PHOENIX CONTACT UM-D37SUB/M/HC3/16DO/MR/1/MT UM- D37SUB/M/HC3/16DO/MR/1/MT 1083697 PHOENIX CONTACT 16-channel relay module (1 NOC) for Honeywell C300 out.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

UM- D37SUB/M/HC3/16DO/MR/1/MT 1083697 PHOENIX CONTACT 16-channel relay module (1 NOC) for Honeywell C300 out..

UM-D37SUB/M/HC3/16DO/MR/1/MT

1083697

PHOENIX CONTACT

1 Pcs.

16-channel relay module (1 NOC) for Honeywell C300 output modules. On the control side, the module is controlled via D-SUB 37-pos. or FLK 50-pos. A screw connection with knife disconnection is available on the field side. 16-channel relay module (1 normally open contact) for Honeywell C300 output components. The module is activated on the control side via 37-pole D-SUB or 50-pole FLK. On the field side, a screw connection with knife interrupt is available.

Automation > Interface module
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1083697
Packing unit1
GTIN4055626819198
Custom tariff number85364900

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area
NoteDo not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch.
The outputs are not suitable for switching different outer conductors.
No additional touch protection is required when using a SELV/PELV voltage (≤ 25 V AC or 60 V DC).
Against adjacent modules in the support rail direction at least one functional insulation on the output-side is complied with. If the application has higher requirements on the insulation (basic insulation or reinforced insulation), then these must be realized through suitable measures (e. g. partition plates).
Back to top

Dimensions

Width175 mm
Height127.8 mm
Depth66 mm
Back to top

Ambient conditions

Ambient temperature (operation)-15 °C ... 50 °C
Ambient temperature (storage/transport)-15 °C ... 50 °C
Maximum altitude≤ 2000 m
Degree of protectionIP00
≥ IP54 (Installation location)
Back to top

Input data

Nominal input voltage UN24 V DC
Input voltage range in reference to UN0.85 ... 1.1
Typical input current at UN9 mA
Typical response time5 ms
Typical release time7 ms
Protective circuit/componentDamping diode
Status display/channelYellow LED
Back to top

Output data

Contact type1 N/O contact
Contact materialAgSnO
Maximum switching voltage250 V AC/DC
Minimum switching voltage12 V AC/DC
Limiting continuous current4 A
Min. switching current10 mA
Interrupting rating (ohmic load) max.96 W (at 24 V DC)
20 W (at 48 V DC)
18 W (at 60 V DC)
23 W (at 110 V DC)
37 W (at 220 V DC)
1000 VA (for 250 V AC)
Back to top

General

Mechanical service life2x 107cycles
Operating mode100% operating factor
Mounting positionany
Assembly instructionsIn rows with zero spacing
Back to top

Connection data

Connection nameController level
Connection methodD-SUB pin strip
Number of connections1
Number of positions37
Back to top

Connection data 2

Connection nameField level
Connection methodScrew connection with disconnect knife
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 4 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Back to top

Connection data 3

Connection nameControl side
Connection methodFlat-ribbon cable connector in acc. with IEC 60603-13
Number of connections1
Number of positions50
Back to top

Supported controller

ControllerHONEYWELL Experion PKS C300/C-Series
- suitable I/O cardTDOB01 (non-redundant)
TDOB11 (redundant)
Back to top

Standards and Regulations

DesignationAir clearances and creepage distances, input/output
Standards/regulationsDIN EN 50178: 1998-04
Rated insulation voltage260 V
Rated surge voltage6 kV (1.2/50 μs)
InsulationReinforced insulation
Pollution degree2
Overvoltage categoryIII
DesignationAir and creepage distances, output/output
Standards/regulationsDIN EN 50178: 1998-04
Rated insulation voltage250 V AC
Rated surge voltage4 kV (Safe isolation, reinforced insulation, and 6 kV between input circuit and output contact current paths)
InsulationBasic insulation
Pollution degree2
Overvoltage categoryIII
Back to top

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 8.027141152
eCl@ss 9.027141152
Back to top

ETIM

ETIM 5.0EC002780
ETIM 6.0EC002780
ETIM 7.0EC002780
Back to top

ETIM for 1083697 PLC's (EC002780)
Feature Name Feature Value
Type of electrical connection, field-sided (EF005525) Screw connection
Type of electrical connection, control sided (EF008549) D-Sub
Number of poles (EF001391) 37
Rated voltage (EF000228) 24 V
Rated current (EF000227) 0.009 A
Depth (EF000049) 65.5 mm
Width (EF000008) 175 mm
Height (EF000040) 128 mm
Mounting method (EF000003) DIN rail (top hat rail) 35 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.