35 kV (at In)
≤ 1.1 kV (at 5 kA)
≤ 0.95 kV (at 2 kA)
≤ 0.9 kV (At 1 kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs≤ 1.5 kV
TOV behavior at UT457 V AC (5 s / withstand mode)
457 V AC (120 min / withstand mode)
Response time tA≤ 100 ns
Max. backup fuse with branch wiring200 A (gG)

Connection data

Connection methodpluggable

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012

eCl@ss

eCl@ss 5.127130801
eCl@ss 6.027130805
eCl@ss 8.027130890
eCl@ss 9.027130890

ETIM

ETIM 5.0EC002496
ETIM 6.0EC000941

UNSPSC

UNSPSC 13.239121620

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.