PHOENIX CONTACT UCT-WMS 3,2 (12X4) VT UCT-WMS 3,2 (12X4) VT 0830201 PHOENIX CONTACT Conductor marking collar View larger
Images are for illustrative purposes only. Please refer to data sheet for details

UCT-WMS 3,2 (12X4) VT 0830201 PHOENIX CONTACT Conductor marking collar

UCT-WMS 3,2 (12X4) VT

0830201

PHOENIX CONTACT

8 Pcs.

Conductor marking collar Conductor identification sleeve, Mat, violet, unlabeled, labelable with: TOPMARK NEO, TOPMARK LASER, BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting class: slip, for terminal width: 5.2 mm, cable diameter range: 1.5 ... 3.2 mm, usable surface: 12 x 4 mm, Number of individual indices: 55 Conductor marking collar, Sheet, violet, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER, BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: slide-on, for terminal block width: 5.2 mm, cable diameter range: 1.5 ... 3.2 mm, Number of individual labels: 55

Cables > Cable coding system
MS Material

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
GeneralCan be labeled via thermal transfer

Product properties
Product typeConductor marking
Pitch5.2 mm
TypeCard form
Marking
Number of individual labels55
Number of individual labels per row11
Identification technologyThermal transfer for sheets and cards

Dimensions
Width4.3 mm
Height5.8 mm
Length12 mm
Pitch5.2 mm
External dimensions
Outside diameter1.5 mm ... 3.2 mm

Material specifications
RoHS compliantyes
Colorviolet (RAL 4005)
MaterialPC
Flammability rating according to UL 94V0
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Componentsfree from silicone and halogen

Cable/line
External cable diameter1.5 mm ... 3.2 mm

Environmental and real-life conditions
Test for substances that would hinder coating with paint or varnish
ResultTest passed
UV resistance
SpecificationISO 4892-2:2013-03 (following)
ResultTest passed
Test duration96 h
Wipe resistance of inscriptions
SpecificationDIN EN 61010-1 (VDE 0411-1):2011-07
DIN EN 62208 (VDE 0660-511):2012-06 (in parts)
Isopropyl
[CAS No. 67-63-0]
Test passed
n-Hexane
[CAS No. 110-54-3]
Test passed
Water + Petroleum ether
[CAS No. 64742-82-1]
Test passed
Testing in a condensation changing climate in the presence of sulfur dioxide
SpecificationDIN 50018:2013-05
ResultTest passed
Climate levelAHT 1.0 S
Cycles2
Salt spray test
SpecificationDIN EN 60068-2-11:2000-02
ResultTest passed
Ambient conditions
Ambient temperature (operation)-40 °C ... 120 °C
Recommended storage conditions23 °C/50 % relative humidity. Storage in a dry and dark place in the original packaging is recommended.

Standards and regulations
Wipe resistanceDIN EN 61010-1 (VDE 0411-1)

Mounting
Mounting typeslide-on

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.