PHOENIX CONTACT USLKG 35-IB USLKG 35-IB 0444035 PHOENIX CONTACT Ground modular terminal block View larger
Images are for illustrative purposes only. Please refer to data sheet for details

USLKG 35-IB 0444035 PHOENIX CONTACT Ground modular terminal block

USLKG 35-IB

0444035

PHOENIX CONTACT

25 Pcs.

Ground modular terminal block Ground terminal, For connection sections of 35 mm² / AWG 2 an NS 32 copper rail must be inserted... or NS 35... For connection sections >35 mm² / AWG 2 an NS 32 copper rail must be inserted... In a joint alignment with a pitch terminal of equal contour, a cover for insulation voltages > 690 V must be inserted., With internal hexagonal screws, number of connections: 2, number of poles: 1, type of connection: Screw connection, Sizing section: 35 mm², cross-section: 0.75 mm² - 50 mm², mounting class: NS 35/7.5, NS 35/15, NS 32, color: yellow-green Ground terminal, Use an NS 32... or NS 35... copper DIN rail for connection cross sections of 35 mm2/2 AWG. Use an NS 32... copper DIN rail for connection cross sections > 35 mm2/2 AWG. When aligning with a feed-through terminal block of the same shape, a cover must be used for insulation voltages > 690 V., with Allen screws, number of connections: 2, number of positions: 1, connection method: Screw connection, Rated cross section: 35 mm2, cross section: 0.75 mm2 - 50 mm2, mounting type: NS 35/7,5, NS 35/15, NS 32, color: green-yellow

Automation > Ground terminal block
Modular TBs

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
GeneralUse an NS 32... or NS 35... copper DIN rail for connection cross sections of 35 mm²/2 AWG. Use an NS 32... copper DIN rail for connection cross sections > 35 mm²/2 AWG. When aligning with a feed-through terminal block of the same shape, a cover must be used for insulation voltages > 690 V.
General
NoteWhen establishing a connection on the open housing side of a feed-through modular terminal block of the same series and size, the block must be provided with a cover if the expected insulation voltage is >320 V.
The max. load current must not be exceeded by the total current of all connected conductors.

Product properties
Product typeGround terminal block
Number of positions1
Number of connections2
Number of rows1
Data management status
Article revision05
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Electrical properties
Rated surge voltage8 kV
Maximum power dissipation for nominal condition4.06 W

Connection data
Grounding footYes
Number of connections per level2
Nominal cross section35 mm²
Level 1 above 1 below 1
Screw threadM6
NotePlease observe the current carrying capacity of the DIN rails.
Tightening torque3.2 ... 3.7 Nm
Stripping length15 mm ... 16 mm
Connection in acc. with standardIEC 60947-7-2
Conductor cross section rigid0.75 mm² ... 50 mm²
Cross section AWG18 ... 2 (converted acc. to IEC)
Conductor cross section flexible0.75 mm² ... 35 mm²
Conductor cross section, flexible [AWG]18 ... 2 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.75 mm² ... 35 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.75 mm² ... 35 mm²
Nominal cross section35 mm²
Tightening torque2.5 ... 3 Nm

Dimensions
Width15.2 mm
Height50 mm
Depth on NS 3267 mm
Depth on NS 35/7,562 mm
Depth on NS 35/1569.5 mm

Material specifications
Colorgreen-yellow
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Mechanical properties
Mechanical data
Open side panelNo

Environmental and real-life conditions
Oscillation/broadband noise
SpecificationDIN EN 50155 (VDE 0115-200):2018-05
SpectrumService life test category 2, bogie-mounted
Frequencyf1= 5 Hz to f2= 250 Hz
ASD level6.12 (m/s²)²/Hz
Acceleration3.12g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
ResultTest passed
Shocks
Pulse shapeHalf-sine
Acceleration5g
Shock duration30 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
ResultTest passed
Ambient conditions
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (operation)20 % ... 90 %
Permissible humidity (storage/transport)30 % ... 70 %

Standards and regulations
Connection in acc. with standardIEC 60947-7-2

Mounting
Mounting typeNS 35/7,5
NS 35/15
NS 32

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.