View larger
VAL-MS-T1/T2 BE/O-FM
2905652
PHOENIX CONTACT
12 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2905652 |
|---|---|
| Packing unit | 12 pc |
| Minimum order quantity | 12 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 39 (C-4-2017) |
| GTIN | 4046356983372 |
| Weight per Piece (excluding packing) | 87.000 g |
| Custom tariff number | 85363030 |
| Country of origin | US (United States) |
| Degree of protection | IP20 |
|---|---|
| IP20 | |
| Ambient temperature (operation) | -40 °C ... 80 °C |
| Altitude | max. 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % |
| Shock (operation) | 25g |
| Vibration (operation) | 5g |
| IEC test classification | I / II |
|---|---|
| T1 / T2 | |
| EN type | T1 / T2 |
| Mounting type | DIN rail: 35 mm |
| Color | black |
| Housing material | PBT |
| Degree of pollution | 2 |
| Flammability rating according to UL 94 | V0 |
| Type | Base element, DIN rail mounting |
| Number of positions | 1 |
| Surge protection fault message | Remote indication contact |
| Note | For installation into a touch protected cabinet. For applications with UC> 500 V distances at the side and distances at the connection area must be minimum of 5 mm between different active parts including earthed parts. |
|---|
| Nominal frequency fN | 50 Hz (60 Hz) |
|---|---|
| Maximum continuous voltage UC | 600 V AC |
| Rated load current IL | 80 A (with serial 16mm² through wiring) |
| 80 A (with serial 16mm² through wiring) | |
| Short-circuit current rating ISCCR | 25 kA |
| Max. backup fuse with V-type through wiring | 80 A AC (gL/gG) |
| Max. backup fuse with branch wiring | 160 A (gL/gG) |
| Switching function | PDT contact |
|---|---|
| Operating voltage | 5 V AC ... 250 V AC |
| 125 V AC (UL) | |
| 30 V DC | |
| Operating current | 5 mA AC ... 1 A |
| 1 A (UL) | |
| 1 A | |
| Connection method | Screw connection |
| Screw thread | M2 |
| Tightening torque | 0.25 Nm |
| 0.25 Nm | |
| 4 lbf-in. (UL) | |
| Stripping length | 7 mm |
| Conductor cross section flexible min. | 0.14 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section solid min. | 0.14 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 (IEC) |
| 30 ... 14 (UL) |
| Connection method | Biconnect terminal blocks |
|---|---|
| Screw thread | M5 |
| Tightening torque | 3 Nm ... 4.5 Nm (UL) |
| 27 lbf-in. ... 40 lbf-in. (UL) | |
| Stripping length | 16 mm |
| Conductor cross section flexible min. | 1.5 mm² |
| Conductor cross section flexible max. | 25 mm² |
| Conductor cross section solid min. | 1.5 mm² |
| Conductor cross section solid max. | 35 mm² |
| Conductor cross section AWG | 15 ... 2 (IEC) |
| 10 ... 2 (UL) |
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |